The Square D by Schneider Electric Homeline Single-Pole Tandem Circuit Breaker consists of (2) single-pole, 20 Amp breakers in 1 pole space. It is used for overload and short-circuit protection of your electrical system. This breaker is compatible with Homeline load centers and CSED devices. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 Air. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Plug-on design, easy to install
- Compatible with Square D Homeline load centers and CSED devices
- 120/240-Volt AC
- 10,000 AIR
- Limited lifetime warranty
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 15 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with Eaton's line of whole house surge devices. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/4
The Square D by Schneider Electric Homeline 40 Amp Two-Pole Circuit Breaker is used for overload and short-circuit protection of your electrical system. This breaker is compatible with Homeline load centers and CSED devices. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 40 Amp two-pole circuit breaker
- Plug-on design, easy to install
- Compatible with Square D Homeline breaker boxes and CSED devices
- This breaker needs 2 spaces in a breaker box for installation
- 120/240-Volt AC
- 10,000 AIR
- Limited lifetime warranty
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- 2-pole, 40 Amp, 240-Volt type QP circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your homes electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- Twin single pole, 15 Amp 120-Volt type QT interchangeable circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QT circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your homes electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- 2-pole, 60 Amp, 120-Volt/240-Volt type QP circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
The Eaton Cutler-Hammer 15 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use lighting fixtures. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/2
The Eaton Cutler-Hammer 20 Amp 3/4 in. Duplex Double-Pole Type CHT Current-Limiting Circuit Breaker is designed to protect your home's wiring from overheating or short-circuiting. The UL listed breaker has a maximum load of 240-Volt and trips to the off position. This breaker is compatible with load centers marked CHT.
- Breakers are plug-on
- Requires one 3/4 in. space
- Switching duty rated
- Heating, air conditioning and refrigeration (HACR) rated
The Eaton Cutler-Hammer 20 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use with dishwashers, waste disposals, refrigerators, freezers, washing machines, televisions and window air conditioners. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 12/2
General Electric Breaker. Single Pole Thin Breaker. Mfg #THQP-120
- 120/240 Vac
- 20A
- HACR/SWD Rated
- Requires .5 Of 1" Space
The Square D by Schneider Electric Homeline 100 Amp Two-Pole Circuit Breaker is used for overload and short-circuit protection of your electrical system. This breaker is compatible with Square D Homeline load centers and CSED devices. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 100 Amp two-pole circuit breaker
- Plug-on design, easy to install
- Compatible with Square D Homeline breaker boxes and CSED devices with 2 spaces
- 120/240-Volt AC
- 10,000 AIR
- Limited lifetime warranty
- ANSI certified and UL Listed
The Eaton Cutler-Hammer 30 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with built-in oven, range top, clothes dryer and water heater. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 10/3
Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits, including connected cords. They meet the requirements of the UL Standard for Safety, UL 1699 for devices that reduce the effects of persistent arcing faults that may pose a risk of fire under certain conditions. Arcing creates high intensity heating at the point of the arc resulting in burning particles that may over time ignite surrounding material, such as wood framing or insulation. The CHFCAF120 is a 20 Amp combination type breaker that includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets.
- Combination type includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- Branch feeder mitigates parallel arcing faults, which produce the most energy of all arcing faults, in the complete circuit including connected cords for enhanced safety
- For use in type CH load centers
- Amp: 20 Amp
- Interrupt rating-10 kAIC
- Voltage rating is 120-Volt/240-Volt
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- Standard LED indicates 1 of 7 trip codes to simplify circuit diagnostics
General Electric Thick Breaker
- 120/240 Vac
- 30A
- HACR Rated
- Requires Two 1" Spaces
- Double Pole Thick Breaker
- Mfg #THQL-2130
- 120/240 Vac
- 30A
- HACR Rated
- Requires Two 1" Spaces
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 10 year limted warranty
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 40 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 40 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits, including connected cords. They meet the requirements of the UL Standard for Safety, UL 1699 for devices that reduce the effects of persistent arcing faults that may pose a risk of fire under certain conditions. Arcing creates high intensity heating at the point of the arc resulting in burning particles that may over time ignite surrounding material, such as wood framing or insulation. The BRN120AF is a 20 Amp combination type breaker that includes all the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets.
- Fire-guard model AFCI recognizes the unique current and/or voltage signatures associated with arcing faults and efficiently interrupts the circuit to reduce fire hazards
- Branch feeder mitigates parallel arcing faults which produce the most energy of all arcing faults in the complete circuit including connected cords for enhanced safety
- Combination type includes all the protection of the branch feeder plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- For use in type BR load centers
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- Single pole, 20 Amp 120-Volt type QP interchangeable circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
General Electric Circuit Breaker
- 120/240 Vac
- 30A
- HACR Rated
- Requires One 1" Space
- Double Pole Thin Breaker
- Mfg #THQP-230
- 120/240 Vac
- 30A
- HACR Rated
- Requires One 1" Space
General Electric Circuit Breaker
- 120/240 Vac
- 40A
- HACR Rated
- Requires One 1" Space
- Double Pole Thin Breaker
- Mfg #THQP-240
- 120/240 Vac
- 40A
- HACR Rated
- Requires One 1" Space
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your homes electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- 2-pole, 100 Amp, 240-Volt Type QP circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
Siemens Triplex Type QT breakers are a 1/2 in. frame per pole and are suitable for use in Siemens panels that allow CTL type QT breakers. Triplex Circuit Breaker provides overload and short circuit protection meant to protect your home's wiring from high temperatures caused by excess electrical currents. All type QT circuit breakers are plug-in style and load terminals are provided with the units. Triplex breakers provide 1 inner 2-pole/2 outer 1-pole breakers. They are rated for 120/240-Volt AC and calibrated for 40C maximum ambient applications. The standard interrupting rating is 10k AIC.
- (1) 30 amp double pole and (2) 20 amp single pole circuit breakers
- Requires 2 in. breaker space
- Plug in type
- Space saving design allows 2 poles to fit in a 1 in. panel space
- 10K AIC series rating
- 120/240 VAC
- UL listed
- CSA certified
- HACR rated
- Designed for residential/commercial applications
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer 15/15 Amp 1 in. Duplex Type BD Circuit Breaker is also known as tandem or circuit limiting breaker. This style of breaker will only fit into load center bus stabs that are notched to accommodate the rejection clip built into the bus bar contact on the breaker. This is a code requirement that limits the number of breakers that can be installed into a load center.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 15 Amp
- Duplex 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Carry listing for HACR applications
- Breaker has a rejection tab feature