Searched for "39131700"
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90° Celsius conductors
- Made in USA
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
The 3/4 in. Female Adapter can be used indoors and outdoors, it is made with PVC and is compatible with rigid non-metallic conduit (RNC), the adapter is CSA and UL Listed to help guarantee safety.
- Compatible with RNC
- For indoor and outdoor applications PVC construction
- PVC construction
- CSA and UL Listed for safety
The 2 in. Type LB Nonmetallic Conduit Body has a non-threaded body. Made of rigid PVC. Conduit is non-conductive and non-corrosive. Easy application.
- Textured lids
- Foam-in-place gasket
- Compatible with RNC-type conduits
- UL and CSA listed for safety
Use the 2 in. Non-Metallic Male Terminal Adapter to adapt Sch. 40 and Sch. 80 rigid non-metallic conduit to threaded fittings and metallic systems. Non-metallic PVC resists corrosion, rust, impact and damage due to exposure to sunlight. The socket end attaches to a socket fitting using solvent cement.
- Adapts non-metallic conduit to threaded fittings and metallic systems
- Non-metallic PVC is heat, fire and corrosion resistant
- Designed for use with Sch. 40 and Sch. 80 non-metallic rigid conduit
- UL and CSA listed for safety and peace of mind
- Socket fitting attaches using solvent cement
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- Meets NEMA TC2 specifications
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
The 1 in. Type LB Non-Metallic Conduit Body is designed for use with rigid non-metallic conduit (RNC). It is made with non-corrosive PVC for durability and features non-threaded hubs and a textured lid with a foam-in-place gasket. The conduit body is UL Listed for safety.
- For use with RNC
- Suitable for indoor and outdoor use
- Non-corrosive PVC construction
- Non-threaded hubs
- Textured lid with foam-in-place gasket
- UL listed to help ensure safety
3/4 in. PVC non-metallic fitting can be used with sch. 40 and sch. 80 rigid non-metallic conduit (RNC). Designed for use above ground and underground as described in the NEC. fittings insure raceway integrity. Unlike metallic systems, non-metallic fittings are lighter, can be installed in less time and are easily fabricated on the job. Fittings are non-conductive assuring a safe system. Resistant to sunlight and listed for exposed or outdoor usage, Non-metallic PVC fittings are durable and will not rust or corrode.
- Can be used to join Rigid Non-Metallic Conduit (RNC)
- Compatible with schedule 40 and schedule 80 RIGID non-metallic conduit (RNC)
- For use in aboveground and underground applications as well as exposed outdoor usage
- Durable PVC construction means no rusting or corroding
- Weighing less than metallic systems means more efficient and quicker installation time
- UL listed
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
Carlon PVC elbows are for use in a non-metallic PVC conduit run when directional change is necessary. Manufactured from durable PVC, the elbows are ideal for both indoor and outdoor applications. They will not rust or corrode which is especially important in outdoor applications.
- Designed for above and below-ground applications
- Use with schedule 40 rigid non-metallic conduit
- Resists rust and corrosion
- Listed for use in exposed and outdoor usage
The 3 in. Schedule 40 Non-Metallic 90 degree Elbow has a belled end and a standard bend radius. This item is designed for both above and below ground applications. This item is also UL and ETL Listed for safety.
- Enables a 90 degree change of directions in a run of conduit
- Belled end allows for easy joining of conduit
- Compatible with Sch. 40 rigid non-metallic conduit
- Resists rust and corrosion
- Listed for exposed and outdoor usage
- UL and ETL Listed for safety
- Belled end
The 3/4 in. Flexible PVC Elbow is compatible with liquid-tight flexible non-metallic conduit (LFNC). It is made with non-corrosive PVC and neoprene for durability and can bend from 0 to 90 without losing its round shape. It features an O-ring seal for moisture-tight connections and is ETL and UL Listed to help ensure safety.
- Great for above and below-ground applications
- Resists sunlight and corrosion
- O-ring seal for moisture-tight connections
- Sunlight resistant
- ETL and UL Listed for safety
The E945 Series 1 in. Expansion Fitting compensates for length changes due to temperature variations in exposed conduit runs. The non-metallic PVC fitting has a 2-piece molded design with lubricated seals for easier movement throughout the life of the fitting. 2 O-rings prevent leakage for a reliable fit. The fitting is compatible with Sch. 40 and 80 RNC-type electrical conduits.
- Compensates for length changes due to temperature variations in exposed conduit runs
- Non-metallic PVC with lubricated seals for easier movement
- Compatible with Sch. 40 and 80 RNC-type conduits
- UL listed for safety
- Male terminator adapter ends for installation
The 1/2 in. and 3/4 in. Access Pull Elbow enables the pulling of wires through a wall to be directed in 2 separate directions. This pull elbow is compatible with rigid non-metallic conduit. Access pull point for cable in tight radius.
- Material PVC
- Color in gray
- Schedule 40 and 80 conduit
- UL E23018
The 2 in. Non-Metallic Meter Offset is a high-quality fitting designed for indoor and outdoor use. Non-metallic PVC resists rust, corrosion, impact and the damaging effects of sunlight. The meter offset features external ridges for containment in concrete and can be used with sch. 40 and sch. 80 conduit.
- Brings electrical service into a meter box
- Non-metallic PVC is heat, fire and corrosion resistant
- Compatible with sch. 40 or sch. 80 conduit
- Ridges on the outside for concrete encasement
- UL Listed for safety and peace of mind
- Socket on 1 end with threads on offset for easy installation
The 3 in. Non-Metallic Standard Coupling is a socket for joining non-metallic electrical conduits. Made from non-metallic PVC, the socket is designed for use with RNC-type Sch. 40 and Sch. 80 conduits. The socket should be attached using solvent cement (not included). UL Listed for safety.
- Joins non-metallic electrical conduits
- Non-metallic PVC for durability
- Compatible with RNC-type schedule 40 and schedule 80 conduits
- UL listed for safety
- Should be attached using solvent cement (not included)
The 1-1/2 in. Type LB Conduit Body is made of PVC and is for use with rigid non-metallic conduit (RNC). This standard fitting is suitable for indoor and outdoor environments. This conduit body has a 32 cu. in. volume.
- Made of PVC
- Compatible with rigid non-metallic conduit
- Can be used for indoor and outdoor applications
- UL and CSA Listed
The 1 in. Non-Metallic Terminal Adapter is designed for use with Sch. 40 and Sch. 80 RIGID non-metallic conduit (RNC). It features male threads at 1 end and a socket end at the other and the adapter is made with PVC. It is CSA and UL listed to help ensure safety.
- For use with schedule 40 and 80 conduit
- Material PVC
- Color gray
- UL E23018
The 1/2 in. Female Adapter is designed for use with RIGID non-metallic conduit (RNC). The adapter is crafted with PVC, works indoors and outdoors and is CSA and UL Listed to help ensure safety. It has female threads on one end, socket end on the other.
- For use indoors and outdoors
- Compatible with RNC
- PVC construction
- CSA and UL Listed for safety
Carlon PVC elbows are for use in a non-metallic PVC conduit run when directional change is necessary. Manufactured from durable PVC, the elbows are ideal for both indoor and outdoor applications. They will not rust or corrode which is especially important in outdoor applications.
- Designed for above and below-ground applications
- Use with schedule 40 rigid non-metallic conduit
- Resists rust and corrosion
- Listed for use in exposed and outdoor usage
The 3/4 in. Female Adapter can be used indoors and outdoors. It is made with PVC and is compatible with rigid non-metallic conduit (RNC). The adapter is CSA and UL Listed to help guarantee safety.
- Compatible with RNC
- For indoor and outdoor applications
- PVC construction
- CSA and UL listed for safety
The E945 Series 1/2 in. Expansion Fitting features a 2-piece molded design and is crafted with PVC for durability. Designed to compensate for length changes due to temperature variations in exposed conduit runs, it can be installed horizontally and vertically for ease of use. It is suitable for indoor and outdoor applications. The coupling is compatible with Sch. 40 and 80 RNC-type electrical conduits.
- Compensates for length changes due to temperature variations in exposed conduit runs
- Suitable for indoor and outdoor applications
- Can be used horizontally and vertically for convenience
- Compatible with Sch. 40 and 80 RNC-type conduits
- 2-O-rings to help prevent leakage
- Molded-in mid-point indicator on the piston
- 2-piece molded design with lubricated seals for easy mobility
- CSA and UL Listed for safety