Fuses & Accessories
Bussmann 3 Amp Fast Acting Blade Fuse. Bussmann Atc Blade-Type Fuse. 32 Volt. 3 Amp. Fast Acting. For HVAC Control Boards, Automotive And Small Appliance Circuits. Package Of 5. Mfg #BP/ATC-3-RP. Mfg #BP/ATC-3-RP
- Bussmann Atc Blade-Type Fuse
- 32 Volt
- 3 Amp
- Fast Acting
The Bussmann series BP-FRN-R-20 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 8 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 20 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Bussmann 5 Amp Fast Acting Blade Fuse. Bussmann Atc Blade-Type Fuse. 32 Volt. 5 Amp. Fast Acting. For HVAC Control Boards, Automotive And Small Appliance Circuits. Pkg Of 5. Mfg #BP/ATC-5-RP. Mfg #BP/ATC-5-RP
- Bussmann Atc Blade-Type Fuse
- 32 Volt
- 5 Amp
- Fast Acting
The Bussmann series BP-FRN-R-30 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 8 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 30 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
- Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA while delivering excellent short-circuit protection
The Bussmann series BP-FRN-R-25 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 25 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream FUSETRON fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
This is a 30 Amp to 60 Amp Class R Fuse reducer. This reducers allows for fitting a 30 Amp fuse in a 60 Amp block or disconnect switch. Fuse reducers install on fuse ferrules or blades.
- Reducers fit into most panels and switches, including dead-front type
- Strong contact is maintained both mechanically and electrically
- RoHS compliant
- 250-Volt
5 Amp fast acting blade type color coded fuse. Easy identification with violet plastic housing. Features an enclosed element offering protection against shocks and sparks, plus corrosion resistance for longer service life.
- Color code for every Amp rating
- Industry standard, used in most domestic and imported cars
- ATC blade fuses meet OEM and SAE standards
- Features an enclosed element - offering protection against shocks and sparks, plus corrosion resistance for longer service life
The Bussmann series BP-FRN-R-15 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 8 seconds (minimum) at 500% of rated current. For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 15 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream FUSETRON fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series TL-30PK4 is a pack of 4 time-delay, Edison base plug fuses. The medium duty TL fuses are ideal for residential motor circuits in kitchens, workshops, garages and utility rooms.Plug fuses thread into receptacles. Two types of threaded fuses are available: Edison base (brass) and rejection base (porcelain). The two are not interchangeable. TL and SL medium-duty fuses are regular duty fuses. T and S are heavy duty fuses for more demanding applications with high inrush currents. Plug fuses provide a compact and economical method to prevent electric motor damage, reduce downtime and lower maintenance costs by opening when an overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
- Features close sizing to motor load for additional protection
- Ceramic rejection base
- Time delay
- Rejection feature to help prevent over fusing (when used alone or with Fustat adapters to retrofit Edison-base holders)
- 125 V
- UL Listed
The Bussmann series BP-FRN-R-40 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 40 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series BP-NON-30 is a fast acting, non-current limiting cartridge fuse pack used in lighting circuits, main fuse panel protection and other circuits that don't contain large electric motors or inductive loads.Cartridge fuses are used to protect motors and branch circuits where higher amps or volt ratings are required. They are available in a wide variety of sizes, amp and volt ratings up to 600 Vac and 600 amps. Cartridge fuses are used extensively in commercial, industrial and agricultural applications as well as residential fuse panels, air conditioning, pumps, appliances and other equipment.As a fast-acting fuse, it is designed to respond quickly when an overcurrent event happens. Unlike time-delay fuses, fast-acting fuses do not have a built-in delay. Instead, they respond quickly to overcurrents to ensure that sensitive equipment is protected from potential damage caused by short circuits or other fault conditions. They are particularly useful to protect electronic devices and components that could be damaged by even short durations of overcurrent.
- For use in light-duty, general-purpose circuit applications
- Fast-acting, Class K5
- 1-time fuse, non-current limiting
- Available in 250 Vac and 600 Vac
- CSA and UL Listed
The Bussmann series BP-NON-20 is a fast acting, non-current limiting cartridge fuse pack used in lighting circuits, main fuse panel protection and other circuits that don't contain large electric motors or inductive loads.Cartridge fuses are used to protect motors and branch circuits where higher amps or volt ratings are required. They are available in a wide variety of sizes, amp and volt ratings up to 600 Vac and 600 amps. Cartridge fuses are used extensively in commercial, industrial and agricultural applications as well as residential fuse panels, air conditioning, pumps, appliances and other equipment.As a fast-acting fuse, it is designed to respond quickly when an overcurrent event happens. Unlike time-delay fuses, fast-acting fuses do not have a built-in delay. Instead, they respond quickly to overcurrents to ensure that sensitive equipment is protected from potential damage caused by short circuits or other fault conditions. They are particularly useful to protect electronic devices and components that could be damaged by even short durations of overcurrent.
- For use in light-duty, general-purpose circuit applications
- Fast-acting, Class K5
- 1-time fuse, non-current limiting
- Available in 250 Vac and 600 Vac
- CSA and UL Listed
The Bussmann series BP-FRN-R-35 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 35 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream FUSETRON fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series BP-FRN-R-50 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 50 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series TL-20PK4 is a pack of 4 time-delay, Edison base plug fuses. The medium duty TL fuses are ideal for residential motor circuits in kitchens, workshops, garages and utility rooms.Plug fuses thread into receptacles. Two types of threaded fuses are available: Edison base (brass) and rejection base (porcelain). The two are not interchangeable. TL and SL medium-duty fuses are regular duty fuses. T and S are heavy duty fuses for more demanding applications with high inrush currents. Plug fuses provide a compact and economical method to prevent electric motor damage, reduce downtime and lower maintenance costs by opening when an overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
- Features close sizing to motor load for additional protection
- Ceramic rejection base
- Time delay
- Tamper proof
- Rejection feature to help prevent over fusing (when used alone or with Fustat adapters to retrofit Edison-base holders)
- 125-Volt
- UL Listed
The Bussmann series BP-NON-40 is a fast acting, non-current limiting cartridge fuse pack used in lighting circuits, main fuse panel protection and other circuits that don't contain large electric motors or inductive loads.Cartridge fuses are used to protect motors and branch circuits where higher amps or volt ratings are required. They are available in a wide variety of sizes, amp and volt ratings up to 600 Vac and 600 amps. Cartridge fuses are used extensively in commercial, industrial and agricultural applications as well as residential fuse panels, air conditioning, pumps, appliances and other equipment.As a fast-acting fuse, it is designed to respond quickly when an overcurrent event happens. Unlike time-delay fuses, fast-acting fuses do not have a built-in delay. Instead, they respond quickly to overcurrents to ensure that sensitive equipment is protected from potential damage caused by short circuits or other fault conditions. They are particularly useful to protect electronic devices and components that could be damaged by even short durations of overcurrent.
- For use in light-duty, general-purpose circuit applications
- Operating maximum of 40 Amps and 250 Volts
- Fast-acting, Class K5
- 1-time fuse, non-current limiting
- UL- and CSA Listed
- Includes 2 fuses
The Bussmann series SL-30PK4 is a pack of 4 time-delay, rejection base plug fuses. The SL plug fuses are ideal for residential motor circuits in kitchens, workshops, garages and utility rooms.Plug fuses thread into receptacles. Two types of threaded fuses are available: Edison base (brass) and rejection base (porcelain). The two are not interchangeable. TL and SL medium-duty fuses are regular duty fuses. T and S are heavy duty fuses for more demanding applications with high inrush currents. Plug fuses provide a compact and economical method to prevent electric motor damage, reduce downtime and lower maintenance costs by opening when an overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
- Ideal for use with small motor and inductive load circuits
- Ceramic rejection base
- Time delay
- Tamper resistant
- Rejection feature to help prevent over fusing (when used alone or with Fustat adapters to retrofit Edison-base holders)
- 125-Volt
- UL Listed
The Bussmann series BP-FRN-R-60 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 60 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series TL-15PK4 is a pack of 4 time-delay, Edison base plug fuses. The medium duty TL fuses are ideal for residential motor circuits in kitchens, workshops, garages and utility rooms.Plug fuses thread into receptacles. Two types of threaded fuses are available: Edison base (brass) and rejection base (porcelain). The two are not interchangeable. TL and SL medium-duty fuses are regular duty fuses. T and S are heavy duty fuses for more demanding applications with high inrush currents. Plug fuses provide a compact and economical method to prevent electric motor damage, reduce downtime and lower maintenance costs by opening when an overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
- Features close sizing to motor load for additional protection
- Ceramic rejection base
- Time-delay
- Tamper proof
- Rejection feature to help prevent over fusing (when used alone or with Fustat adapters to retrofit Edison-base holders)
- 125-Volt
- UL Listed
The Bussmann series SL-20PK4 is a pack of 4 time-delay, rejection base plug fuses. The SL plug fuses are ideal for residential motor circuits in kitchens, workshops, garages and utility rooms.Plug fuses thread into receptacles. Two types of threaded fuses are available: Edison base (brass) and rejection base (porcelain). The two are not interchangeable. TL and SL medium-duty fuses are regular duty fuses. T and S are heavy duty fuses for more demanding applications with high inrush currents. Plug fuses provide a compact and economical method to prevent electric motor damage, reduce downtime and lower maintenance costs by opening when an overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
- Ideal for use with small motor and inductive load circuits
- Ceramic rejection base
- Time delay
- Tamper resistant
- Rejection feature to help prevent over fusing (when used alone or with Fustat adapters to retrofit Edison-base holders)
- 12-Volt
- UL Listed
The Cooper Bussmann 100 Amp 1-Time Brass Fuse Cartridge is a single-use, non-current limited cartridge fuse intended for general purposes. This is a Class H fuse with a time delay. The fuse is used for light-duty circuit locations.
- General purpose, single use, non-current limiting cartridge fuse
- Class H fuse for light-duty circuits
- Time delay feature
- 100 Amp
- 250-Volt
- UL- and CSA listed
The Bussmann series BP-SA-15 adapters convert Edison base receptacles to accept S- and SL-type rejection base fuses. SA adapters limit the fuse amp rating that can be installed to protect circuits from being overfused and are available in a variety of sizes to deliver the desired fuse rejection. Fuses not included.
- Adapts Edison-style base receptacles to accept S- and SL-type rejection fuses
- For use with S-7 to S-15 fuses
- UL and CSA safety listings
- 15 Amp, 125-Volt capacity
The Bussmann series SL-15PK4 is a pack of 4 time-delay, rejection base plug fuses. The SL plug fuses are ideal for residential motor circuits in kitchens, workshops, garages and utility rooms.Plug fuses thread into receptacles. Two types of threaded fuses are available: Edison base (brass) and rejection base (porcelain). The two are not interchangeable. TL and SL medium-duty fuses are regular duty fuses. T and S are heavy duty fuses for more demanding applications with high inrush currents. Plug fuses provide a compact and economical method to prevent electric motor damage, reduce downtime and lower maintenance costs by opening when an overload is present. When used for residential branch circuit protection, fuses are typically located in the main fuse panel.
- Ideal for use with small motor and inductive load circuits
- Ceramic rejection base
- Time delay
- Tamper proof
- Rejection feature to help prevent over fusing (when used alone or with Fustat adapters to retrofit Edison-base holders)
- 125-Volt
- UL Listed
The RK5 fuse provides motor overload, ground fault and short-circuit protection. Helps protect motors against burnout from single phasing on three phase systems. Simplifies and improves blackout prevention (selective coordination). Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection. The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds.
- 15 Amp
- 250-Volt
- UL Listed
- 1-pack