Hvac Controls
The Robertshaw 1980 Series Snap-Fit Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures. Various lengths are available.
- Easy burner installation with attached threaded nut
- Stainless steel outer jacket for long life and resistance to heat blistering
- Combination of copper and nickel alloys for good electrical conductivity
- Mica washer to insulate from shorting conditions
- Tinnerman clip included
- Various lengths available for multiple applications
Rectorseal Safe-T-Switch SS2 New
- Condensate Overflow Switch
- Adjustable ratcheting float level
- Magnetic reed switch
- POP Blister packaged
- Mfg #97087
- Condensate Overflow Switch
- Adjustable ratcheting float level
- Magnetic reed switch
- POP Blister packaged
The Emerson two pole double throw semi-enclosed relay for use in vending machines, appliances, heating and air conditioning applications, and general-purpose switching. This is a switching relay is a 2 Pole relay with 24 VAC coil. This Type 91 relay features DPDT switching and two sets of power rated contacts.
- Easy install
- -40 degree F to 130 degree F temperature range
- Coil voltage 24 Hz
- Coil DC resistance 17.5
- Coil MA 334
- Coil nominal VA 9.5
- Coil inrush VA 22
The Robertshaw 1980 Series Snap-Fit Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures. Various lengths are available.
- Easy burner installation with attached threaded nut
- Stainless steel outer jacket for long life and resistance to heat blistering
- Combination of copper and nickel alloys for good electrical conductivity
- Mica washer to insulate from shorting conditions
- Tinnerman clip included
- Various lengths available for multiple applications
The Emerson 90-244 2 pole is a definite purpose contactor for air conditioning and heating equipment. This contactor features low VA coil for cooler operation. The universal mounting bracket fits existing mounting holes. 24 VAC. 30 Amp.
- Low voltage coil for increased life
- Quiet operation
- Universal mounting bracket fits most applications
- Double break contacts ensure positive make and break
- 24-Volt AC
- Resistance DC OHMS 11
- Current MA 150
- Nominal VA 6
- Maximum inrush VA 32
Supply your technicians with only the best components to get the job done the right way the first time. These contactors are manufactured from the highest quality materials. Backed by designs that are tried and tested to perform.
- Accordance with U.L. bulletin no. 508 Industrial control equipment, contactors meet specifications for devices up to 600 VAC
- Coils have class B insulation
- Includes lug, spade terminals, and covers
- Single pole include shunt
Goodman Oem Control Board. Style: Ecm time delay
Goodman flame sensor
- Genuine OEM replacement Part
- For use with Goodman & Amana equipment
- OEM part requires no modification for easy installation
- Be sure to reference furnace model and version for appropriate replacement part
Rectorseal Safe-T-Switch SS1 New - Primary drain line shut-off switch, detects clogged A/C condensate drains
- Condensate Overflow Switch
- Adjustable ratcheting float level
- Magnetic reed switch
- Code compliant inline cleanout
- Cleanout Tool
- Mfg #97085
- Condensate Overflow Switch
- Adjustable ratcheting float level
- Magnetic reed switch
- Code compliant inline cleanout
The 24A34-3 Electric Heat Sequencer is a direct replacement for most fan/heat sequencing functions. This sequencer features 2 switches and multi-poise mounting. This sequencer features 2 switches and multi-poise mounting.
- Direct replacement for most fan / heat sequencing functions
- 2 switches
- On timings: 1-20 sec
- Off timings: 40-110 sec
- 24-Volt input control
Enclosed fan relay type 184, 24-Volt coil, SPNO-SPNC. Used for switching Solenoids, fan motors and general purpose switching. UL file number E12139 CSA file number LR13360.
- Coil-voltage 24-Volt
- Normally opened / closed type
- 1/4 in. spade connections 5 pin
- Coils frequency 50 Hz/60 Hz
The Robertshaw 1980 Series Snap-Fit Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures. Various lengths are available.
- Easy burner installation with attached threaded nut
- Stainless steel outer jacket for long life and resistance to heat blistering
- Combination of copper and nickel alloys for good electrical conductivity
- Mica washer to insulate from shorting conditions
- Tinnerman clip included
- Various lengths available for multiple applications
The Robertshaw Carbide Series Hot Surface Ignitors deliver dependable ignition in heating systems. The applications include: furnaces, boilers, rooftop heaters, infrared burners, unit heaters, and water heaters. They can also be used in many other types of HVAC equipment.
- Made from high-purity recrystallized silicon carbide (CrystarTM) which combines physical and thermal strength with stable electrical properties
- Designed to reach ignition temperature(s) within 17 seconds
- Have 18-Gauge nickel chrome lead wires embedded and metalized in place for maximum holding strength and electrical conductivity
- Manufactured with lead wires enclosed in a special high-temperature fiberglass insulation providing electrical protection
- Operate at 120-Volt AC. some modules are rated for 208-Volt/240-Volt input, however, the voltage to the ignitor is stepped down to 120-Volt AC
Rectorseal Safe-T-Switch SS3 New
- Condensate Overflow Switch
- Adjustable ratcheting float level
- Magnetic reed switch
- POP Blister packaged
- Fits 1" to 2" drain pan height
- Mfg #97089
- Condensate Overflow Switch
- Adjustable ratcheting float level
- Magnetic reed switch
- POP Blister packaged
The 24A34 series electric heat sequencer is a direct replAcement for most fan and heat sequencing functions. This electric heat sequencer features 2 switches and multi-poise mounting. 24 volt input control.
- Terminal markings are equivalent to other types
- 24-Volt input control
- Multi-poise mounting
- Double quick-connect terminals for combination loads
- 1 switch
- On timings 30 - 90 seconds
- Off timings 1 - 30 seconds
The Robertshaw 1950 and 1951 Series Thermopiles lead the industry for gas appliance applications. Their primary function is to ensure a standing pilot light is operative so that on a call for heat, the main burner gas will be properly ignited. Thermopiles are placed in gas applications to detect the existence of a flame for safety purposes by shutting off the potential gas flow to a burner. A thermopile is the assembly of many thermocouples to increase the millivolt output. Robertshaw thermopiles have two types of connections: coaxial and two-wire spade connectors. The 1950 Series Thermopiles, also known as TP-75, are two-wire spade connectors. The 1951 Series Thermopiles, also known as CP-2 (250 to 750 millivolts), are coaxial connectors. The 1950 and 1951 Series Thermopiles (pilot generators) are designed for use on self-powered gas control systems. They can be used to replace similar competitive devices. It includes PG9 Pilot Adaptor.
- Easy burner installation with attached threaded nut
- Stainless steel outer jacket for long life and resistance to heat blistering
- Combination of copper and nickel alloys for good electrical conductivity
- Mica washer to insulate from shorting conditions
- Tinnerman clip included
- Various lengths available for multiple applications
24-Volt Heat Sequencer, fan and electric, 2-Switches. On Timings, 30-90 seconds. Off timings 1-30 seconds. Replaces Honeywell, MARS, TOD, GEMLINE, Klixon (Texas Instruments). UL component recognized.
- Direct replacement for most fan / heat sequencing functions
- 2 switches
- On timings: 30-90 seconds
- Off timings: 1-30 seconds
- 24-Volt input control
- Multi-poise mounting
- Any contacts (except M1 and M2) can be used as auxiliary contacts
- Double quick-connect terminals for combination loads
- Time delay relay. 24 volt coil
- On: 1-25 seconds. Off: 65-115 seconds
- Replacement for Goodman B13707-38
- UL® and CSA® approved
- 24 volt control circuit
- Five second delay between all subsequent stages, unless they function together
- Used on gas and electric units
This is a genuine Goodman replacement part. Equipment should be sized, selected and installed by a qualified professional to ensure proper installation, safe operation, adherence to federal, state and local codes and for valid warranty. See installation guide for more details. Professional installation recommended.
- Sequencer B12565-51
- HVAC application
- Dimensions: 0.99 in. x 0.99 in. x 0.99 in.
- Quality build
The Robertshaw 1980 Series Snap-Fit Thermocouples offer easy installation into the majority of pilot burners. They are manufactured without complicated adaptors, but with extra insulation that the brass sheath provides under high ambient temperatures. Various lengths are available.
- Easy burner installation with attached threaded nut
- Stainless steel outer jacket for long life and resistance to heat blistering
- Combination of copper and nickel alloys for good electrical conductivity
- Mica washer to insulate from shorting conditions
- Tinnerman clip included
- Various lengths available for multiple applications
The White-Rodgers 50A55-843 universal silicon carbide integrated hot surfAce ignition replAcement control kit. This ignition module replAces most Trane, York, ICP, Amana and White-Rodgers models. This module offers easy installation with the mounting plate (included in the box).
- Flash code diagnostics for easy service
- Fused to protect low voltage system transformers
- Includes mounting template
- Adjustable blower delay
- Pre-purge 30-seconds
- Delay heat on 30/45
- Delay heat off 60/90//120/180
- Delay cool on 5
- Delay cool off 45/90
- Input voltage 25 VAC 50/60 Hz
A very durable contacted that is capable of carrying more amperage. Manufactured with quality material that ensures a good direct contact so the device can function properly. This contactor works with 99% of residential AC units.
- 40 inductive Amps
- 50 resistive Amps
- 240/200/160 locked rotor Amps
- Auxiliary switches sold separately
This is a genuine GOODMAN replacement part. This ignitor can be used in HVAC gas ignition controls. It is compatible with GOODMAN packaged units.
- Furnace hot surface ignitor
- Fits GOODMAN furnaces
- Manufactured with quality in mind
- Compatible with GOODMAN furnaces
24-Volt Heat Sequencer. Fan and electric, 1-switch. On timings, 1-20 Seconds. Off timings 40-110 seconds. Replaces Honeywell, MARS, TOD, GEMLINE, Klixon (Texas Instruments). 24-Volt input control Multi-pose mounting Any contacts (except M1 and M) can be used as auxiliary contacts Double quick-connect terminals for combination loads Ambient Temperature Rating: -50 to Plus165 ° F UL component recognized.
- Direct replacement for most fan / heat sequencing functions
- 1 switch
- On timings: 30-90 seconds
- Off timings: 1-30 seconds
- 24-Volt input control
- Multi-poise mounting
- Any contacts (except M1 and M2) can be used as auxiliary contacts
- Double quick-connect terminals for combination loads
