Searched for "39131700"
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- This wire conduit conforms to UL651 and NEMA TC-2 standards
- PVC conduit rated for use with 90° Celsius conductors
- Made in USA
Use the 2 in. Non-Metallic Male Terminal Adapter to adapt Sch. 40 and Sch. 80 rigid non-metallic conduit to threaded fittings and metallic systems. Non-metallic PVC resists corrosion, rust, impact and damage due to exposure to sunlight. The socket end attaches to a socket fitting using solvent cement.
- Adapts non-metallic conduit to threaded fittings and metallic systems
- Non-metallic PVC is heat, fire and corrosion resistant
- Designed for use with Sch. 40 and Sch. 80 non-metallic rigid conduit
- UL and CSA listed for safety and peace of mind
- Socket fitting attaches using solvent cement
The 2 in. Type LB Nonmetallic Conduit Body has a non-threaded body. Made of rigid PVC. Conduit is non-conductive and non-corrosive. Easy application.
- Textured lids
- Foam-in-place gasket
- Compatible with RNC-type conduits
- UL and CSA listed for safety
The 2 in. Non-Metallic Meter Offset is a high-quality fitting designed for indoor and outdoor use. Non-metallic PVC resists rust, corrosion, impact and the damaging effects of sunlight. The meter offset features external ridges for containment in concrete and can be used with sch. 40 and sch. 80 conduit.
- Brings electrical service into a meter box
- Non-metallic PVC is heat, fire and corrosion resistant
- Compatible with sch. 40 or sch. 80 conduit
- Ridges on the outside for concrete encasement
- UL Listed for safety and peace of mind
- Socket on 1 end with threads on offset for easy installation
The 1-1/4 in. Type LB Non-Metallic Conduit Body is suitable for indoor and outdoor use. It is crafted with non-corrosive PVC for long-evity and is designed for use with rigid non-metallic conduit (RNC). The body features non-threaded hubs and a textured lid with a foam-in-place gasket and is CSA and UL Listed for safety.
- Made with a textured lid and foam in-place gasket
- Works well for both indoor and outdoor use
- Has a maximum operating temperature of 120 degrees F
- Non-threaded hubs
- Textured lid with foam-in-place gasket
- CSA and UL Listed to help ensure safety
Carlon PVC elbows are for use in a non-metallic PVC conduit run when directional change is necessary. Manufactured from durable PVC, the elbows are ideal for both indoor and outdoor applications. They will not rust or corrode which is especially important in outdoor applications.
- Designed for above and below-ground applications
- Use with schedule 40 rigid non-metallic conduit
- Resists rust and corrosion
- listed for use in exposed and outdoor usage
Carlon PVC elbows are for use in a non-metallic PVC conduit run when directional change is necessary. Manufactured from durable PVC, the elbows are ideal for both indoor and outdoor applications. They will not rust or corrode which is especially important in outdoor applications.
- Designed for above and below-ground applications
- Use with Sch. 40 rigid non-metallic conduit
- Resists rust and corrosion
- Listed for use in exposed and outdoor usage
The 3 in. Non-Metallic Terminal Adapter is designed for use with Sch. 40 and Sch. 80 RIGID non-metallic conduit (RNC). It is made with PVC and features male threads on 1 end and a socket head on the other. The adapter is used for adapting non-metallic conduits to threaded fittings and metallic systems.
- Compatible with Sch. 40 and Sch. 80 rigid non-metallic conduit
- 3 in. male terminal adapter
- PVC construction for durable performance
- PVC construction
- Male threads and socket head on opposite ends
- CSA and UL Listed for safety
The 3/4 in. Female Adapter can be used indoors and outdoors, it is made with PVC and is compatible with rigid non-metallic conduit (RNC), the adapter is CSA and UL Listed to help guarantee safety.
- Compatible with RNC
- For indoor and outdoor applications PVC construction
- PVC construction
- CSA and UL Listed for safety
Protect and route your wiring with durable and versatile conduits from Cantex. This Schedule 40 PVC conduit is ideal for both underground and aboveground applications. Its sturdy construction protects electrical wires from potential damage while allowing easy installation in tight spaces. The 10-foot length provides ample coverage, while the diameter accommodates standard wiring needs. This bell-ended conduit ensures seamless connections, saving time and effort. It's engineered to resist corrosion, rust, and UV sunlight and it's perfect for indoor and outdoor environments. Our electrical conduit conforms to UL651 and NEMA TC-2 standards, guaranteeing reliable performance and safety. Our conduit is ETL-listed and is rated for conductors up to 90 degrees Celsius so you can meet the demands of modern electrical projects. Proudly made in the USA, it combines quality and compliance to suit professional and DIY installations.
- Nonmetallic PVC conduit is corrosion, rust, and sunlight-resistant
- ETL listed indoor or outdoor electrical conduit
- Meets NEMA TC2 specifications
- PVC conduit rated for use with 90-degree Celsius conductors
- Made in USA
The 1/2 in. and 3/4 in. Access Pull Elbow enables the pulling of wires through a wall to be directed in 2 separate directions. This pull elbow is compatible with rigid non-metallic conduit. Access pull point for cable in tight radius.
- Material PVC
- Color in gray
- Schedule 40 and 80 conduit
- UL E23018
The 1 1/2 in. Non-Metallic Standard Coupling is designed to join Schedule 40 and Schedule 80 rigid non-metallic conduit (RNC). It is made with PVC, is CSA and UL listed to help ensure safety. This coupling should be attached using solvent cement.
- Designed to join schedule 40 and schedule 80 RNC
- Can be used indoors and outdoors
- PVC construction
- Attach using solvent cement
- CSA and UL listed for safety
Allied Tube & Conduit schedule 40 conduit is used for your electrical wiring needs. PVC Conduit provides non-metallic protection for your cables and conductors that provides good insulation without power loss or conductor heating. Allied Tube & Conduit is PVC Conduit is sunlight, corrosion, and fire resistant.
- Commercial, Industrial and Utility Usage
- Resistant to most chemicals, PVC is typically not affected by corrosive soils or salts.
- Properties of Allied PVC Conduit provide good insulation and no power loss or conductor heating.
- Properties make PVC fire resistant.
This 1-1/4 in. 45 Sch. 40 PVC Standard Radius Elbow offsets a length of conduit. The product is designed with a belled end to allow easy joining of conduit. The item is made of durable PVC.
- Bend radius standard
- Material PVC
- Schedule 40 elbow
- UL E323335
The 1-1/2 in. 45 Belled Standard-Radius Elbow works well for above and below-ground applications as described in the NEC. The elbow is crafted with Sch. 40 PVC for durability. This elbow is rated for use with 90 degree C conductors and is ETL and UL listed for safety.
- Bend radius standard
- Gray in color
- Material PVC
- UL E323335
Carlon PVC elbows are for use in a non-metallic PVC conduit run when directional change is necessary. Manufactured from durable PVC, the elbows are ideal for both indoor and outdoor applications. They will not rust or corrode which is especially important in outdoor applications.
- Designed for above and below-ground applications
- Use with schedule 40 rigid non-metallic conduit
- Resists rust and corrosion
- Listed for use in exposed and outdoor usage
The 1 in. Type LB Non-Metallic Conduit Body is designed for use with rigid non-metallic conduit (RNC). It is made with non-corrosive PVC for durability and features non-threaded hubs and a textured lid with a foam-in-place gasket. The conduit body is UL listed for safety.
- For use with RNC
- Suitable for indoor and outdoor use
- Non-corrosive PVC construction
- Non-threaded hubs
- Textured lid with foam-in-place gasket
- UL listed to help ensure safety
The E945 Series 1/2 in. Expansion Fitting features a 2-piece molded design and is crafted with PVC for durability. Designed to compensate for length changes due to temperature variations in exposed conduit runs, it can be installed horizontally and vertically for ease of use. It is suitable for indoor and outdoor applications. The coupling is compatible with Sch. 40 and 80 RNC-type electrical conduits.
- Compensates for length changes due to temperature variations in exposed conduit runs
- Suitable for indoor and outdoor applications
- Can be used horizontally and vertically for convenience
- Compatible with Sch. 40 and 80 RNC-type conduits
- 2-O-rings to help prevent leakage
- Molded-in mid-point indicator on the piston
- 2-piece molded design with lubricated seals for easy mobility
- CSA and UL Listed for safety
The E945 Series 3/4 in. Expansion Fitting is designed to compensate for length changes due to temperature variations in exposed conduit runs. It is crafted with Sch. 40 PVC for durability. The item features a 2-piece molded design and lubricated seals for easy mobility. The fitting is compatible with Sch. 40 and 80 RNC-type electrical conduits.
- Compensates for length changes due to temperature variations in exposed conduit runs
- Can be installed horizontally and vertically
- Suitable for indoor and outdoor applications
- Compatible with Sch. 40 and 80 RNC-type conduits
- CSA and UL Listed for safety
- 2 O-rings help prevent leakage
- 2-piece molded design allows for easy mobility
- Male-terminator adapter end design
The 3/4 in. Access Pull Elbow enables the pulling of wires through a wall to be directed in 2 separate directions. This pull elbow is compatible with rigid non-metallic conduit. Access pull point for cable in tight radius.
- Can pull wiring in two different directions quickly and easily
- Allows for conduit changes in direction
- Durable PVC construction will not rust or corrode
- Adapter is threaded
Carlon PVC elbows are for use in a non-metallic PVC conduit run when directional change is necessary. Manufactured from durable PVC, the elbows are ideal for both indoor and outdoor applications. They will not rust or corrode which is especially important in outdoor applications.
- Designed for above and below-ground applications
- Use with schedule 40 rigid non-metallic conduit
- Resists rust and corrosion
- Listed for use in exposed and outdoor usage
