Circuit Breakers
Siemens Triplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Triplex Circuit Breaker provides overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.
- (1) 30 amp double pole and (2) 20 amp single pole circuit breakers
- Requires 2 in. breaker space
- Plug in type
- Space saving design allows 2 poles to fit in a 1 in. panel space
- 10K AIC series rating
- 120/240 VAC
- UL listed
- CSA certified
- HACR rated
- Designed for residential/commercial applications
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger, and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (1) 2 pole 20 Amp and (1) 2 pole 30 Amp
- Number of poles - 4
- Trip type - independent
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240V
- Wire size - #14-4 AWG Cu/Al at 60C or 75C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger, and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 2 pole 30 Amp
- Number of poles - 4
- Trip type - independent
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240V
- Wire size - #14-4 AWG Cu/Al at 60C or 75C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Siemens Quadplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Quadplex Circuit Breakers provide overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Quad breakers provide two sets of common trip, 2-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.
- Quad breakers provide two sets of common trip, 2-pole breakers
- 1) 30-Amp Double Pole and (1) 30-Amp Double Pole
- Compatible with Siemens panels that allow CTL type QT breakers
- Plug-in design enables hassle-free installation
- Requires 2 inch breaker space
- Meets UL, CSA and ANSI safety requirement. SWD and HACR Rated
- Designed to protect the home's wiring from high temperatures caused by excess current
Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.
- Pushmatic Replacement Breaker : P230
- 2 Pole breaker in 1- ½" body
- Intertek ETL Listing to UL Standard 489 for US and Canada - Molded case circuit breakers
- Manufactured New by Connecticut Electric
- Bolt On Type
- 30 AMP - 120/240 VAC - 10,000 AIC
- May also be branded as Bulldog (i.e. Bulldog P230)
This 200 Amp Double-Pole Main Breaker Conversion Kit is designed to convert a main lug load center into a main breaker load center. The breaker has a maximum load of 240-Volt and is suitable for use in 200 Amp load centers. This ANSI-certified and CSA and UL-listed converter is compatible for use in both Murray and Siemens' Ultimate Load Centers. Allows for a means of disconnect in a single switch for all circuits in your Siemens Load Center.
- Use to convert a main lug load center to a main breaker load center
- Bolt on main breaker designed for use in ultimate load centers
- Interrupting rating of 22KA 120/240V AC
- ANSI certified and CSA and UL listed
Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.
- Pushmatic Replacement Breaker : P220
- 2 Pole breaker in 1- ½" body
- Intertek ETL Listing to UL Standard 489 for US and Canada - Molded case circuit breakers
- Manufactured New by Connecticut Electric
- Bolt On Type
- 20 AMP - 120/240 VAC - 10,000 AIC
- May also be branded as Bulldog (i.e. Bulldog P220)
Siemens Triplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Triplex Circuit Breaker provides overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.
- (1) 50 amp double pole and (2) 20 amp single pole circuit breakers
- Requires 2 in. breaker space
- Plug in type
- Space saving design allows 2 poles to fit in a 1 in. panel space
- 10K AIC series rating
- Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers
- UL listed
- CSA certified
- HACR rated
- Designed for residential/commercial applications
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 1-pole 20 Amp and (1) 2-pole 40 Amp
- Number of poles - 4
- Trip type - independent
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt at 40 Amp, 120-Volt at 20 Amp
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - 2 - single-pole 20 Amp, one 2-pole 50 Amp
- Number of poles - 4
- Trip type - common
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60C or 75C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Siemens Triplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Triplex Circuit Breaker provides overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.
- (1) 30 Amp Double Pole and (2) 15 Amp Single Pole Circuit Breakers
- Requires 2 inch breaker space
- 10,000 AIC rated
- Space saving design allows 2 poles to fit in a 1 in. panel space
- 10K AIC series rating
- 120/240 VAC
- UL listed
- CSA certified
- HACR rated
- Designed for residential/commercial applications
This 150 Amp Double-Pole Main Breaker Conversion Kit is designed to convert a main lug load center into a main breaker load center. The breaker has a maximum load of 240-Volt and is suitable for use in 150 Amp load centers. This ANSI-certified and CSA and UL-listed converter is compatible for use in both Murray and Siemens' Ultimate Load Centers. Allows for a means of disconnect in a single switch for all circuits in your Siemens Load Center.
- Use to convert a main lug load center to a main breaker load center
- Bolt on main breaker designed for use in ultimate load centers
- Interrupting rating of 22KA 120/240V AC
- Wire range #1 - 300 kcmil cu/al
- ANSI certified and CSA and UL listed
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (1) 2-pole 20 Amp and (1) 2-pole 30 Amp
- Number of poles - 4
- Trip type - common
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Murray offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Murray offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- Single pole, 20 Amp 120-Volt type MP circuit breaker
- 10,000 AIC interrupting rating
- Murray type MP circuit breakers provide easy plug-in connections in Murray enclosures and the time saving insta-wire feature
- Compatible with Murray rock solid load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
- Provides a manual means of energizing and de-energizing a circuit
- Easy plug in connections in Murray load centers
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 1-pole 20 Amp and (1) 2-pole 30 Amp
- Number of poles - 4
- Trip type - independent
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt at 30 Amp, 120-Volt at 20 Amp
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger, and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (1) 2 pole 30 Amp and (1) 2 pole 50 Amp
- Number of poles - 4
- Trip type - independent
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240V
- Wire size - #14-4 AWG Cu/Al at 60C or 75C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Siemens Quadplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Quadplex Circuit Breakers provide overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Quad breakers provide two sets of common trip, 2-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.
- Quad breakers provide 2-sets of common trip, 2-pole breakers
- (1) 30 amp double pole and (1) 50 amp double pole
- Compatible with siemens panels that allow CTL type QT breakers
- Plug-in design enables hassle-free installation
- Requires 2 in. breaker space
- Meets UL, CSA and ANSI safety requirement. SWD and HACR rated
- Designed to protect the home's wiring from high temperatures caused by excess current
Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.
- Pushmatic Replacement Breaker : P2020
- 2 - 1 Pole breakers in 1- ½" body
- Intertek ETL Listing to UL standard 489 for US and Canada-molded case circuit breakers
- Manufactured New by Connecticut Electric
- Bolt On Type
- 20/20 AMP - 120 VAC - 10,000 AIC
- May also be branded as Bulldog (i.e. Bulldog P2020)
- Class CTL circuit breaker for use in CTL listed panels
Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished circuit breakers should never be used.
- Pushmatic Replacement Breaker : P120
- 1 Pole breaker in 1- ½" body
- Intertek ETL Listing to UL Standard 489 for US and Canada - Molded case circuit breakers
- Manufactured New by Connecticut Electric
- Bolt On Type
- 20 AMP - 120 VAC - 10,000 AIC
- May also be branded as Bulldog (i.e., Bulldog P120)
Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.
- Pushmatic Replacement Breaker : P1515
- 2 - 1 Pole breakers in 1- ½" body
- Intertek ETL Listing to UL standard 489 for US and Canada-molded case circuit breakers
- Manufactured New by Connecticut Electric
- Bolt On Type
- 15/15 AMP - 120 VAC - 10,000 AIC
- May also be branded as Bulldog (i.e. Bulldog P2020)
- Class CTL circuit breaker for use in CTL listed panels
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (1) 2-pole 30 Amp and (1) 2-pole 40 Amp
- Number of poles - 4
- Trip type - common
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
This 100 Amp Double-Pole Main Breaker Conversion Kit is designed to convert a main lug load center to a main breaker load center. The breaker has a maximum load of 240-Volt and is suitable for use in 100 Amp load centers. This ANSI-certified and CSA and UL-listed converter is compatible for use in both Murray and Siemens' Ultimate Load Centers. Allows for a means of disconnect in a single switch for all circuits in your Siemens Load Center.
- Use to convert a main lug load center to a main breaker load center
- Bolt on main breaker designed for use in ultimate load centers
- Interrupting rating of 22KA 120/240V AC
- ANSI certified and CSA and UL listed
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (1) 2-pole 30 Amp and (1) 2-pole 50 Amp
- Number of poles - 4
- Trip type - common
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Carry listing for HACR applications
- Breaker has a rejection tab feature