Circuit Breakers

Category
Brand
Breaker Type
Certifications and Listings
Number of Poles
Number of Spaces
Pack Size
Product Depth (in.)
Product Height (in.)
Product Width (in.)
Other Refinements
Items per page: 24   48  
Sort By:
Siemens Triplex 2-Outer 20 Amp Single-Pole and 1-Inner 30 Amp Double-Pole Circuit Breaker
Siemens Triplex 2-Outer 20 Amp Single-Pole and 1-Inner 30 Amp Double-Pole Circuit Breaker
Item # 793294
UL Underwriters Laboratories (USA and Canada)

Siemens Triplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Triplex Circuit Breaker provides overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.

  • (1) 30 amp double pole and (2) 20 amp single pole circuit breakers
  • Requires 2 in. breaker space
  • Plug in type
  • Space saving design allows 2 poles to fit in a 1 in. panel space
  • 10K AIC series rating
  • 120/240 VAC
  • UL listed
  • CSA certified
  • HACR rated
  • Designed for residential/commercial applications

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 1-20 Amp 2 Pole and 1-30 Amp 2 Pole BQ (Independent Trip) Quad Circuit Breaker
Eaton BR 1-20 Amp 2 Pole and 1-30 Amp 2 Pole BQ (Independent Trip) Quad Circuit Breaker
Item # 457072
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger, and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - (1) 2 pole 20 Amp and (1) 2 pole 30 Amp
  • Number of poles - 4
  • Trip type - independent
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240V
  • Wire size - #14-4 AWG Cu/Al at 60C or 75C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 2-30 Amp 2 Pole BQ (Independent Trip) Quad Circuit Breaker
Eaton BR 2-30 Amp 2 Pole BQ (Independent Trip) Quad Circuit Breaker
Item # 457073
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger, and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - (2) 2 pole 30 Amp
  • Number of poles - 4
  • Trip type - independent
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240V
  • Wire size - #14-4 AWG Cu/Al at 60C or 75C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Siemens Quadplex 1-Outer 30 Amp Double-Pole and 1-Inner 30 Amp Double-Pole Circuit Breaker
Siemens Quadplex 1-Outer 30 Amp Double-Pole and 1-Inner 30 Amp Double-Pole Circuit Breaker
Item # 778161
UL Underwriters Laboratories (USA and Canada)

Siemens Quadplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Quadplex Circuit Breakers provide overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Quad breakers provide two sets of common trip, 2-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.

  • Quad breakers provide two sets of common trip, 2-pole breakers
  • 1) 30-Amp Double Pole and (1) 30-Amp Double Pole
  • Compatible with Siemens panels that allow CTL type QT breakers
  • Plug-in design enables hassle-free installation
  • Requires 2 inch breaker space
  • Meets UL, CSA and ANSI safety requirement. SWD and HACR Rated
  • Designed to protect the home's wiring from high temperatures caused by excess current

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Pushmatic New UBIP 30 Amp 2-Pole Pushmatic Replacement Circuit Breaker
Pushmatic New UBIP 30 Amp 2-Pole Pushmatic Replacement Circuit Breaker
Item # 607632

Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.

  • Pushmatic Replacement Breaker : P230
  • 2 Pole breaker in 1- ½" body
  • Intertek ETL Listing to UL Standard 489 for US and Canada - Molded case circuit breakers
  • Manufactured New by Connecticut Electric
  • Bolt On Type
  • 30 AMP - 120/240 VAC - 10,000 AIC
  • May also be branded as Bulldog (i.e. Bulldog P230)

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Siemens 200 Amp Main Breaker Conversion Kit
Siemens 200 Amp Main Breaker Conversion Kit
Item # 457059
UL Underwriters Laboratories (USA and Canada)

This 200 Amp Double-Pole Main Breaker Conversion Kit is designed to convert a main lug load center into a main breaker load center. The breaker has a maximum load of 240-Volt and is suitable for use in 200 Amp load centers. This ANSI-certified and CSA and UL-listed converter is compatible for use in both Murray and Siemens' Ultimate Load Centers. Allows for a means of disconnect in a single switch for all circuits in your Siemens Load Center.

  • Use to convert a main lug load center to a main breaker load center
  • Bolt on main breaker designed for use in ultimate load centers
  • Interrupting rating of 22KA 120/240V AC
  • ANSI certified and CSA and UL listed

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Pushmatic New UBIP 20 Amp 2-Pole Pushmatic Replacement Circuit Breaker
Pushmatic New UBIP 20 Amp 2-Pole Pushmatic Replacement Circuit Breaker
Item # 607620

Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.

  • Pushmatic Replacement Breaker : P220
  • 2 Pole breaker in 1- ½" body
  • Intertek ETL Listing to UL Standard 489 for US and Canada - Molded case circuit breakers
  • Manufactured New by Connecticut Electric
  • Bolt On Type
  • 20 AMP - 120/240 VAC - 10,000 AIC
  • May also be branded as Bulldog (i.e. Bulldog P220)

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Siemens Triplex 2-Outer 20 Amp Single-Pole and 1-Inner 50 Amp Double-Pole Circuit Breaker
Siemens Triplex 2-Outer 20 Amp Single-Pole and 1-Inner 50 Amp Double-Pole Circuit Breaker
Item # 778159

Siemens Triplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Triplex Circuit Breaker provides overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.

  • (1) 50 amp double pole and (2) 20 amp single pole circuit breakers
  • Requires 2 in. breaker space
  • Plug in type
  • Space saving design allows 2 poles to fit in a 1 in. panel space
  • 10K AIC series rating
  • Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers
  • UL listed
  • CSA certified
  • HACR rated
  • Designed for residential/commercial applications

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 1-40 Amp 2 Pole and 2-20 Amp 1 Pole BQ (Independent Trip) Quad Circuit Breaker
Eaton BR 1-40 Amp 2 Pole and 2-20 Amp 1 Pole BQ (Independent Trip) Quad Circuit Breaker
Item # 457071
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - (2) 1-pole 20 Amp and (1) 2-pole 40 Amp
  • Number of poles - 4
  • Trip type - independent
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240-Volt at 40 Amp, 120-Volt at 20 Amp
  • Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 1- 50 Amp 2-Pole and 2-20 Amp 1 Pole BQC (Common Trip) Quad Circuit Breaker
Eaton BR 1- 50 Amp 2-Pole and 2-20 Amp 1 Pole BQC (Common Trip) Quad Circuit Breaker
Item # 457050
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - 2 - single-pole 20 Amp, one 2-pole 50 Amp
  • Number of poles - 4
  • Trip type - common
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240-Volt
  • Wire size - #14-4 AWG Cu/Al at 60C or 75C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Siemens Triplex 2-Outer 15 Amp Single-Pole and 1-Inner 30 Amp Double-Pole Circuit Breaker
Siemens Triplex 2-Outer 15 Amp Single-Pole and 1-Inner 30 Amp Double-Pole Circuit Breaker
Item # 778160
UL Underwriters Laboratories (USA and Canada)

Siemens Triplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Triplex Circuit Breaker provides overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.

  • (1) 30 Amp Double Pole and (2) 15 Amp Single Pole Circuit Breakers
  • Requires 2 inch breaker space
  • 10,000 AIC rated
  • Space saving design allows 2 poles to fit in a 1 in. panel space
  • 10K AIC series rating
  • 120/240 VAC
  • UL listed
  • CSA certified
  • HACR rated
  • Designed for residential/commercial applications

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Siemens 150 Amp Main Breaker Conversion Kit
Siemens 150 Amp Main Breaker Conversion Kit
Item # 793307
UL Underwriters Laboratories (USA and Canada)

This 150 Amp Double-Pole Main Breaker Conversion Kit is designed to convert a main lug load center into a main breaker load center. The breaker has a maximum load of 240-Volt and is suitable for use in 150 Amp load centers. This ANSI-certified and CSA and UL-listed converter is compatible for use in both Murray and Siemens' Ultimate Load Centers. Allows for a means of disconnect in a single switch for all circuits in your Siemens Load Center.

  • Use to convert a main lug load center to a main breaker load center
  • Bolt on main breaker designed for use in ultimate load centers
  • Interrupting rating of 22KA 120/240V AC
  • Wire range #1 - 300 kcmil cu/al
  • ANSI certified and CSA and UL listed

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 1-20 Amp 2 Pole and 1-30 Amp 2 Pole BQC (Common Trip) Quad Circuit Breaker
Eaton BR 1-20 Amp 2 Pole and 1-30 Amp 2 Pole BQC (Common Trip) Quad Circuit Breaker
Item # 457051
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - (1) 2-pole 20 Amp and (1) 2-pole 30 Amp
  • Number of poles - 4
  • Trip type - common
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240-Volt
  • Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Murray 20 Amp Single-Pole Type MP-Circuit Breaker
Murray 20 Amp Single-Pole Type MP-Circuit Breaker
Item # 783904
UL Underwriters Laboratories (USA and Canada)

Murray offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Murray offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.

  • Single pole, 20 Amp 120-Volt type MP circuit breaker
  • 10,000 AIC interrupting rating
  • Murray type MP circuit breakers provide easy plug-in connections in Murray enclosures and the time saving insta-wire feature
  • Compatible with Murray rock solid load centers
  • Use for overload and short-circuit protection of your electrical system
  • Thermal-magnetic
  • Provides a manual means of energizing and de-energizing a circuit
  • Easy plug in connections in Murray load centers

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 1-30 Amp 2 Pole and 2-20 Amp 1 Pole BQ (Independent Trip) Quad Circuit Breaker
Eaton BR 1-30 Amp 2 Pole and 2-20 Amp 1 Pole BQ (Independent Trip) Quad Circuit Breaker
Item # 457070
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - (2) 1-pole 20 Amp and (1) 2-pole 30 Amp
  • Number of poles - 4
  • Trip type - independent
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240-Volt at 30 Amp, 120-Volt at 20 Amp
  • Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 1-30 Amp 2 Pole and 1-50 Amp 2 Pole BQ (Independent Trip) Quad Circuit Breaker
Eaton BR 1-30 Amp 2 Pole and 1-50 Amp 2 Pole BQ (Independent Trip) Quad Circuit Breaker
Item # 457074
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger, and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - (1) 2 pole 30 Amp and (1) 2 pole 50 Amp
  • Number of poles - 4
  • Trip type - independent
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240V
  • Wire size - #14-4 AWG Cu/Al at 60C or 75C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Siemens Quadplex One Outer 50 Amp Double-Pole and One Inner 30 Amp Double-Pole-Circuit Breaker
Siemens Quadplex One Outer 50 Amp Double-Pole and One Inner 30 Amp Double-Pole-Circuit Breaker
Item # 778162

Siemens Quadplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Quadplex Circuit Breakers provide overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Quad breakers provide two sets of common trip, 2-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.

  • Quad breakers provide 2-sets of common trip, 2-pole breakers
  • (1) 30 amp double pole and (1) 50 amp double pole
  • Compatible with siemens panels that allow CTL type QT breakers
  • Plug-in design enables hassle-free installation
  • Requires 2 in. breaker space
  • Meets UL, CSA and ANSI safety requirement. SWD and HACR rated
  • Designed to protect the home's wiring from high temperatures caused by excess current

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Pushmatic New UBIP Twin 20 Amp/20 Amp 1-Pole Pushmatic Replacement Circuit Breaker
Pushmatic New UBIP Twin 20 Amp/20 Amp 1-Pole Pushmatic Replacement Circuit Breaker
Item # 607536

Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.

  • Pushmatic Replacement Breaker : P2020
  • 2 - 1 Pole breakers in 1- ½" body
  • Intertek ETL Listing to UL standard 489 for US and Canada-molded case circuit breakers
  • Manufactured New by Connecticut Electric
  • Bolt On Type
  • 20/20 AMP - 120 VAC - 10,000 AIC
  • May also be branded as Bulldog (i.e. Bulldog P2020)
  • Class CTL circuit breaker for use in CTL listed panels

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Pushmatic New UBIP 20 Amp 1-Pole Pushmatic Replacement Circuit Breaker
Pushmatic New UBIP 20 Amp 1-Pole Pushmatic Replacement Circuit Breaker
Item # 607520

Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished circuit breakers should never be used.

  • Pushmatic Replacement Breaker : P120
  • 1 Pole breaker in 1- ½" body
  • Intertek ETL Listing to UL Standard 489 for US and Canada - Molded case circuit breakers
  • Manufactured New by Connecticut Electric
  • Bolt On Type
  • 20 AMP - 120 VAC - 10,000 AIC
  • May also be branded as Bulldog (i.e., Bulldog P120)

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Pushmatic New UBIP Twin 15 Amp/15 Amp 1-Pole Pushmatic Replacement Circuit Breaker
Pushmatic New UBIP Twin 15 Amp/15 Amp 1-Pole Pushmatic Replacement Circuit Breaker
Item # 607535

Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.

  • Pushmatic Replacement Breaker : P1515
  • 2 - 1 Pole breakers in 1- ½" body
  • Intertek ETL Listing to UL standard 489 for US and Canada-molded case circuit breakers
  • Manufactured New by Connecticut Electric
  • Bolt On Type
  • 15/15 AMP - 120 VAC - 10,000 AIC
  • May also be branded as Bulldog (i.e. Bulldog P2020)
  • Class CTL circuit breaker for use in CTL listed panels

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 1-30 Amp 2 Pole and 1-40 Amp 2 Pole BQC (Common Trip) Quad Circuit Breaker
Eaton BR 1-30 Amp 2 Pole and 1-40 Amp 2 Pole BQC (Common Trip) Quad Circuit Breaker
Item # 457053
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - (1) 2-pole 30 Amp and (1) 2-pole 40 Amp
  • Number of poles - 4
  • Trip type - common
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240-Volt
  • Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Siemens 100 Amp Main Breaker Conversion Kit
Siemens 100 Amp Main Breaker Conversion Kit
Item # 457058
UL Underwriters Laboratories (USA and Canada)

This 100 Amp Double-Pole Main Breaker Conversion Kit is designed to convert a main lug load center to a main breaker load center. The breaker has a maximum load of 240-Volt and is suitable for use in 100 Amp load centers. This ANSI-certified and CSA and UL-listed converter is compatible for use in both Murray and Siemens' Ultimate Load Centers. Allows for a means of disconnect in a single switch for all circuits in your Siemens Load Center.

  • Use to convert a main lug load center to a main breaker load center
  • Bolt on main breaker designed for use in ultimate load centers
  • Interrupting rating of 22KA 120/240V AC
  • ANSI certified and CSA and UL listed

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email
Eaton BR 1-30 Amp 2 Pole and 1-50 Amp 2 Pole BQC (Common Trip) Quad Circuit Breaker
Eaton BR 1-30 Amp 2 Pole and 1-50 Amp 2 Pole BQC (Common Trip) Quad Circuit Breaker
Item # 457054
UL Underwriters Laboratories (USA and Canada)

Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.

  • Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
  • Amperage - (1) 2-pole 30 Amp and (1) 2-pole 50 Amp
  • Number of poles - 4
  • Trip type - common
  • For use in type BR load centers
  • Interrupt rating - 10 kAIC
  • Voltage rating is 120/240-Volt
  • Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
  • Carry listing for HACR applications
  • Breaker has a rejection tab feature

Log in to see your price and availability.

Units: Each
Qty:

Add to Favorites List Add to Customized Product Offering Remove From Customized Product Offering Add To Bin Labels Added to Bin Labels. Click icon to print Bin Labels. Add To Custom Catalog Added To Custom Catalog. Click icon to print Custom Catalog. Email