Ignition Boards & Modules
Universal Integrated Furnace Control offers universal compatibility and diagnostics. It replaces a large number of furnace control models in single-stage warm air furnaces. Uses 120-Volt AC hot surface igniter. Includes instructions and special wire harnesses for easy replacement.
- Cross reference and wire harnesses provided for simple replacement over 195 existing furnace controls
- Main burner ignition using a 120-Volt hot surface igniter
- Flame rectification circuit to monitor flame presence
- Monitoring of system pressure switch, high temperature limit and rollout functions
Universal intermittent pilot ignition module replaces multiple field installed intermittent pilot modules supplied by Honeywell, Robertshaw, Johnson and UTEC (HSC). Uses existing intermittent pilot burner. Includes cross reference, instructions and accessories for easy replacement.
- Replaces over 400-white-rogers, robertshaw and honeywell intermittent pilot ignition modules
- Provides ignition sequencing, flame monitoring and safety shutoff for intermittent pilot warm air furnaces and heating appliances
- Provides 100% pilot gas shutoff if pilot fails to light; after 6-minute delay, trial for ignition is repeated, ignition trial/delay sequence is repeated until the appliance lights or call for heat is removed
- For use with natural or LP gas
Goodman OEM Control Board
- 2 Stage.
- Genuine OEM Gooman replacement board
- Replaces: PCBBF106S, PCBBF106, PCBBF107, L40-537
- 2-stage
- Ignition control board
Goodman Direct Replacement Integrated Furnace Control Single Stage Hot Surface Ignition for 120V Ignitors. Replaces Goodman 0130F00005, 0130F00005S, B1809926, B1809926S, PCBBF110, PCBBF110S, PCBBF112, PCBBF112S, PCBBF123, PCBBF123S, White-Rodgers 50T55-289, 50A55-289. Diagnostic LED indicators streamline installation.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Direct Replacement 2-in-1 Air Handler control for Carrier Single Stage Air Handler with PSC Blowers. Replaces Carrier HK61EA002 and HK61EA006. Direct Replacement Makes Install Quick and Easy.
- Fast drop-in OEM mounting and wiring
- Factory wiring for inline connector or spade terminals
- Dipswitch selectable blower off delay
- Replaces carrier HK61EA002 and HK61EA006
The Robertshaw 780 Series Pilot Controls feature flame rectification with solid-state logic and flame sensing to provide automatic sequencing that will ensure proper operation of an intermittent pilot ignition device. When the thermostat calls for heat, the 780 series control simultaneously initiates ignition sparking and opens the pilot valve portion of the gas valve. Pilot flame recognition stops ignition sparking and opens the main valve portion of the gas valve. Pilot burner flame is continuously monitored at a synchronous frequency for the duration of the heating cycle. Should the pilot flame fail during the heating cycle, the control will shut off the main valve until the pilot flame is established.
- Reduces truck stock inventory, saving space and money
- Easy-to-install with complete in-depth installation instructions
- Pilot and main valves draw 1 Amp at 0.5 power factor
- Combined load at 1.5 Amps at 0.4 power factor
- 95% relative humidity noncondensing at 104 degree F
York Direct Replacement Integrated Furnace Control Single Stage Hot Surface Ignition. For 120V Ignitors. Replaces York , 265901, 265902, 539617, S1-03100662000, S1-03101250000, S1-03101266000, S1-03101267000, S1-03101267001, S1-03101284000, S1-03101933000,S1-03101972000, S1-03101973000, S1-03109167000, S1-33102956000, S1-33103010000, White-Rodgers 50A56-242, 50A56-243.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Limit, Reset Manual. Mfg #20162904S
- 150 Open
- 110 Close
- Brown
- Green
Designed For Molded Shower Stalls
- The Drain Is Installed On The Shower Unit Before It Is Placed
- Stainless Steel Snap-In Strainer
- Compression Gasket
- Reference #140Nc
- Fits 2" Schedule 40 Plastic Or 2" Cast Iron Pipe
- High-quality stainless steel strainer for enhanced durability
- Compatible with 2 in. Schedule 40 plastic or cast iron pipes
- Can be easily installed on the shower unit for quick setup
- Ideal for use in molded shower stalls
This is a genuine ICP OEM part. Installation by a licensed professional is recommended. This part is suitable for HVAC applications.
- Genuine ICP OEM part
- Suitable for use in HVAC applications
- Professional installation recommended
- More ICP OEM parts available through special orders
MFG Part# 415-46557-00
- Genuine OEM product
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)
Genuine Rheem OEM part. Installation by a licensed professional is recommended. This part is suitable for HVAC applications.
- Genuine Rheem OEM part
- Suitable for use in HVAC applications
- Professional installation recommended
- More Rheem OEM parts available through special orders
Control Board
- 2 Stage
- 24v
- For Gas Furnace Applications (pilots, flame sensors, etc.)
Control Board
- 2 Heat
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)
Goodman Direct Replacement Integrated Furnace Control Hot Surface Ignition. 2-Stage for 120-Volt Ignitors and Variable Speed Motors. Works with HVAC Legacy 24-Volt or 4 Wire Communicating Systems. Replaces PCBKF101(S), 102(S), 103(S), 104(S).
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- 2-stages
- 120 Vac hot surface ignition
- For variable speed motors
MFG Part# HK42FZ086
- Genuine OEM product
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)
Lennox Direct Replacement Integrated Furnace Control Hot Surface Ignition for 80V Ignitors. Replaces Lennox 100925-01, 100925-02, 100925-03, 17W92, 17W9201, 23W51, 23W5101, 30W25, 30W2501, 69M08, 69M0801, 69M15, 69M1501, White-Rodgers 50A66-122, 50A66-123. Features diagnostic LED indicators streamline installation.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Control Board
- Genuine OEM product
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)
Control Board
- 3amp Fuse
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)
Control Board
- Terminal Board Kit
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)
Trane Direct Replacement Non-Integrated Ignition Module Single Stage Hot Surface Ignition for 120-Volt Ignitors Used in Commercial Rooftop and Package Unit. Also Replaces Trane Kit 17852. Applications for Hot Surface Ignition Systems.
- Replaces standard and adaptor board style controls
- For hot surface ignition systems
- Non-integrated model provides burner supervision
- 1-stage
- 120 Vac hot surface ignition
Control Board
- Fuse: 3.15A, 250V
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)
MFG Part# S1-MCB-1011HP
- Genuine OEM product
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)
Control Board
- Blower Control
- Multiple applications (such as drain pans or anything driven by a size or dimension)
- For Gas Furnace Applications (pilots, flame sensors, etc.)