Searched for "40141616"
Nibco ACR Copper Coupling
- 0.5" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #039923306944
- 0.5" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
Nibco ACR Copper Coupling
- 0.63" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #9001193
- 0.63" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
Nibco ACR Copper Coupling
- 0.75" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #039923307125
- 0.75" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
Nibco ACR Copper 90degree Elbow. 0.88" Od. Dezincification Resistant. NFPA 99 Health Care Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas). Mfg #9055600
- 0.88" Od
- Dezincification Resistant
- NFPA 99 Health Care Facilities Gas And Vacuum Systems
- Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
AM-1 series adjusts, maintains and limits the hot water temperature settings to provide comfort and protect equipment at home. Designed to prevent scalding water and legionella bacteria growth by storing water at 140 degree F and higher. Delivers safe and comfortable water temperatures out of the faucet at 120 degree F.
- Offers constant water temperature under changing operating conditions
- Temperature is limited at any point and if cold water supply is interrupted, flow reduction occurs in seconds
- Designed for easy maintenance and Teflon coating prevents mineral build-up and extends life
- Provides reliable performance at minimum flow of 05 GPM and proportional valve for simultaneous control of hot and cold
- Features dual purpose mixing or diverting values
- Lead free products have products numbers end in LF
- Available temperature gauge adapter in lead-free brass material with EPDM O-ring
- Maximum safe operating pressure (psi)150 psi
- Minimum flow rate (gpm) 0.5 GPM
- Includes check valves on hot and cold ports
Nibco ACR Copper Coupling
- 0.25" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
- Mfg #9000353
- 0.25" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
Nibco ACR Copper 45degree Elbow. 0.88" Od. Dezincification Resistant. NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas). Mfg #9042900
- 0.88" Od
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems
- Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
Nibco ACR Copper Coupling. Mfg #9001003
- 0.38" Tubing
- Dezincification Resistant
- NFPA 99 Healthcare Facilities Gas And Vacuum Systems And The Compressed Gas Association, Pamphlet G4.1 (Medical Gas)
- With Stop
This 1/2 in. high capacity feed water pressure regulator is for use in commercial and residential hydronic heating systems to fill the boiler and piping system with water, and to maintain water pressure in the system at all times. It also provides make-up water to the system in the event of system leaks. It consists of a bronze body with union threaded inlet and NPT threaded outlet connections, a tight seating check valve, purge lever for manual purging, and a stainless steel strainer. It has high capacity performance and a simplified servicing design. It is suitable for use in the boiler feed lines of hydronic heating systems. The maximum pressure is 100 psi (6.9 bar).
- Tight seating check valve
- Purge lever
- High capacity
- Stainless steel strainer
- Union threaded inlet connection
- Used to maintain water pressure in commercial and residential hydronic heating systems at all times
- Provides make-up water to the system in the event of system leaks
Watts 1/2 IN Lead Free Anti-Siphon Pressure Vacuum Breaker Backflow Preventer Includes A Freeze Sensor For Use With Sentryplus Alert Technology To Signal Facility Personnel When Temperature Nears And Reaches The Freezing Point Available freeze sensor connection kit to activate a monitoring system that trigger alerts for low and freezing temperatures Lead free construction Replaceable seat Female NPT inlet and outlet with quarter turn shutoffs Easy internal access Mfg #T792010
- Includes A Freeze Sensor For Use With Sentryplus Alert Technology To Signal Facility Personnel When Temperature Nears And Reaches The Freezing Point
- Available freeze sensor connection kit to activate a monitoring system that trigger alerts for low and freezing temperatures
- Lead free construction
- Replaceable seat
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
Watts 3/4 IN 374A Iron Boiler Pressure Relief Valve, 30 psi, Forged Brass Inlet Features A Flood Sensor With Sentryplus Alert Technology To Detect Excessive Water Discharges From The Relief Valve Requires purchase of activation kit to activate sensor Iron body with forged bronze inlet 550,000 BTU/hr rating Non-metallic disc-to-metal seating Set pressure 30 psi Mfg #F358553
- Features A Flood Sensor With Sentryplus Alert Technology To Detect Excessive Water Discharges From The Relief Valve
- Requires purchase of activation kit to activate sensor
- Iron body with forged bronze inlet
- 550,000 BTU/hr rating
3 ZONE VALVE CONTROL
- Controls (3) Zones
- Built in Switchable Priority
- External Indicator Lights
- Simplified Wiring
The Emerson 1361-102 is a 2-wire valve for zoning Hydronic systems up to 50 PSI. This valve is designed for 0.75 in. I.D. tubing, and features built-in auxiliary contacts to control burner or circulator relay. This zone valve is for 3/4 in. tubing.
- Quiet operation
- Valve position shown at all times
- Auxiliary contacts to control a burner or circulator relay
- Motor can be removed from valve without draining systems
- 240F maximum water temp
- Time cycle: open 45 seconds, closed 45 seconds
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
The GoldTop offers a convenient, one-fits-all concept, to stock one vent for all your venting needs, between 1 and 150 psi systems. Honeywell's revolutionary patented fulcrum design offers a venting rate of 3-4 times that of other products. Used in Residential or commercial heating and cooling systems.
- Maximum safe operating pressure (psi) 150 psi
- Operating temperature range (F)240 degree F
- Male NPT connection
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
Danfoss Part # 013G8042 1/2" Or 013G8044 3/4" Solder Union Straight Valve Body For Ra2000 Units. Conforms To Ansi/Ashrae Standard 102-1983
2-way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Patent no. 5,988,201
- Light weight
- Proven durability
- Easy to install
- No clog vent
- 360 degree adjustable collar ring for installation flexibility
- Stainless steel concentrator which eliminates gurgling noise
2-Way on-off low voltage valves consist of an actuator and valve assembly for controlling the flow of hot water. Manual opener (on all models, except straight-through, normally open valves) for valve operation on power failure; valve returns to automatic position when power is restored. All models may be installed without disassembling the valve.
- Compact construction for easy installation
- Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
- Actuator motor may be replaced without removing the valve body or draining the system
- Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
Danfoss Aveo Sensors, Electronic, Sensor type. Easy To Use. Thermostatic Radiator Valve. Built in Tamper Proof. 015G4290. Mfg #015G4290
- Easy To Use
- Thermostatic Radiator Valve
- Built in Tamper Proof
- 015G4290
Danfoss Aveo Remote Sensor
- Easy To Use
- Thermostatic Sensor
- Remote Sensor
- Mfg #015G4292
- Easy To Use
- Thermostatic Sensor
- Remote Sensor
- Danfoss Aveo
AM-1 series adjusts, maintains, and limits the hot water temperature settings to provide comfort and protect equipment at home. Designed to prevent scalding water and legionella bacteria growth by storing water at 140 degree F and higher. Delivers safe and comfortable water temperatures out of the faucet at 120 degree F.
- Offers constant water temperature under changing operating conditions
- Temperature is limited at any point and if cold water supply is interrupted, flow reduction occurs in seconds
- Designed for easy maintenance and Teflon coating prevents mineral build-up and extends life
- Provides reliable performance at minimum flow of 05 GPM and proportional valve for simultaneous control of hot and cold
- Features dual purpose mixing or diverting values
- Lead free products have products numbers end in LF
- Available temperature gauge adapter in lead-free brass material with EPDM O-ring
- Maximum safe operating pressure (psi)150 psi
- Minimum flow rate (GPM) 0.5 GPM
- Includes check valves on hot and cold ports
Zone Panel for conventional and heat pump applications. Intuitive Installer setup. Easy-to-follow, digital display uses real language to guide installer through four easy steps.
- Standard checkout procedure
- Robust push terminals
- Common-Sense LEDs
- Clean, professional installation