Searched for "40101700"
The First Co. HX fur down air fan coil with hot water heat. Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 2 ton fan coil piston
- 6kW electric heat
- 208/240v
- 24v controls
- Equipment should be sized, selected and installed by a qualified professional to ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty; see installation guide for more details
- Professional installation recommended
- HX Series
- Horizontal Fan Coils (Uncased)
- Heat Pump or DX - With Electric Heat
- (Heat pump w/Heat requires kit # 942-1)
- Features:
- Sloped and insulated drain pan
- Primary and secondary drains
- Easy service access
- 240/24V relay/transformer
- Copper tube coils
- Factory installed electric heat
- Metering Device: Piston
- For use with R22 or R410A refrigerant
- Dimensions (HxWxD): 10" x 43-1/4" x 21"
- 208/240-Volt power
- 24-Volt controls
- Factory installed 8kW electric heat
- Shipped with 2.5 ton piston
HX series of fan coil is for small room designs where a typical closet application can not be used. The small height allows the air handler to be mounted in a ceiling fur down space saving valuable floor space. Can be used for both strait cool and heat pump condensers. (check for compatibility) Made with high quality products and manufacturing.
- 3 ton size
- 5kW factory installed electric heat
- 240-Volt single connection power
- 24-Volt controls and compatible with most 24-Volt stats
The First Co. HX fur down air fan coil with hot water heat. Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 2-ton
- 10-KW electric heat
- 208/240-Volt
- Piston metering
HX series of fan coil is for small room designs where a typical closet application cannot be used. The small height allows the air handler to be mounted in a ceiling fur down space saving valuable floor space. Can be used for both strait cool and heat pump condensers. (check for compatibility) Made with high quality products and manufacturing.
- 2.5 ton size
- 208/240-Volt electrical
- 24-Volt controls and compatible with most 24-Volt stats
- Compatible with most 24-Volt stats
The First Co. HX fur down air fan coil with hot water heat. Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 208/240-Volt power
- 24-Volt controls
- Factory installed R410 TXV (non-bleed type)
- Insulated and coated galvanized steel drain pan is sloped for proper drainage
The First Co. HX fur down air fan coil with hot water heat. Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 208/240-Volt power
- 24-Volt controls
- Factory installed piston type metering device
- Factory installed 5kW electric heat
The First Co. HX fur down air fan coil with hot water heat. Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 208/240-Volt power
- 24-Volt controls
- Factory installed piston type metering device
- Insulated and coated galvanized steel drain pan is sloped for proper drainage
- 10kW factory installed
This is a genuine GOODMAN replacement part. It is designed for use in HVAC applications. See installation guide for more details. Professional installation recommended.
- Built with quality in mind
- Replacement part
- Slant coil
- Optimum performance
This is a genuine GOODMAN replacement part. It is designed for use in HVAC applications. See installation guide for more details. Professional installation recommended.
- Built with quality in mind
- Replacement part
- Slant coil
- Optimum performance
HBC horizontal recessed fan coil unit. Chilled water and hot water. 2-pipe with 3-row coil. 600 cfm left handed model.
- low horizontal unit
- 400 cfm
- 2 pipe 3 row
- right hand piping connections
The First Co. HX fur down air fan coil with hot water heat. Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 1.5 ton
- 208/240v
- 24v controls
- 6kW with piston
HBC horizontal recessed fan coil unit. Chilled water and hot water. 2-pipe with 3-row coil. 600 cfm left handed model.
- PSC motor
- 120v
- 2 Pipe 3 row coil
- Right hand piping connections
HBC horizontal recessed fan coil unit. Chilled water and hot water. 2-pipe with 3-row coil. 600 cfm left handed model.
- 600 CFM unit
- 2 pipe 3 row coil
- 120V
- left hand
HX series of fan coil is for small room designs where a typical closet application can not be used. The small height allows the air handler to be mounted in a ceiling fur down space saving valuable floor space. Can be used for both strait cool and heat pump condensers. (check for compatibility) Made with high quality products and manufacturing.
- 3 ton
- 208/240-Volt electrical
- 24-Volt controls
- compatable with most 24-Volt stats
The First Co. HX fur down air fan coil with hot water heat. Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 208/240-Volt power
- 24-Volt controls
- Factory installed R410 TXV (non-bleed type) factory installed R410 TXV
- Insulated and coated galvanized steel drain pan is sloped for proper drainage
HBC horizontal recessed fan coil unit. Chilled water and hot water. 2-pipe with 3-row coil. 600 cfm left handed model.
- 400 CFM
- 2 pipe 3 row coil
- 120v
- Left hand piping
HBC horizontal recessed fan coil unit. Chilled water and hot water. 2 pipe with 3 row coil. 800 cfm left handed model.
- 800 CFM
- 2 pipe 3 row
- 120V
- Left hand piping
Equipment should be sized, selected and installed by a qualified professional. To ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details.
- 208/240-Volt power
- 24-Volt controls
- Factory installed 8kW electric heat
- With 2 ton piston