Keystone Technology's T8 Instant Start electronic ballast is designed to operate 2 T8 lamps. Featuring 120-Volt to 277-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- 2014 DOE compliant
- Sound rated: A
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class A) non-consumer limits
- Meets ANSI standard C82.11 and C62.41
- Maximum output voltage: 600-Volt
- Maximum voltage to ground: 600-Volt
- UL, cUL Listed class P, type 1 outdoor
- Anti-striation circuitry
- Type HL
Keystone Technology's T12 rapid start electronic ballast is designed to operate 2 T12 lamps. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Maximum case temperature: 194 degree F, 90 degree C
- Meets FCC part 18 (class B) consumer limits
- Meets ANSI standard C82.11-2005 and C62.41-2001
- OCV: 300-Volt
- UL, cUL Listed (class P, type 1-outdoor)
Keystone Technologys CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamps. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, minus 18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
- Non-dimmable
Keystone Technologies T9 Rapid Start electronic ballast is designed to operate 2 Circleline lamps. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Watt ages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- UL listed (class P, type 1-outdoor)
- Remote mounting: 18 ft. maximum lead length
- Type HL
Keystone Technology's T8 Instant Start electronic ballast is designed to operate 4 T8 lamps. Featuring 120-Volt to 277-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- 2014 DOE compliant
- Sound rated: A
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class A) non-consumer limits
- Meets ANSI standard C82.11-2002 and C62.41-2002
- UL, cUL Listed, class P, type 1 outdoor
- OCV: 600-Volt
- Anti-striation circuitry
- Type HL
Keystone Technology's CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamp. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 75 degree C, 167 degree F
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz to 33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
Keystone Technologys T12 instant start electronic ballast is designed to operate 2 F40T12 fluorescent lamps. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- OCV: 600-Volt
- UL, cUL 935 listed
Keystone Technologys T9 rapid start electronic ballast is designed to operate 1 T9 lamp. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz, 40KHz-50KHz
- Lamp end-of-life protected
Circline 2-Bulb Fluorescent Electronic Ballast. 120 Volt. 22w And 32w. For Operating One Fc8t9 And Fc12t9. Normal Power Factor. Thermally Protected. Rapid Start. Mfg #IG230ELSX/T9
- 120 Volt
- 22w And 32w
- For Operating One Fc8t9 And Fc12t9
- Normal Power Factor
Keystone Technologys CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamp. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 75 degree C, 167 degree F
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
Philips Advance® Centium® Electronic Multivolt Ballast, Model #ICN2P32N. 120/277 Volt. 32w. For Operating Two F17t8, F25t8, F32t8, Fb31t8 Or Fb32t8 Bulbs Or One F40t8 Bulb. 87% Ballast Factor. Thermally Protected. 5 Wires: Blk, W, Bl, Bl, R. Instant Start. Parallel Wired. Less Than 20% Total Harmonic Distortion. Nema Qualified. Model #icn2p32n. Mfg #913710842701
- 120/277 Volt
- 32w
- For Operating Two F17t8, F25t8, F32t8, Fb31t8 Or Fb32t8 Bulbs Or One F40t8 Bulb
- 87% Ballast Factor
Philips Advance® Electronic Ballast. 120 Volt. 40w. For Operating One Or Two F30t12, F30t12es, F40t12es Or F40t12 Bulbs. 85% Ballast Factor. Thermally Protected. 8 Wires: Y, Y, Bl, Bl, R, R, W, Blk. Rapid Start. Replaces R-2s40-N. Residential Grade. Mfg #913701218101
- 120 Volt
- 40w
- For Operating One Or Two F30t12, F30t12es, F40t12es Or F40t12 Bulbs
- 85% Ballast Factor
2 lite 22W and 32W or 32W and 40W, circline ballast with sockets.
Our Keystone T12 Electric Fluorescent ballast for a 1-lamp to 2-lamp F96T12 or F96T12ES lamp. This is our 9 in. case option. This ballast has an instant start starting method with a parallel lamp connection. Ballast frequency for all listed lamps: 20 KHz to 33 KHz Specifications Power Factor: High.
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Starting method: instant start
- Input voltage: 120-277 VAC plus/minus 10%
- Halco Electronic Fluorescent Ballast T8, 2 Lamp, Instant Start, 120-277V
- Come In 2, 3, And 4 Lamp Configurations
- Feature Micro Case Design
- High Efficiency T8 Ballast Are Nema Premium And Cee Listed
- Ballast Are Mult-Volt To Accommodate 120v-277v Applications
- MFG# 50123
- Halco Electronic Fluorescent Ballast T5, 2 Lamp, Programmed Start, 120-277V
- Commercial, Industrial
- Programmed Start
- F54t5/Ho
- Fluorescent
- 49-55w
- MFG# 50144
High Efficiency Instant Start Electronic Ballast For One 32 Watt T8 Lamp 347 Volt Qhe1X32T8347Islsc 347V
High Efficiency Instant Start Electronic Ballast Two 59 Watt T8 Universal Volt Normal Ballast Factor Qhe2X59T8Unvisnsc
High Efficiency Instant Start Electronic Ballast For Three 32 Watt T8 Lamps 347 Volt Qhe3X32T8347Isnsc 347V
- 145 Total Maximum Wattage
- Instant Start
- 1.181" Height
- 9.469" Length
- 1.681" Width
- QHE 4X32T8/UNV ISH-SC
- Halco Compact Electronic Fluorescent Ballast T5 Kit, 2 Lamp, Programmed Start
- Commercial, Industrial
- Pl Double Tube - Pl26d/E/G24q
- Programmed Start
- Electronic Compact Fluorescent Kit
- MFG# 52106
The Sylvania Quicktronic High Efficiency 2-lamp, 32-Watt T8, instant Start electronic ballast operates at 120-277-Volt. The ballast has a normal ballast factor. The ballast also carries a type CC rating.
- Instant start
- 2 lamp
- 32-Watt
- Electronic
- CC rated
- Normal BF
High Efficiency Instant Start Electronic Ballast For Four 32 Watt T8 Lamps 347 Volt Qhe4X32T8347Isnsc 347V
The Sylvania Quicktronic High Efficiency energy-saving electronic T8 ballasts save up to 6% over standard electronic ballasts without compromising light output or lamp life. The added energy savings also provides for a quicker payback. This particular ballast operates at 120-Volt to 277-Volt, has a normal ballast factor and operates up to 2, 59-Watt, 8 ft. T8 lamps.
- High efficiency systems over 90% efficient
- Instant start
- Universal-voltage (120-Volt to 277-Volt)
- Virtually eliminates lamp flicker
- RoHS compliant
- Lead-free solder and manufacturing
- High power factor
- Low harmonic distortion
- Normal ballast factor