Square D by Schneider Electric Homeline 20 Amp 1-pole Plug-on Neutral Dual Function Circuit Breaker is a space and labor saving device, engineered to meet prevailing National Electric Code requirements. This device combines two critical technologies; Combination Arc Fault protection and Ground Fault protection (class A), in a single, easy-to-install device. The National Electric Code now requires both Combination Arc Fault and Ground Fault protection on all 1-Pole, 15 Amp and 20 Amp kitchen and laundry circuits. Prior to the release of this new device, a contractor or homeowners only choice would have been to use a Combination Arc Fault circuit breaker in conjunction with an expensive, bulky Ground Fault receptacle. The new Dual Function circuit breakers help reduce cost and eliminate the hassle of using two separate devices to provide this essential protection. It's a win for contractors and homeowners alike. Designed for reliability, the Homeline Plug-on Neutral Dual Function Circuit Breaker connects directly to the neutral bar, providing a time and labor-saving installation. Several advantages from the Plug-on Neutral design are fewer connections which lead to faster installation and an innovative neutral clip eliminates pigtails which in turn frees gutter space. Like all Square D CAFI Circuit Breakers, it is integrated with time saver Diagnostics, a unique feature that provides additional circuit information and minimizes troubleshooting at the touch of a button.
- Homeline 20 Amp single-pole plug-on-neutral dual function (CAFCI and GFCI) circuit breaker
- Innovative neutral connection design leads to fewer connections and faster installation, no pigtails which frees up gutter space
- Compatible with Homeline series 4 and newer load centers only
- 120 VAC
- 10,000 AIR
- ANSI certified and UL listed
- Limited lifetime warranty
Leviton GFCI Circuit Breakers provide overload, short-circuit, and ground-fault protection and feature an all plug-on design. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired without circuit breakers installed. Branch circuit breakers can be easily plugged on at final installation. They also feature color indicators in the handle and intuitive LEDs to easily see operational status at-a-glance. For applications up to 60 Amp when using copper wire or 50 Amp when using aluminum wire.
- Simple - features an all plug-on design - no wiring to the circuit breaker
- Intuitive - color indicators in the handle to easily see operational status at-a-glance
- Approachable - contemporary aesthetic and rocker style handle are more user friendly
- Safe - exceeds UL requirements for circuit breakers, making sure it will not reset if fault protection is compromised
- Compatible only with Leviton load centers
Leviton is proud to bring the Load Center into the 21st century with a focus on improved safety and ease of installation. Thanks to its revolutionary design, all hot and neutral wires terminate at custom lugs in the panel, rather than at the circuit breaker*, which allows the entire panel to be wired at rough-in. Branch circuit breakers are simply plugged-in at final installation, increasing jobsite efficiency. Leviton Dual Function branch circuit breakers feature an intuitive color indicator in the handle, which designates operational status at-a-glance, as well as a line-side powered LED to indicate when a fault has occured, and what type of fault - arc, or ground.
- EASY - The Load Center can be wired without any breakers present
- SAFE - Reset lockout technology prevents use of compromised unit
- INTUITIVE - LEDs communicate trip condition and type of fault
- COMFORTABLE - Rocker-style switches require less force to operate
The Square D by Schneider Electric Homeline 15 Amp One-Pole GFCI circuit breaker is designed for overload and short-circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more. This breaker is compatible with Square D Homeline load centers and CSED devices. The ANSI-certified and UL-listed unit is rated for 120 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 15 Amp one-pole GFCI circuit breaker
- Plug-on design, easy to install
- Compatible with Square D Homeline breaker boxes and CSED devices with 1 space
- For installation in 120/240-Volt AC systems
- 10,000 AIR
- Limited lifetime warranty
Square D by Schneider Electric QO 20 Amp 1-pole Dual Function Circuit Breakers is a space and labor saving device, engineered to meet prevailing NEC requirements. This device combine two critical technologies; Combination Arc Fault protection and Ground Fault protection (class A), in a single, easy-to-install device. The NEC now requires both Combination Arc Fault and Ground Fault protection on all 1-Pole, 15 Amp and 20 Amp kitchen and laundry circuits. Prior to the release of this new device, a contractor or homeowner's only choice would have been to use a Combination Arc Fault circuit breaker in conjunction with an expensive, bulky Ground Fault receptacle. The new Dual Function circuit breakers help reduce cost and eliminate the hassle of using two separate devices to provide this essential protection. It's a win for contractors and homeowners alike. Like all Square D CAFI Circuit Breakers, it is integrated with time saver Diagnostics, a unique feature that provides additional circuit information and minimizes troubleshooting at the touch of a button.
- Square D QO 20 Amp Single-Pole Dual Function (CAFCI and GFCI) Circuit Breaker
- Compatible with all Square D QO breaker boxes and CSEDs
- This breaker needs 1 space in a breaker box for installation.
- 120 VAC
- 10,000 AIR
- ANSI certified and UL Listed
- Limited lifetime warranty
Siemens introduces the new simple, spacious and secure Plug-on neutral load centers with electronic breakers. The dual-function circuit breaker combines class A 5mA GFCI and combination type AFCI, protecting against both arc faults and ground faults. This, along with the new self-test feature, makes it the first in class in electrical safety for homeowners. This Dual Function circuit breaker is the same, reliable design, without the pigtail, specifically designed for the Plug-On Neutral Load Centers. Simple, Spacious, Secure. The Siemens Plug-On Neutral Combination Type AFCI breaker detects arcing faults (an unintentional arcing condition in a circuit) that standard circuit breakers are unable to detect. This AFCI circuit breaker is the same, reliable design, without the pigtail, specifically design for the Plug-On Neutral Load Centers. These breakers now only have a single load lug. The branch neutral conductor is returned to the neutral terminal bar for simpler and quicker wiring.
- Simply installs like any other breaker, now without the pigtail
- 10,000 AIC
- HACR and SWD rated
- UL Listed
Leviton GFCI Circuit Breakers provide overload, short-circuit, and ground-fault protection and feature an all plug-on design. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired without circuit breakers installed. Branch circuit breakers can be easily plugged on at final installation. They also feature color indicators in the handle and intuitive LEDs to easily see operational status at-a-glance. For applications up to 60 Amp when using copper wire or 50 Amp when using aluminum wire.
- Simple - features an all plug-on design - no wiring to the circuit breaker
- Intuitive - color indicators in the handle to easily see operational status at-a-glance
- Approachable - contemporary aesthetic and rocker style handle are more user friendly
- Safe - exceeds UL requirements for circuit breakers, making sure it will not reset if fault protection is compromised
- Compatible only with Leviton load centers
Square D by Schneider Electric Homeline 15 Amp 1-pole Plug-on Neutral Dual Function Circuit Breaker is a space and labor saving device, engineered to meet prevailing National Electric Code requirements. This device combines 2 critical technologies; Combination Arc Fault protection and ground fault protection (class A), in a single, easy-to-install device. The National Electric Code now requires both Combination Arc Fault and ground fault protection on all 1-Pole, 15 Amp and 20 Amp kitchen and laundry circuits. Prior to the release of this new device, a contractor or homeowners only choice would have been to use a Combination Arc Fault circuit breaker in conjunction with an expensive, bulky ground fault receptacle. The new dual function circuit breakers help reduce cost and eliminate the hassle of using 2 separate devices to provide this essential protection. It's a win for contractors and homeowners alike. Designed for reliability, the Homeline Plug-on Neutral Dual Function Circuit Breaker connects directly to the neutral bar, providing a time and labor-saving installation. Several advantages from the plug-on neutral design are fewer connections which lead to faster installation and an innovative neutral clip eliminates pigtails which in turn frees gutter space. Like all Square D CAFI circuit breakers, it is integrated with time saver diagnostics, a unique feature that provides additional circuit information and minimizes troubleshooting at the touch of a button.
- Square D Homeline 15 Amp Single-Pole Plug-On Neutral Dual Function (CAFCI and GFCI) Circuit Breaker
- Innovative neutral connection design leads to fewer connections and faster installation, no pigtails which frees up gutter space
- Compatible with Square D Homeline Plug on Neutral breaker boxes only
- This breaker needs 1 space in a Plug on Neutral breaker box for installation.
- 120 VAC
- 10000 AIR
- ANSI certified and UL Listed
- Limited lifetime warranty
The Dual Function Circuit Breaker combines GFCI and AFCI, protecting against both Arc Faults and Ground Faults. This, along with the new Self-Test and Lockout feature, makes it the first in class in electrical safety for homeowners. The 2014 National Electrical Code (NEC) now requires both Arc Fault and Ground Fault protection on kitchen and laundry circuits. Before the release of Dual Function Circuit Breakers, the only option to comply with this code was to pair an AFCI circuit breaker with a GFCI receptacle. The Dual Function Circuit breaker combines these 2-devices into once solution that provides both cost savings and less hassle in installation and maintenance. This is a win solution for everyone. Testing GFCI's and AFCI's monthly is a good idea that is sometimes forgotten. Underwriters Laboratories (UL) suggests that AFCI/GFCI devices be tested every 30-days after installation to ensure they are properly working. Now the new Self-Test and Lockout feature enables the Dual Function Circuit Breaker to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly if the device was tripped to prevent a ground/arc fault. This effortless system guarantees that only the best protection is given to your home always.
- Faster installation compared to installing an AFCI breaker and GFI receptacle
- Lower cost compared to AFCI breaker and GFCI receptacle
- Self-test and lockout feature as required by UL 943
- Siemens exclusive LED trip indicator pinpoints cause of trip
- HACR, SWD, 120-Volt AC rated
- Wire range: #14-#8 AWG copper or #12-#8 AWG aluminum
Square D by Schneider Electric Homeline 15 Amp 1-pole Dual Function Circuit Breaker is a space and labor saving device, engineered to meet prevailing NEC requirements. This device combines 2 critical technologies; Combination Arc Fault protection and Ground Fault protection (class A) in a single, easy-to-install device. The NEC now requires both Combination Arc Fault and Ground Fault protection on all 1-Pole, 15 Amp and 20 Amp kitchen and laundry circuits. Prior to the release of this new device, a contractor or homeowners only choice would have been to use a Combination Arc Fault circuit breaker in conjunction with an expensive, bulky ground fault receptacle. The new dual function circuit breakers help reduce cost and eliminate the hassle of using 2 separate devices to provide this essential protection. It's a win for contractors and homeowners alike. Like all Square D CAFI circuit breakers, it is integrated with time saver diagnostics, a unique feature that provides additional circuit information and minimizes troubleshooting at the touch of a button.
- Square D Homeline 15 Amp Single-Pole Dual Function (CAFCI and GFCI) Circuit Breaker
- Compatible with all Square D Homeline breaker boxes with 1 space
- 120 VAC
- 10000 AIR
- ANSI certified and UL Listed
- Limited lifetime warranty
The Square D by Schneider Electric Homeline 20 Amp Two-Pole GFCI circuit breaker is designed for overload and short-circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more. This breaker is compatible with Square D Homeline load centers and CSED devices. The ANSI-certified and UL-Listed unit is rated for 120/240 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 20 Amp two-pole GFCI circuit breaker
- Plug-on design, easy to install
- Compatible with Square D Homeline breaker boxes and CSED devices
- For installation in 120/240-Volt AC systems
- 10,000 AIR
- Limited lifetime warranty
Leviton is proud to bring the Load Center into the 21st century with a focus on improved safety and ease of installation. Thanks to its revolutionary design, all hot and neutral wires terminate at custom lugs in the panel, rather than at the circuit breaker*, which allows the entire panel to be wired at rough-in. Branch circuit breakers are simply plugged-in at final installation, increasing jobsite efficiency. The Leviton Load Center with smart circuit breakers is the industry's most intellegent residential circuit breaker system, offering powerful analytics and alerts, real-time energy consumption data, and the ability to remotely turn off individual circuits from anwhere.
- SMART - See energy data and breaker status in the My Leviton app
- EASY - The Load Center can be wired without any breakers present
- HYDRAULIC MAGNETIC - Operates as intended from -40°F to 185°F
- SAFE - Reset lockout technology prevents use of compromised unit
Eaton's BR ground fault current interrupters (GFCIs) are 1 in. W and provide superior safety over a standard electrical outlet in areas where electricity may come into contact with water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution. This circuit breaker periodically runs a self-test diagnostic and complies UL 943, 4th Edition.
- Amperage: 30 Amp
- Self-test GFCI
- For use in type BR load centers
- Interrupt rating-10 kAIC
Siemens introduces the new simple, spacious and secure Plug-on neutral load centers with electronic breakers. The Ground fault (GFCI) circuit breaker are an effective means of preventing severe electrical shock. GFCIs are installed to protect areas of the home, such as the kitchen, bathroom or laundry, where electrical appliances or products may come into contact with water. This Ground Fault circuit breaker is the same, reliable design, without the pigtail, specifically designed for the Plug-On Neutral Load Centers.
- Simply installs like any other breaker, now without the pigtail
- 10,000 AIC
- UL listed
- HACR and SWD rated
The Dual Function Circuit Breaker combines GFCI and AFCI, protecting against both Arc Faults and Ground Faults, this, along with the new Self-Test and Lockout feature, makes it the first in class in electrical safety for homeowners, the 2014 National Electrical Code (NEC) now requires both Arc Fault and Ground Fault protection on kitchen and laundry circuits. Before the release of Dual Function Circuit Breakers, the only option to comply with this code was to pair an AFCI circuit breaker with a GFCI receptacle, the Dual Function Circuit breaker combines these 2-devices into once solution that provides both cost savings and less hassle in installation and maintenance, this is a win solution for everyone. Testing GFCI's and AFCI's monthly is a good idea that is sometimes forgotten. Underwriters Laboratories (UL) suggests that AFCI/GFCI devices be tested every 30-days after installation to ensure they are properly working. Now the new Self-Test and Lockout feature enables the Dual Function Circuit Breaker to automatically and continuously test itself to ensure that it is working properly, if it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly if the device was tripped to prevent a ground/arc fault, this effortless system guarantees that only the best protection is given to your home always.
- Faster installation compared to installing an AFCI breaker and GFI receptacle
- Lower cost compared to AFCI breaker and GFCI receptacle
- Self-test and lockout feature as required by UL 943
- Siemens exclusive LED trip indicator pinpoints cause of trip
- HACR, SWD, 120-Volt AC rated
- Wire range: #14-#8 AWG copper or #12-#8 AWG aluminum
Square D by Schneider Electric Homeline 20 Amp 1-pole Dual Function Circuit Breaker is a space and labor saving device, engineered to meet prevailing National Electric Code requirements. This device combines 2 critical technologies; Combination Arc Fault protection and ground fault protection (class A) in a single, easy-to-install device. The National Electric Code now requires both Combination Arc Fault and ground fault protection on all 1-Pole, 15 Amp and 20 Amp kitchen and laundry circuits. Prior to the release of this new device, a contractor or homeowners only choice would have been to use a Combination Arc Fault circuit breaker in conjunction with an expensive, bulky ground fault receptacle. The new dual function circuit breakers help reduce cost and eliminate the hassle of using 2 separate devices to provide this essential protection. It's a win for contractors and homeowners alike. Like all Square D CAFI circuit breakers, it is integrated with time saver diagnostics, a unique feature that provides additional circuit information and minimizes troubleshooting at the touch of a button.
- Square D Homeline 20 Amp Single-Pole Dual Function (CAFCI and GFCI) Circuit Breaker
- Compatible with all Square D Homeline breaker boxes
- This breaker needs 1 space in a breaker box for installation.
- 120 VAC
- 10000 AIR
- ANSI certified and UL Listed
- Limited lifetime warranty
The Square D by Schneider Electric Homeline 20 Amp One-Pole GFCI circuit breaker is designed for overload and short-circuits protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 Milli Amperes or more. This breaker is compatible with Homeline load centers and CSED devices. The ANSI-certified and UL-listed unit is rated for 120-Volt AC and 10,000 Air. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 20 Amp 1-pole GFCI circuit breaker
- Plug-on design, easy to install
- Compatible with Square D Homeline breaker boxes and CSED devices
- This breaker needs 1 space in a breaker box for installation
- 120-Volt AC
- 10,000 AIR
- Limited lifetime warranty
Siemens GFCI circuit breakers are UL Listed and CSA Certified as Class A devices. These circuit breakers offer the new Self-Test and Lockout feature as required by UL 943, enabling the GFCI to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground fault.
- Double-pole, 240-Volt, 50 Amp GFCI circuit breaker
- 10 kA interrupting rating
- Includes self-test as required by UL 943 as an added safety feature
- Suitable for a variety of construction applications including spas, hot tubs, kitchens, bathrooms, etc.
Siemens GFCI circuit breakers are UL Listed and CSA Certified as Class A devices. These circuit breakers offer the new Self-Test and Lockout feature as required by UL 943, enabling the GFCI to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground fault.
- Single pole, 120-Volt, 20 Amp GFCI circuit breaker
- 10kA interrupting rating
- Includes self-test as required by UL 943 as an added safety feature
- Suitable for a variety of construction applications including spas, hot tubs, kitchens, bathrooms, etc.
Siemens GFCI circuit breakers are UL Listed and CSA Certified as Class A devices. These circuit breakers offer the new Self-Test and Lockout feature as required by UL 943, enabling the GFCI to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground fault.
- Double pole, 240-Volt, 20 Amp GFCI circuit breaker
- 10kA interrupting rating
- Includes self-test as required by UL 943 as an added safety feature
- Suitable for a variety of construction applications including spas, hot tubs, kitchens, bathrooms, etc.
The 2014 NEC has mandated Ground Fault and Arc Fault circuit protection on many 15 Amp and 20 Amp kitchen and laundry circuits. General Electric offers both Ground Fault and Combination Arc Fault (GFCI and CAFCI) protection in a simple to apply and cost effective solution. GFCI protection guards against ground fault as an effective means of preventing electrical shocks. GFCI circuit breakers accomplish this by detecting when current is "leaking" somewhere outside its intended path. If your body provides path to ground for this "leakage" you could be burned, shocked or even electrocuted. CAFCI protection guards against damage or fires which can result from arcing and sparking that can arise from deteriorated wires, poor connections and breaches in wire insulation. With more than 67,000 home fires claiming more than 485 lives and injuring 2,300 victims annually, the added safety provided by CAFCI protection is an important step forward in reducing this risk.
- GE DFCI has important features for assisting you or your electrician in troubleshooting a trip, should the DFCI trip, the yellow LED will blink to indicate the last known trip condition
- Indicates the last known trip condition by illuminating LED appearing for 5-seconds each time the DFCI is turned on for up to 30-days
- Units last known trip condition can be cleared by performing a series of functions provided in the instructions
- DFCI has a self-test feature that meets a June 2015 requirement from UL on all ground fault circuit breakers
- Must be used with a dedicated neutral can't be used with a shared neutral
Leviton is proud to bring the Load Center into the 21st century with a focus on improved safety and ease of installation. Thanks to its revolutionary design, all hot and neutral wires terminate at custom lugs in the panel, rather than at the circuit breaker*, which allows the entire panel to be wired at rough-in. Branch circuit breakers are simply plugged-in at final installation, increasing jobsite efficiency. Leviton Dual Function branch circuit breakers feature an intuitive color indicator in the handle, which designates operational status at-a-glance, as well as a line-side powered LED to indicate when a fault has occured, and what type of fault - arc, or ground.
- EASY - The Load Center can be wired without any breakers present
- SAFE - Reset lockout technology prevents use of compromised unit
- INTUITIVE - LEDs communicate trip condition and type of fault
- COMFORTABLE - Rocker-style switches require less force to operate
Siemens GFCI circuit breakers are UL Listed and CSA Certified as Class A devices. These circuit breakers offer the new Self-Test and Lockout feature as required by UL 943, enabling the GFCI to automatically and continuously test itself to ensure that it is working properly. If it is detected that the device has been compromised, the device trips itself and locks out the homeowner from resetting the device, reducing the possibility of the homeowner incorrectly assuming that the device was tripped to prevent a ground fault.
- Single pole, 120-Volt, 15 Amp GFCI circuit breaker
- 10kA interrupting rating
- Includes self-test as required by UL 943 as an added safety feature
- Suitable for a variety of construction applications including spas, hot tubs, kitchens, bathrooms, etc.
The 2014 NEC has mandated Ground Fault and Arc Fault circuit protection on many 15 Amp and 20 Amp kitchen and laundry circuits. General Electric offers both Ground Fault and Combination Arc Fault (GFCI and CAFCI) protection in a simple to apply and cost effective solution. GFCI protection guards against ground fault as an effective means of preventing electrical shocks. GFCI circuit breakers accomplish this by detecting when current is "leaking" somewhere outside its intended path. If your body provides path to ground for this "leakage" you could be burned, shocked or even electrocuted. CAFCI protection guards against damage or fires which can result from arcing and sparking that can arise from deteriorated wires, poor connections and breaches in wire insulation. With more than 67,000 home fires claiming more than 485 lives and injuring 2,300 victims annually, the added safety provided by CAFCI protection is an important step forward in reducing this risk.
- GE DFCI has important features for assisting you or your electrician in troubleshooting a trip, should the DFCI trip, the yellow LED will blink to indicate the last known trip condition
- Indicates the last known trip condition by illuminating LED appearing for 5-seconds each time the DFCI is turned on for up to 30-days
- Units last known trip condition can be cleared by performing a series of functions provided in the instructions
- DFCI has a self-test feature that meets a June 2015 requirement from UL on all ground fault circuit breakers
- Must be used with a dedicated neutral can't be used with a shared neutral
General Electric Ground Fault Circuit Interrupter
- 120/240 Vac
- 20A
- HACR Rated
- Requires One 1" Space
- Single Pole
- Mfg #THQL-1120GFI
- 120/240 Vac
- 20A
- HACR Rated
- Requires One 1" Space
Leviton GFCI Circuit Breakers provide overload, short-circuit, and ground-fault protection and feature an all plug-on design. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired without circuit breakers installed. Branch circuit breakers can be easily plugged on at final installation. They also feature color indicators in the handle and intuitive LEDs to easily see operational status at-a-glance. For applications up to 60 Amp when using copper wire or 50 Amp when using aluminum wire.
- Simple - features an all plug-on design - no wiring to the circuit breaker
- Intuitive - color indicators in the handle to easily see operational status at-a-glance
- Approachable - contemporary aesthetic and rocker style handle are more user friendly
- Safe - exceeds UL requirements for circuit breakers, making sure it will not reset if fault protection is compromised
- Compatible only with Leviton load centers
Siemens introduces the new simple, spacious and secure Plug-on neutral load centers with electronic breakers. The Ground fault (GFCI) circuit breaks are an effective means of preventing severe electrical shock. GFCIs are installed to protect areas of the home, such as the kitchen, bathroom or laundry, where electrical appliances or products may come into contact with water. This Ground Fault circuit breaker is the same, reliable design, without the pigtail, specifically designed for the Plug-On Neutral Load Centers.
- Simply installs like any other breaker, now without the pigtail
- 10,000 AIC
- HACR and SWD rated
- UL Listed
Siemens introduces the new simple, spacious and secure Plug-on neutral load centers with electronic breakers. The Ground fault (GFCI) circuit breaks are an effective means of preventing severe electrical shock. GFCIs are installed to protect areas of the home, such as the kitchen, bathroom or laundry, where electrical appliances or products may come into contact with water. This Ground Fault circuit breaker is the same, reliable design, without the pigtail, specifically designed for the Plug-On Neutral Load Centers.
- Simply installs like any other breaker, now without the pigtail
- 10,000 AIC
- HACR and SWD rated
- UL Listed
Siemens introduces the new simple, spacious and secure Plug-on neutral load centers with electronic breakers. The dual-function circuit breaker combines class A 5mA GFCI and combination type AFCI, protecting against both arc faults and ground faults. This, along with the new self-test feature, makes it the first in class in electrical safety for homeowners. This Dual Function circuit breaker is the same, reliable design, without the pigtail, specifically designed for the Plug-On Neutral Load Centers.
- Simply installs like any other breaker, now without the pigtail
- 10,000 AIC
- HACR and SWD rated
- UL Listed
The Square D by Schneider Electric Homeline 50 Amp Two-Pole GFCI circuit breaker is designed for overload and short-circuit protection, combined with Class A ground fault protection. Class A denotes a ground fault circuit interrupter that will trip when a fault current to ground is 6 mA or more. This breaker is compatible with Square D Homeline load centers and CSED devices. The ANSI-certified and UL-Listed unit is rated for 120/240 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 50 Amp two-pole GFCI circuit breaker
- Plug-on design, easy to install
- Compatible with Square D Homeline breaker boxes and CSED devices with 2 spaces
- For installation in 120/240-Volt AC systems
- 10,000 AIR
- ANSI certified and UL Listed
- Limited lifetime warranty
The Square D by Schneider Electric QO Qwik-Gard 20 Amp One-Pole GFCI Circuit Breaker is intended for protection of entire branch circuits where damp-location shock hazards may exist, providing overload and short-circuit protection of your electrical system. The ANSI-certified and UL-listed unit is rated for 120 VAC and 10,000 AIR. All QO circuit breakers are equipped with the exclusive Visi-Trip indicator. When a QO Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between in OFF and in ON and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 42 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection. This QO Qwik-Gard breaker is compatible with Square D's QO breaker box and CSEDs with 1 space available.
- Square D QO Qwik-Gard 20 Amp single-pole GFCI circuit breaker
- Plug-on design, easy to install
- Compatible with Square D QO breaker boxes, CSED's and NQOD panel boards with 1 space
- 120-Volt AC
- 10,000 AIR
- Limited lifetime warranty
Leviton 20A AFCI/GFCI Dual Function Branch Circuit Breaker, 1 Pole Safe – Leviton Gfci, Afci And Dual-Function Circuit Breakers Feature Patented Reset Lockout Technology, And Will Not Reset If Ground Or Arc Fault Protection Is Comprimised EASY – Leviton's revolutionary design allows the entire Load Center to be wired at rough-in without any circuit breakers present Mfg #R27-LB120-SDR
- Safe – Leviton Gfci, Afci And Dual-Function Circuit Breakers
- EASY – Leviton's revolutionary design allows the entire Load Center to be wired at rough-in without any circuit breakers present
- Feature Patented Reset Lockout Technology, And Will Not Reset If Ground Or Arc Fault Protection Is Comprimised
- R27-LB120-SDR
Eaton's Classified Circuit Breakers deliver on safe installation and reliable operation. Eaton Classified replacement Circuit Breakers are available in both 3/4-inch Type CHQ and 1-inch Type CL, single- and two-pole configurations. These breakers are UL-listed and designed to be used in loadcenters made by other manufacturers.Eatons CL GFCI circuit breakers provide protection for people from hazards of electrical shock in areas where electricity may meet water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs, outdoor receptacles, etc.
- Eaton Classified Breakers meet or exceed relevant codes and standards and are rigorously tested and listed by UL
- Compatible with loadcenters produced by General Electric, Siemens, Murray, Square D and other manufacturers
- It is important to know that Classified Circuit Breakers are for use with panelboards rated 225 amperes, are limited to 120/40 volt applications and the available short circuit rating cannot exceed 10 kilo-amperes
- Eaton Classified Circuit Breakers are UL listed, so the original manufacturer's warranty would still be effective when you apply our technology within applicable loadcenters
Eaton's BR Ground Fault Current Interrupters (GFCIs) are 1 in. wide and provide superior safety over a standard electrical outlet in areas where electricity may meet water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution. This circuit breaker periodically runs a self-test diagnostic and complies UL 943, Fourth Edition.
- Amperage rating: 20 Amp
- Self-test GFCI
- For use in type BR load centers
- Interrupt rating-10 kAIC
1 Pole 15 Amp Bolt On Ground Fault. Mfg #THQB1115GFT
- Thqb Series Breaker
- Bolt-On
- Single Pole
- 120/240 Vac
Eaton's BR Ground Fault Current Interrupters (GFCIs) are 1 in. wide and provide superior safety over a standard electrical outlet in areas where electricity may meet water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution. This circuit breaker periodically runs a self-test diagnostic and complies UL 943, Fourth Edition.
- Amperage: 15 Amp
- Self-test GFCI
- For use in type BR load centers
- Interrupt rating-10 kAIC
1 Pole 20 Amp Bolt On Ground Fault. Mfg #THQB1120GFT
- Thqb Series Breaker
- Bolt-On
- Single Pole
- 120/240 Vac
Eaton's Classified Circuit Breakers deliver on safe installation and reliable operation. Eaton Classified replacement Circuit Breakers are available in both 3/4-inch Type CHQ and 1-inch Type CL, single- and two-pole configurations. These breakers are UL-listed and designed to be used in loadcenters made by other manufacturers.Eatons CL GFCI circuit breakers provide protection for people from hazards of electrical shock in areas where electricity may meet water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs, outdoor receptacles, etc.
- Eaton Classified Breakers meet or exceed relevant codes and standards and are rigorously tested and listed by UL
- Compatible with loadcenters produced by General Electric, Siemens, Murray, Square D and other manufacturers
- It is important to know that Classified Circuit Breakers are for use with panelboards rated 225 amperes, are limited to 120/40 volt applications and the available short circuit rating cannot exceed 10 kilo-amperes
- Eaton Classified Circuit Breakers are UL listed, so the original manufacturer's warranty would still be effective when you apply our technology within applicable loadcenters