Searched for "40141616"
Nibco ACR Copper Coupling
- 0.5" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #039923306944
- 0.5" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
AM-1 series adjusts, maintains and limits the hot water temperature settings to provide comfort and protect equipment at home. Designed to prevent scalding water and legionella bacteria growth by storing water at 140 degree F and higher. Delivers safe and comfortable water temperatures out of the faucet at 120 degree F.
- Offers constant water temperature under changing operating conditions
- Temperature is limited at any point and if cold water supply is interrupted, flow reduction occurs in seconds
- Designed for easy maintenance and Teflon coating prevents mineral build-up and extends life
- Provides reliable performance at minimum flow of 05 GPM and proportional valve for simultaneous control of hot and cold
- Features dual purpose mixing or diverting values
- Lead free products have products numbers end in LF
- Available temperature gauge adapter in lead-free brass material with EPDM O-ring
- Maximum safe operating pressure (psi)150 psi
- Minimum flow rate (gpm) 0.5 GPM
- Includes check valves on hot and cold ports
Nibco ACR Copper 90degree Elbow. 0.88" Od. Dezincification Resistant. NFPA 99 Health Care Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas). Mfg #9055600
- 0.88" Od
- Dezincification Resistant
- NFPA 99 Health Care Facilities Gas And Vacuum Systems
- Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
Nibco ACR Copper Coupling
- 0.63" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #9001193
- 0.63" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
The Pro-Pal Ball Drain is a full port forged brass ball valve. It features a hi-flow hose drain, adjustable packing glands, and reversible handle. The exclusive adjustable flow path allows for draining from either side of the ball.
- Replaces 4 components; eliminates 3 leak paths; saves nearly 30 minutes in labor
- Eliminates assemblies needed to isolate and drain any portion of a piped system
- Avoids reduced port alternatives
- Certified to NSF/ANSI 61 & 372
- Reversible handle for added versatility
- Exclusive adjustable flow path allows for draining from either side of the ball
Watts 1 IN Lead Free Reduced Pressure Zone Backflow Preventer Assembly Features Flood Sensor With Sentryplus Alert Technology To Detect Excessive Water Discharges From The Relief Valve Alert features available with add-on sensor connection kit Lead free copper silicon alloy body NPT inlet and outlet connections Quarter turn full port resilient seated ball valve shutoffs Single access cover and modular check construction for the ease of maintenance Internal relief valve for reduced installation clearances Replaceable seats for an economical repair Test cocks are screwdriver slotted Mfg #88004112
- Features Flood Sensor With Sentryplus Alert Technology To Detect Excessive Water Discharges From The Relief Valve
- Alert features available with add-on sensor connection kit
- Lead free copper silicon alloy body
- NPT inlet and outlet connections
AM-1 series adjusts, maintains, and limits the hot water temperature settings to provide comfort and protect equipment at home. Designed to prevent scalding water and legionella bacteria growth by storing water at 140 degree F and higher. Delivers safe and comfortable water temperatures out of the faucet at 120 degree F.
- Offers constant water temperature under changing operating conditions
- Temperature is limited at any point and if cold water supply is interrupted, flow reduction occurs in seconds
- Designed for easy maintenance and Teflon coating prevents mineral build-up and extends life
- Provides reliable performance at minimum flow of 05 GPM and proportional valve for simultaneous control of hot and cold
- Features dual purpose mixing or diverting values
- Lead free products have products numbers end in LF
- Available temperature gauge adapter in lead-free brass material with EPDM O-ring
- Maximum safe operating pressure (psi)150 psi
- Minimum flow rate (GPM) 0.5 GPM
- Includes check valves on hot and cold ports
The Emerson 1361-102 is a 2-wire valve for zoning Hydronic systems up to 50 PSI. This valve is designed for 0.75 in. I.D. tubing, and features built-in auxiliary contacts to control burner or circulator relay. This zone valve is for 3/4 in. tubing.
- Quiet operation
- Valve position shown at all times
- Auxiliary contacts to control a burner or circulator relay
- Motor can be removed from valve without draining systems
- 240F maximum water temp
- Time cycle: open 45 seconds, closed 45 seconds
Danfoss -- Straight Valve Body. For Ra2000 Units. Connection: 3/4" Npt.
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. For use in hydronic controls. Press-connect fittings.
- All models may be installed without disassembling the valve
- Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure
- Valve returns to automatic position when power is restored
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Silent motor and system operation
- Compatibility with a full range of thermostats
- Quality seal and significantly increases service life
- Robust metal-to metal connection
2-Way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
Danfoss -- Straight Valve Body. For Ra2000 Units. Connection: 1/2" Npt.
Single zone switching relay should be standard equipment for every installer. No matter what type of job, our single zone switching relay replaces every brand made by every manufacturer. The single zone switching relays are compatible with conventional and programmable thermostats, ul listed and come with a 3-year warranty. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups.
- Compact design
- UL and CSA approved
- 3 year warranty
- Fuse protected
- Simplified wiring for ease of installation
- Premium sealed relays
Nibco ACR Copper 90degree Long Radius Elbow
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Mfg #9080400
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- with stop
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
Nibco Copper Coupling. Mfg #9020400
- 0.75" Inlet
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Without Stop
Zone Panel for conventional and heat pump applications. Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer through four easy steps.
- Standard checkout procedure
- Robust push terminals
- Common-Sense LEDs
- Clean, professional installation
2-Way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
3 ZONE VALVE CONTROL
- Controls (3) Zones
- Built in Switchable Priority
- External Indicator Lights
- Simplified Wiring
Taco Switching Relays combine clearly labeled PC board layouts with advanced features that allow for total system customization. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups. All switching relays are ul listed, are compatible with conventional and programmable thermostats.
- Compact design
- UL and CSA approved
- 3 year warranty
- Fuse protected
- Simplified wiring for ease of installation
- Premium sealed relays
- Factory tested
- Isolated end switch
- Field replaceable transformer
- Built in priority
1/8 in. IPS male thread connection. Use screwdriver or coin to operate. 5 years warranty against defect.
- Air vent
- Hot water
- Valve only
- Nickel plated
- Silver
- Specifications
- Safety
- 125 psi
- Fits 1/8 in. threads
- Meets ASME standards
Nibco ACR Copper 90degree Long Radius Elbow C x C
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- Mfg #108283
- 0.88" OD
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- with stop
Taco Switching Relays combine clearly labeled PC board layouts with advanced features that allow for total system customization. External indicator lights provide instant diagnostic feedback, making a snap of service calls or new installation start-ups. All switching relays are UL Listed, are compatible with conventional and programmable thermostats.
- Compact design
- UL and CSA approved
- 3-year warranty
- Fuse protected
- Simplified wiring for ease of installation
- Premium sealed relays
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. For use in hydronic controls. Press-connect fittings.
- All models may be installed without disassembling the valve
- Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure
- Valve returns to automatic position when power is restored
- Compact construction for easy installation