Hydronic Valves & Controls
The VR-801 Vacuum Relief Valve is designed to protect hot water supply systems and pressure vessels against negative pressure. Installed on the cold water supply line, the Cash Acme VR-801 closes tightly under pressure and opens at a 1 in. mercury vacuum. Atmosphere admitted to the system breaks the vacuum, preventing collapse of the storage tank.
- Brass body
- Silicone seat disc
- Prevents internal vacuum conditions
- Guards against siphonage
- Opens quickly in emergency situations
- Every valve is tested for performance prior to shipping
This 1/2 inch bronze combination fill valve and backflow preventer is for use in commercial and residential hydronic heating systems to provide make-up water to the boiler, and prevent backflow when supply pressure falls below system pressure. It consists of a bronze backflow preventer, model 9D and a bronze feed water pressure regulator, model 1156F, in one pre-assembled unit. The high capacity fill valve provides quick system filling and purging. It is designed for use in the boiler feed lines of hydronic heating systems and has 1/2 inch union NPT inlet x NPT threaded outlet connections. The maximum pressure is 100 psi (6.9 bar).
- Bronze body for durability
- Threaded connections
- Strainer screen
- Horizontal or vertical installation
- Maximum pressure is 100 psi
- One pre-assembled unit of fill valve and backflow preventer
Nibco ACR Copper Coupling
- 0.75" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #039923307125
- 0.75" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
Nibco ACR Copper Coupling
- 0.5" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #039923306944
- 0.5" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
Nibco ACR Copper Coupling
- 0.25" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #9000353
- 0.25" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
This 3/4 in. lead free temperature and pressure relief valve is designed to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 105,000 BTU per hour. This two in one relief valve provides a proven and cost effective means to protect against excessive temperature and pressure emergency conditions. It features a lead free copper alloy body with NPT male inlet and NPT female outlet connections, a unique thermostat with special thermo-bonded coating, and test lever. The temperature relief is 210 degree (99 degree C) and the pressure relief is set at 125 psi (8.6 BAR).
- Lead free copper body construction
- Unique thermostat with special thermo-bonded coating
- Protects against excessive temperature and pressure during emergency conditions
- Temperature relief is 210 degree F (99 degree C)
- Pressure relief set at 125 psi
- ASME rated, CSA listed
- 3/4 in. NPT male inlet and NPT female outlet connections
- Used to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 105,000 BTU/hr
- ANSI Z21.22 certified
- Automatic reseating
- This fitting includes a split ring and a stainless steel insert. It's also self-flaring, which means no flaring tool is needed.
*MUST BE INSTALLED BY TRAINED PERSONNEL IN ACCORDANCE WITH NFPA 58 & 54 STATE AND LOCAL CODES
- Self-flaring design ensures versatile use
- Metal-to-metal seal for durable and reliable operations
- Features 33% more sealing surface than contemporaries
- Made of high-grade brass for enhanced strength
This 1 in. lead free brass water pressure reducing valve is the standard model, designed to reduce incoming water pressure to protect plumbing systems and reduce water consumption for commercial, industrial and residential applications. The easy maintenance assembly consists of a replaceable seat module, NPT threaded female union inlet by NPT female outlet and a bypass feature to control thermal expansion pressure. The temperature range is 33 to 160 degree F (0.5 to 71 degree C). Suitable for up to 300 psi (20.7 BAR), the pressure range can be adjusted from 25 to 75 psi (172 to 517 kPa) with the standard setting at 50 psi (345 kPa).
- NPT threaded female union inlet by NPT female outlet
- Sealed spring cage with stainless steel cage screws
- Integral stainless steel strainer removable for cleaning
- Replaceable seat module
- Suitable for up to 300 psi
- Pressure range can be adjusted from 25 to 75 psi
- Temperature range is 33 to 160 degree F
- Designed to reduce incoming water pressure to protect plumbing systems
- Designed to reduce water consumption for commercial, industrial and residential applications
- Standard setting at 50 psi
This 3/4 by 3/4 in. lead free dual check valve prevents the reverse flow of polluted water from entering into the drinking water supply at the service entrance or at individual outlets. The valve consists of a lead free brass body construction, with two plastic replaceable check valves, and stainless steel springs. It is designed for non-health hazard residential water system containment, continuous pressure applications and is to be installed immediately downstream of the residential water meter, in a vertical or horizontal position. The minimum working pressure is 10 psi (69 kPa) and maximum working pressure is 175 psi (12 BAR).
- Lead free brass body for durability
- Can be installed vertically or horizontally
- Compact design
- Meets ANSI/ASSE Standard 1024
- 3/4 in. union female NPT inlet x female NPT outlet
- Designed for non-health hazard residential water system containment
Nibco ACR Copper 90degree Long Radius Elbow
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Mfg #9080400
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- with stop
Nibco Copper Coupling. Mfg #9020400
- 0.75" Inlet
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Without Stop
- 4 in 1 alternative replaces a ball valve and 2 tee fittings and 1 boiler drain
- Quickly connect entire system to cold water feed
- Easily install, isolate, drain and replace any expansion tank
- Pressure rated at 600 WOG
- 1/2" FIP x MIP x FIP x HOSE
This 1/8 in. automatic air vent valve is used in commercial and residential hydronic heating applications to provide automatic air venting for hot or cold water distribution systems. It consists of a brass body construction with male NPT connection, brass cover, air vent with silicone rubber seal, polyethylene float with valve plug, and automatic vent. It has a high temperature rating and is ideal for use with glycol systems or for use as an anti-vacuum device. It can also be installed to permit the separation and dispersal of air while fluid is circulating in the system. It can be disassembled for inspection and cleaning. The maximum pressure is 150 psi (10 BAR).
- Body and cover are brass construction
- Air vent with silicon rubber seal
- Float is high temperature resistant polyethylene
- Suitable for use with glycol systems
- Can be disassembled for inspection and cleaning
- Provides automatic air venting for hot or cold water distribution systems
- Purge air that may be in the water system
- Minimum working pressure is 1.45 psi
- Maximum working pressure is 150 psi
- Temperature range is 33 to 240 degree F
Watts 3/4 IN 374A Iron Boiler Pressure Relief Valve, 30 psi, Forged Brass Inlet Features A Flood Sensor With Sentryplus Alert Technology To Detect Excessive Water Discharges From The Relief Valve Requires purchase of activation kit to activate sensor Iron body with forged bronze inlet 550,000 BTU/hr rating Non-metallic disc-to-metal seating Set pressure 30 psi Mfg #F358553
- Features A Flood Sensor With Sentryplus Alert Technology To Detect Excessive Water Discharges From The Relief Valve
- Requires purchase of activation kit to activate sensor
- Iron body with forged bronze inlet
- 550,000 BTU/hr rating
This 3/4 in. lead free brass water pressure reducing valve is designed to reduce incoming water pressure to protect plumbing systems and reduce water consumption for commercial, industrial and residential applications. The easy maintenance assembly consists of a replaceable seat module, a solder union inlet by NPT female outlet and a bypass feature to control thermal expansion pressure. The temperature range is 33 to 160 degree F (0.5 to 71 degree C). Suitable for up to 300 psi (20.7 BAR), the pressure range can be adjusted from 25 to 75 psi (172 to 517 kPa) with the standard setting at 50 psi (345 kPa).
- Solder union inlet by NPT female outlet
- Sealed spring cage with stainless steel cage screws
- Integral stainless steel strainer removable for cleaning
- Replaceable seat module
- Suitable for up to 300 psi
- Pressure range can be adjusted from 25 to 75 psi
- Temperature range is 33 to 160 degree F
- Designed to reduce incoming water pressure to protect plumbing systems
- Designed to reduce water consumption for commercial, industrial and residential applications
- Standard setting at 50 psi
AM-1 series adjusts, maintains and limits the hot water temperature settings to provide comfort and protect equipment at home. Designed to prevent scalding water and legionella bacteria growth by storing water at 140 degree F and higher. Delivers safe and comfortable water temperatures out of the faucet at 120 degree F.
- Offers constant water temperature under changing operating conditions
- Temperature is limited at any point and if cold water supply is interrupted, flow reduction occurs in seconds
- Designed for easy maintenance and Teflon coating prevents mineral build-up and extends life
- Provides reliable performance at minimum flow of 05 GPM and proportional valve for simultaneous control of hot and cold
- Features dual purpose mixing or diverting values
- Lead free products have products numbers end in LF
- Available temperature gauge adapter in lead-free brass material with EPDM O-ring
- Maximum safe operating pressure (psi)150 psi
- Minimum flow rate (gpm) 0.5 GPM
- Includes check valves on hot and cold ports
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
Danfoss Aveo Sensors, Electronic, Sensor type. Easy To Use. Thermostatic Radiator Valve. Built in Tamper Proof. 015G4290. Mfg #015G4290
- Easy To Use
- Thermostatic Radiator Valve
- Built in Tamper Proof
- 015G4290
Pressure regulating valve for automatic control of boiler feed water and other pressure reducing applications. Especially constructed for expansion tank mounting. Included in many expansion kits.
- Fast fill feature
- Built in check valve
- Easy dial-set technology allows simple output pressure setting in psi
- Integrated NPT pressure gage port for testing
This 3/4 inch lead free temperature and pressure relief valve is designed to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 105,000 BTU/hr. This two-in-one relief valve provides a proven and cost effective means to protect against excessive temperature and pressure emergency conditions. It features a lead free copper alloy body with extended shank to accommodated up to 1 3/4 IN of insulation, NPT male inlet and NPT female outlet connections, a unique thermostat with special thermo-bonded coating, and test lever. The temperature relief is 210 degrees F (99 degrees C) and the pressure relief is set at 150 psi (10.3 bar).
- Lead free copper alloy body construction
- Extended shank for thick tank insulation up to 1 3/4 inches
- 3/4 IN male NPT inlet with pre-applied thread sealant
- ASME rated and CSA listed
- Pressure relief range is 75 to 150 psi
- ASME rated, CSA Listed
- Extension thermostat with thermo-bonded coating
- Used to provide automatic temperature and pressure protection to hot water supply tanks and hot water heaters up to 105,000 BTU/hr
- ANSI Z21.22 certified
- Includes test lever and stainless steel spring
Honeywell Home's 802360JA/U is a 24-Volt replacement motor for V8043/44 zone valve. It is the ideal choice for contractors because of its easy installation. When it comes to top quality, Honeywell Home's zone valves can be trusted.
- Valve includes motor mounting screw and lead connectors
- Used with V8043A, V8043E, and V8043F
- Frequency-50 Hz, 60 Hz
- 24-Volt electrical connections
- Electrical connections - 6 in. leads; 152 mm leads
This is a pressure reducing valve. It is a genuine Bell & Gossett valve. It includes a fast-fill feature.
- Bronze body
- Built-in check valve
- Replaceable strainer
- 1/2" NPT connections
- Factory setting 12 PSIG
- Adjustable range 10-25 PSIG
The Honeywell Home Aquastat Relay is designed for use with an HVAC heating system. This immersion-type controller provides high limit protection while switching control of the oil burner and the circulator. Compatible with Honeywell Home models.
- Designed for use with an HVAC heating system
- 120 240 degree F range with 8 degree F fixed differential, low volt/millivolt
- Select models include transformer and accessory terminals for adding a remote low limit controller
- Requires a 24 VAC thermostat with heat anticipator set at 0.2A