Conduit Accessories
Knock-Out Seals are designed to cover exposed knock-out holes in steel boxes and other metal enclosures. The 1/2 in. Knock-Out Seals (4-Pack) offer corrosion resistance. They are convenient and easy to use.
- Covers knock-out holes in metal enclosures
- Zinc-plated steel
- Corrosion resistant
- Designed for indoor and outdoor use
3#3 to 3#4/0 1-Hole Service Entrance Cable Straps (4-Pack) are a premier choice for securing service entrance cables. Attach to wood, masonry and more, inside or outdoors. They are corrosion resistant. They are constructed of steel.
- Secures bare solid copper wire to a working surface
- Made of steel
- Fits sizes 3#3 - 3#4/0
- Quick installation
Carlon PVC Grey 1-gang weatherproof cover. Cover is weatherproof and UV resistant. Cover is suitable for outdoor use.
- Suitable for outdoor use
- PVC construction
- Fits 1-Gang FS boxes
- UL and ETL listed for safety
- Supplied with stainless-steel mounting screws and a gasket
The 2 in. PVC Service Entrance Cap is designed for use with Schedule 40 and Schedule 80 rigid non-metallic conduit (RNC). The cap is crafted with PVC and features an extended cap for a weather-resistant termination. It also features a removable cover with plate knockouts and radius knockouts that eliminate sharp edges and wire chafing.
- For use with schedule 40 and schedule 80 RNC
- PVC construction
- Removable cover with plate knockouts
- Radius knockouts eliminate sharp edges and wire and cable chafing
- Extended cap for a weather-resistant termination
- CSA and UL listed for safety
- Easy to install on conduit risers
The 3/4 in. Knock-Out Seals (4-Pack) are used to cover exposed knock-out holes in steel boxes and other metal enclosures. Suitable for indoor and outdoor use. The seals are made with zinc-plated steel for strength.
- Covers exposed knock-out holes
- Corrosion-resistant zinc-plated steel construction
- For use in steel boxes and other metal enclosures
- Suitable for indoor and outdoor applications
Halex 1/2 in. Insulating Bushings (10-Pack) protect wires on a threaded Rigid or Intermediary Metal Conduit (IMC). They are required by the National Electrical Code (NEC). These bushings meet UL and CSA requirements.
- Use on threaded rigid or IMC conduits to protect wires
- Indoor/outdoor use
- Made from high-impact thermoplastic that is flame retardant to 105 degree C
- UL and CSA Listed
- Required by the NEC
12/2 to 14/2 1-Hole Service Entrance Cable Straps (10-Pack) are a premier choice for securing service entrance cables. Attach to wood, masonry and more, inside or outdoors. They are corrosion resistant.
- Secure service entrance cables (SEU and SER) to wood, masonry or similar surfaces
- Zinc-plated, galvanized steel resists corrosion
- For indoor or outdoor applications
- Designed for quick, easy installation
The 3/8 in. - 1/2 in. Conduit and Pipe Hangers (5-Pack) with speed threads are Designed to secure and suspend Rigid and EMT conduits from overhead supports. Bolt has a square neck for easy assembly. UL and CSA listed.
- Use to secure and suspend 3/8 in. and 1/2 in. rigid and 1/2 in. EMT conduits from overhead supports
- Indoor/outdoor use
- Zinc-plated steel construction
- Corrosion resistant
The #2 Conduit and Pipe Hangers are designed to secure and suspend 1 in. Rigid or EMT conduits to overhead supports. It is made of zinc-plated steel and resists corrosion. Intended for inside or outdoor use.
- Secure and suspend 1 in. rigid and EMT conduits from overhead supports
- Zinc-plated steel resists corrosion
- Compatible with #2 conduit
- UL and CSA safety listings
- For indoor or outdoor applications
- Bolt has a square neck for easy assembly
For securing EMT and rigid conduit to overhead supports, use these 3/4 in. Steel Conduit and Pipe Hangers (5-Pack). They feature speed thread with a square neck for easy assembly. For indoor and outdoor applications.
- Designed to secure and suspend EMT and rigid conduit from overhead supports
- Corrosion-resistant, zinc-plated steel construction
- Bolt contains square neck for easy assembly
- UL and CSA Listed
Feed wire through the Halex 2-1/4 in. Medium-Duty Porcelain Wire holder in overhead installations. Its zinc-plated lag screw is 2-1/4 in. long. This wire holder can be used inside or outdoors.
- For use in overhead services to secure incoming service entrance wires
- Made of porcelain and zinc-plated steel
- Lag screw is 2-1/4 in. L
- For indoor or outdoor applications
The #5 Conduit and Pipe Hangers are designed to secure and suspend 2 in. Rigid or EMT conduits to overhead supports. It is made of zinc-plated steel and resists corrosion. Intended for inside or outdoor use.
- Secure and suspend 2 in. rigid and EMT conduits from overhead supports
- Zinc-plated steel resists corrosion
- Compatible with #5 conduit
- UL and CSA safety listings
- For indoor or outdoor applications
- Bolt has a square neck for easy assembly
The 2 in. Watertight Connector is designed to connect SE/SEU cables to metal enclosures. It can also be used to connect UF cable to a waterproof box with a threaded hub. It is die-cast of corrosion-resistant, high-strength zinc alloy and can be used indoors or outside.
- For connecting SE/SEU and UF cables to boxes in wet environments
- Made of die-cast corrosion-resistant zinc alloy
- For indoor or outdoor use
- UL and CSA listed
Weatherproof closures are used to seal unused outlets of an outdoor electrical boxes, extension adapters, cluster covers or round splice boxes. Each bag includes 4 plugs. Made from diecast metal.
- Seal unused threaded outlets
- 4-pack
- UL Listed
- NEMA 3R compliant
The #4 Conduit and Pipe Hangers are designed to secure and suspend 1-1/2 in., Rigid conduit to overhead supports. It is made of zinc-plated steel and resists corrosion. Intended for inside or outdoor use.
- Secure and suspend 1-1/2 in. rigid conduit from overhead supports
- Zinc-plated steel resists corrosion
- Compatible with #4 conduit
- UL and CSA safety listings
- For indoor or outdoor applications
- Bolt has a square neck for easy assembly
The 2 in. Service Entrance Cap is designed for use in overhead service entrances with rigid conduit, intermediate metal conduit (IMC) or EMT conduit. The cap serves as a connecting point for the service entrance wires.
- Connects service entrance wires
- Copper-free die cast aluminum resists corrosion
- Designed for indoor or outdoor use in overhead service entrances
- Compatible with rigid conduit, EMT conduit or IMC
- UL and CSA listed for safety and peace of mind
- Clamp-on style for installation
Featured Product is a 1 1/2 in. x 5 in. nail plate. It is used to protect internal wire runs from nail punctures as defined in the NEC Article 300-4. It should be used indoors only.
- For interior use
- Protect internal wires from nail punctures
- Steel construction
- Zinc-plated finish provides corrosion resistance
- Includes 100 plates
- UL Listed
The 3#3 to 3#2 NM Cable 1-Hole Service Entrance Cable Straps (6-Pack) secure non-metallic cable to surfaces such as wood and masonry. The straps are made from zinc-plated steel for corrosion resistance. It is intended for indoor or outdoor use.
- Designed to secure service entrance cable to wood, masonry or a similar surface
- Made of zinc-plated steel for corrosion resistance
- 1-hole design for easy installation
- For indoor or outdoor use
The Halex 1-1/4 in. - 3 in. Adjustable Wire Holder is designed to be installed below the overhead service-entrance cap as a holding device for incoming service-entrance wires. It is made of porcelain reinforced with galvanized steel. It is easy to install.
- Securely holds overhead service-entrance wires
- Made of porcelain and galvanized steel
- For indoor or outdoor use
- Installs easily in minutes
The #3 Conduit and Pipe Hangers are designed to secure and suspend 1-1/4 in. Rigid or 1-1/2 in. EMT conduits to overhead supports. It is made of zinc-plated steel and resists corrosion. Intended for inside or outdoor use.
- Secure and suspend 1-1/4 in. rigid or 1-1/2 in. EMT conduit from an overhead support
- Zinc-plated steel resists corrosion
- Compatible with #3 conduit
- UL and CSA safety listings
- For indoor or outdoor applications
- Bolt has a square neck for ease of assembly
The #2-1/2 Conduit and Pipe Hangers are designed to secure and suspend 1-1/4 in. EMT conduits to overhead supports. It is made of zinc-plated steel and resists corrosion. Intended for inside or outdoor use.
- Use to secure and suspend 1-1/4 in. EMT conduit from overhead supports
- Zinc-plated steel resists corrosion
- Compatible with #2-1/2 conduit
- UL and CSA safety listings
- For indoor or outdoor applications
- Bolt has a square neck for easy assembly
- Used to hang 1 1/4 in. EMT conduit
Why Risk Damage To Internal Wire Runs? Install These 1-1/2 in. X 2-1/2 in. Nail Plates (50-Pack) to guard against accidental nail puncture. These zinc-plated steel plates are for interior use.
- Protect internal wire runs from nail punctures
- Zinc-plated steel resists corrosion
- For indoor use only
- Fast and easy installation
- Nail plates are UL Listed
Cable protector protects NMSC or raceway wires running through wood studs from accidental nail, screw or drill penetration. No fasteners needed with the cable protector. The dimension of protector is 2-9/16 in. long x 1-1/2 in. wide.
- 1/2 in. integral spikes used to mount to wood stud
- Made of pre-galvanized 0.0625 in. thick steel
- No additional hardware required
- Position protector and hammer down spurs
The 1-1/4 in. Watertight Connector is designed to connect SE/SEU cables to metal enclosures. It can also be used to connect UF cable to a waterproof box with a threaded hub. It is die-cast of corrosion-resistant, high-strength zinc alloy and can be used indoors or outside.
- For connecting SE/SEU and UF cables to boxes in wet environments
- Made of die-cast corrosion-resistant zinc alloy
- For indoor or outdoor use
- UL and CSA listed
- Corrosion resistant