Searched for "40101700"
The Emerson 90-244 2 pole is a definite purpose contactor for air conditioning and heating equipment. This contactor features low VA coil for cooler operation. The universal mounting bracket fits existing mounting holes. 24 VAC. 30 Amp.
- Low voltage coil for increased life
- Quiet operation
- Universal mounting bracket fits most applications
- Double break contacts ensure positive make and break
- 24-Volt AC
- Resistance DC OHMS 11
- Current MA 150
- Nominal VA 6
- Maximum inrush VA 32
Supply your technicians with only the best components to get the job done the right way the first time. These contactors are manufactured from the highest quality materials. Backed by designs that are tried and tested to perform.
- Accordance with U.L. bulletin no. 508 Industrial control equipment, contactors meet specifications for devices up to 600 VAC
- Coils have class B insulation
- Includes lug, spade terminals, and covers
- Single pole include shunt
The Emerson two pole double throw semi-enclosed relay for use in vending machines, appliances, heating and air conditioning applications, and general-purpose switching. This is a switching relay is a 2 Pole relay with 24 VAC coil. This Type 91 relay features DPDT switching and two sets of power rated contacts.
- Easy install
- -40 degree F to 130 degree F temperature range
- Coil voltage 24 Hz
- Coil DC resistance 17.5
- Coil MA 334
- Coil nominal VA 9.5
- Coil inrush VA 22
The Emerson 24A34 series electric heat sequencer is a direct replAcement for most fan and heat sequencing functions. This electric heat sequencer features 2 switches and multi-poise mounting. 24 volt input control.
- Terminal markings are equivalent to other types
- 24-Volt input control
- Multi-poise mounting
- Double quick-connect terminals for combination loads
- 1 switch
- On timings 30 - 90 seconds
- Off timings 1 - 30 seconds
The Emerson 24A34-3 Electric Heat Sequencer is a direct replacement for most fan/heat sequencing functions. This sequencer features 2 switches and multi-poise mounting. This sequencer features 2 switches and multi-poise mounting.
- Direct replacement for most fan / heat sequencing functions
- 2 switches
- On timings: 1-20 sec
- Off timings: 40-110 sec
- 24-Volt input control
24-Volt Heat Sequencer, fan and electric, 2 Switches. On Timings, 30-90 seconds. Off timings 1-30 seconds. Replaces Honeywell, MARS, TOD, GEMLINE, Klixon (Texas Instruments). UL component recognized.
- Direct replacement for most fan / heat sequencing functions
- 2 switches
- On timings: 30-90 seconds
- Off timings: 1-30 seconds
- 24-Volt input control
- Multi-poise mounting
- Any contacts (except M1 and M2) can be used as auxiliary contacts
- Double quick-connect terminals for combination loads
This is a genuine Goodman replacement part. Equipment should be sized, selected and installed by a qualified professional to ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details. Professional installation recommended.
- SEQUENCER B12565-52
- HVAC application
- Dimensions: 4 in. x 23.75 in. x 30.75 in.
- Quality build
A very durable contacted that is capable of carrying more amperage. Manufactured with quality material that ensures a good direct contact so the device can function properly. This contactor works with 99% of residential AC units.
- 40 inductive Amps
- 50 resistive Amps
- 240/200/160 locked rotor Amps
- Auxiliary switches sold separately
The Emerson 90-341 two pole double throw semi-enclosed relay is for use in vending machines, appliances, heating and air conditioning applications, and general-purpose switching. This switching relay is a 2 Pole relay with 115/120 VAC coil. This Type 91 relay features DPDT switching and two sets of power rated contacts.
- Easy install
- -40 degree F to 130 degree F temperature range
- Coil voltage 115/120 Hz
- Coil DC resistance 420
- Coil MA - 66
- Coil nominal VA 9.5
- Coil Inrush VA 22
The Emerson 90-118E fan control center combination transformer and relay combination, SPNO/SPNC, 120 V primary. This fan control center can be installed on on a 4 in. x in. junction box. The pre-wired line voltage connections and color-coded and pre-striped leads provide easy installation. Energy limiting class II transformer design and low voltage connections on terminal board.
- 24 VAC secondary
- Line voltage connections pre-wired
- Color coded pre-stripped leads for easy install
- Low voltage connections on terminal board
- Easy installation on a 4 in. x 4 in. junction box
This is a genuine GOODMAN replacement part. Equipment should be sized, selected and installed by a qualified professional to ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details. Professional installation recommended.
- HVAC application
- Dimensions: 11.25 in. x 8 in. x 0.5 in.
- For use with GOODMAN and Amana equipment
- PCB, defrost control
The Emerson 90-370 heavy-duty general-purpose relay for heating and cooling applications and general switching. This is a totally enclosed relay, which operates in any position. This relay provides general-purpose switching for heating and cooling applications.
- SPDT
- 24V VAC coil, 50/60hz
- Resistive DC OHMS 77
- Coil nominal current MA 125
- Coil nominal VA sealed 3
- Inrush VA 4
The Emerson 90-290Q through 90-295Q relays for switching single or two speed fan motors, solenoids, relays, resistive loads, and general-purpose switching. This fan relay features a compact, totally enclosed design, which provides quiet, reliable and economical operation. This relay has SPNO switching. 24 VAC.
- Compact and fully enclosed design
- Quiet operation
- SPDT
- 208/240 VAC coil
- Resistance DC OHMS 90
- Coil nominal current MA 125
- Coil nominal VA sealed 3
- Inrush VA 4
CONT2P040024VS GOODMAN Replacement Air Handler Contactor complies with warranty parts requirements for GOODMAN HVAC Equipment. GOODMAN Replacement parts are direct OEM replacements that requires no modifications for ease of replacement. Please review your GOODMAN Equipment Product Specifications to ensure that CONT2P040024VS replacement Ceiling Mount Air Handler Contactor is the applicable replacement part for your system.
- For use in GOODMAN and Amana furnaces
- Genuine OEM replacement part
- Be sure to reference furnace model and version for appropriate replacement part
- OEM part requires no modification for easy installation
This is a genuine Goodman replacement part. Equipment should be sized, selected and installed by a qualified professional to ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details. Professional installation recommended.
- Sequencer B12565-51
- HVAC application
- Dimensions: 0.99 in. x 0.99 in. x 0.99 in.
- Quality build
24-Volt Heat Sequencer. Fan and electric, 1 switch. On timings, 1-20 Seconds. Off timings 40-110 seconds. Replaces Honeywell, MARS, TOD, GEMLINE, Klixon (Texas Instruments). 24-Volt input control Multi-pose mounting Any contacts (except M1 and M) can be used as auxiliary contacts Double quick-connect terminals for combination loads Ambient Temperature Rating: -50 to +165 degree F UL component recognized.
- Direct replacement for most fan / heat sequencing functions
- 1 switch
- On timings: 30-90 seconds
- Off timings: 1-30 seconds
- 24-Volt input control
- Multi-poise mounting
- Any contacts (except M1 and M2) can be used as auxiliary contacts
- Double quick-connect terminals for combination loads
24-Volt Heat Sequencer, fan and electric, 3 Switches. On timings, 1-110 seconds. Off timings 1-110 seconds. Replaces Honeywell, MARS, TOD, GEMLINE, Klixon (Texas Instruments). 24-Volt input control and multi-pose mounting. UL component recognized.
- Direct replacement for most fan/heat sequencing functions
- 3 switches
- On timings: 1-110 seconds
- Off timings: 1-110 seconds
- 24-Volt input control
- Multi-poise mounting
- Any contacts (except M1 and M2) can be used as auxiliary contacts
- Double quick-connect terminals for combination loads