Searched for "39121601"
The Square D by Schneider Electric QO Value-pack 125 Amp 24-Space 24-Circuit Indoor Convertible Main Lug Load Center for Plug-on Neutral breakers includes the cover, ground bar and a selection of breakers. It is UL Listed for residential, commercial and industrial power distribution. This load center is built with a shielded, copper bus bar that is plated for reliability. QO load centers are tested and Listed only for QO circuit breakers. QO load centers are the World's Finest designed with industry leading features for flexible application. QO load centers include features engineered for fast installation and wire savings.
- Engineered for a quick plug-on neutral breaker connection on every circuit, fewer connections, faster installation and no pigtails frees up gutter space
- Includes PK15GTA ground bar, 3 QO120 QO 20 Amp single-pole circuit breakers, 2 QO230 QO 30 Amp double-pole circuit breakers and a factory-included flush cover
- Accommodates plug-on-secondary surge arrestor (sold separately)
- Overhead/underground feed simply by rotating the device before installing
- Single phase
- Rated 120/240-Volt AC and 65,000 air short circuit current rating
- Designed with straight-in mains to save expensive cable and time
- Split branch neutral with terminal screws backed out offering with up to 50% more terminals than UL requires increases wiring flexibility saving installation time and simplifies wiring
- Thermoplastic interior is among the most rugged in the industry
- Slot/Square D screws let you use either standard flat blade screwdriver or square-head driver for positive drive and proper torque
- Convertible mains allow you to meet changing job site requirements by field converting main breaker load centers to main lugs and vice versa
- For protection from damage or theft on the job site, interiors can be easily removed with a single captive screw
- 3 ground bar mounting locations (left, right and end) let you pick the easiest spot to wire
Connecticut Electric manufactures new high quality replacement circuit breakers for Pushmatic load center that accept Pushmatic style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.
- Pushmatic Replacement Breaker : P1515
- 2 - 1 Pole breakers in 1- ½" body
- Intertek ETL Listing to UL standard 489 for US and Canada-molded case circuit breakers
- Manufactured New by Connecticut Electric
- Bolt On Type
- 15/15 AMP - 120 VAC - 10,000 AIC
- May also be branded as Bulldog (i.e. Bulldog P2020)
- Class CTL circuit breaker for use in CTL listed panels
Connecticut Electric manufactures new high quality replacement circuit breakers for Stab-Lok load centers that accept NC style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished ones should never be used.
- Federal Pacific Replacement Breaker : NC30
- 1 Pole breaker in ½" thin body - NC Style
- Intertek ETL listing to UL standard 489 for US and Canada-molded case circuit breakers
- Manufactured New by Connecticut Electric
- For use in Stab-Lok circuit breaker panels
- Plug in type
- 30 AMP- 120 VAC - 10,000 AIC
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position
The Square D by Schneider Electric QO 15 Amp Single-Pole Tandem Circuit Breaker is intended for overload and short-circuit protection of your electrical system. This breaker offers 2 circuits in the space of just 1 and is compatible with Square D QO load centers, CSED devices, and NQOD panel boards. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. All QO circuit breakers are equipped with the exclusive Visi-Trip indicator. When a QO Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between in OFF and in ON and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 42 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection.
- QO 2-15 Amp one-pole tandem circuit breaker
- Plug-on design, easy to install
- Compatible with Square D QO breaker boxes, CSED's and NQOD panel boards with 1 space
- For installation in 120/240-Volt AC systems
- 10,000 AIR
- Limited lifetime warranty
The QO 20 Amp Tandem Single-Pole Replacement Circuit Breaker offers 2 poles in the space of 1. The replacement breaker is for use in old-style, non-class CTL Square D QO load centers and has a maximum load of 240-Volt. The breaker features Qwik-Open and a Visi-Trip indicator to easily identify a tripped breaker.
- Square D QO 2-20 Amp one-pole tandem circuit breaker
- For installation in old-style, non-class CTL QO load centers
- Compatible with Square D QO breaker boxes and CSED devices with 1 space
- QO 20 Amp tandem one-pole replacement circuit breaker offers 2 poles in the space of 1 as the replacement breaker is for use in old-style, non-class CTL QO load centers and has a maximum load of 240-Volt
- Breaker features Qwik-Open and a Visi-Trip indicator to easily identify a tripped breaker
- Trip thermally (in an overload situation) or magnetically (under a short circuit situation)
- Quick make - quick break mechanism
- Visi-trip indicator
- 10,000 AIR
- For installation in 120/240-Volt AC systems
- UL Listed
General Electric Breaker
- 120/240 Vac
- 30A
- HACR/SWD Rated
- Requires .5 Of 1" Space
- Single Pole Thin Breaker
- Mfg #THQP-130
- 120/240 Vac
- 30A
- HACR/SWD Rated
- Requires .5 Of 1" Space
The GE Q-Line 40 Amp 1 in. Double-Pole Circuit Breaker has a case made of heat-resistant thermoset for stability and structural integrity. The unit has tin-plated copper stabs to create reliable, permanent and corrosion-resistant connections. The circuit breaker has a dedicated calibration screw which is cemented to prevent shifting. The attached screw creates a stable calibration for optimum performance.
- THQP circuit breakers can only be used in 1/2 in. compatible GE load centers
- Tin-plated copper stabs create reliable, permanent and corrosion-resistant connections
- Box type terminals
- Calibration screw is cemented to prevent shifting
- Case is made of heat-resistant thermoset for stability and structural integrity
- Trips to the center position
- Meets NEMA standards
- ANSI certified and CSA and UL Listed
With a focus on improved safety, revolutionary design and ease of installation, Leviton takes the load center into the 21st century. Leviton offers a full line of accessories to meet every need when installing the Leviton Load Center. Locking devices, lugs, ground and neutral bar kits, conduit hubs, sealing rings and more are all available to ensure an accurate and quick installation.
- Designed for use with Leviton load center panels
- Cover empty branch breaker positions
- Sleek and appealing design covers removed dead front twist-outs
- 10-year limited warranty
- Compatible with Leviton brand load center electrical panels
Connecticut Electric manufactures new high quality replacement circuit breakers for Zinsco load centers that accept Zinsco Q style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished circuit breakers should never be used.
- Zinsco Replacement Circuit Breaker : Q20
- 1 Pole breakers in ¾" body
- Intertek ETL listing to UL standard 489 for US and Canada-molded case circuit breakers
- Manufactured New by Connecticut Electric
- Plug in type
- 20 AMP - 120 VAC - 10,000 AIC
- May also be branded as Sylvania (i.e. Sylvania Q15)
The Square D QO 40 Amp 1-1/2 in. Double-Pole Circuit Breaker is compatible with QO load centers, QO enclosures and NQOD panel boards. The breaker features a Visi-Trip indicator to easily identify a tripped circuit in the load center. This circuit breaker has a maximum load of 240-Volt with a 10,000 AIR and uses a thermal-magnetic tripping mechanism.
- Square D QO 40 Amp two-pole circuit breaker
- QO 40 Amp two-pole circuit breaker contains a thermal-magnetic tripping mechanism and has a two-pole common trip and the breaker features a visi-trip indicator to easily identify the tripped circuit in the load center
- Breaker features a visi-trip indicator to easily identify a tripped circuit in the load center this circuit breaker has a maximum load of 240-Volt with a 10,000 AIR and uses a thermal-magnetic tripping mechanism
- Use for overload and short-circuit protection of your electrical system
- 2-pole with a common trip
- Compatible with Square D QO load centers and CSED devices with 2 spaces
- 10,000 AIR
- 120/240 VAC
- ANSI certified and UL Listed
- Limited lifetime warranty
The Square D by Schneider Electric Homeline 70 Amp Two-Pole Circuit Breaker is used for overload and short-circuit protection of your electrical system. This breaker is compatible with Square D Homeline load centers and CSED devices. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 70 Amp two-pole circuit breaker
- Plug-on design, easy to install
- Compatible with Square D Homeline breaker boxes and CSED devices
- For installation in 120/240-Volt AC systems
- 10,000 AIR
- Limited lifetime warranty
30 Amp General Electric Circuit Breaker
- Thqb Series Breaker
- Bolt-On
- Double Pole
- 120/240 VAC
- Mfg #THQB2130
- Thqb Series Breaker
- Bolt-On
- Double Pole
- 120/240 VAC
50 Amp General Electric Circuit Breaker
- Thqb Series Breaker
- Bolt-On
- Double Pole
- 120/240 VAC
- Mfg #THQB2150
- Thqb Series Breaker
- Bolt-On
- Double Pole
- 120/240 VAC
General Electric Thick Breaker
- 120/240 Vac
- 125
- HACR Rated
- Requires Two 1" Spaces
- Double Pole Thick Breaker
- Mfg #THQL-21125
- 120/240 Vac
- 125
- HACR Rated
- Requires Two 1" Spaces
The Square D by Schneider Electric Homeline Quad-Pole Tandem Circuit Breaker consists of (2) single-pole, 20 Amp and (1) double-pole, 50 Amp breakers. Requiring only 2 pole spaces, it is used for overload and short-circuit protection of your electrical system. This breaker is compatible with Square D Homeline load centers and CSED devices. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 2-20 Amp single-pole 1-50 Amp double-pole quad tandem circuit breaker
- Plug-on design, easy to install, requires 2 spaces
- Compatible with Square D Homeline breaker boxes and CSED devices
- For installation in 120/240-Volt AC systems
- 10,000 AIR
- Limited lifetime warranty
Connecticut Electric manufactures new high quality replacement circuit breakers for Zinsco load centers that accept Zinsco RC style circuit breakers. Circuit breakers should only be replaced with new tested and Safety Agency Listed circuit breakers. Used or refurbished circuit breakers should never be used.
- Zinsco Replacement Circuit Breaker : R3830
- 2 - 1 Pole breakers in ¾" body (AKA: twin, duplex, tandem)
- Intertek ETL listing to UL standard 489 for US and Canada-molded case circuit breakers
- Manufactured New by Connecticut Electric
- Plug in type
- 30/30 AMP - 120 VAC - 10,000 AIC
- May also be branded as Sylvania (i.e. Sylvania R3815)
Square D by Schneider Electric Homeline 15 Amp 1-pole Dual Function Circuit Breaker is a space and labor saving device, engineered to meet prevailing NEC requirements. This device combines 2 critical technologies; Combination Arc Fault protection and Ground Fault protection (class A) in a single, easy-to-install device. The NEC now requires both Combination Arc Fault and Ground Fault protection on all 1-Pole, 15 Amp and 20 Amp kitchen and laundry circuits. Prior to the release of this new device, a contractor or homeowners only choice would have been to use a Combination Arc Fault circuit breaker in conjunction with an expensive, bulky ground fault receptacle. The new dual function circuit breakers help reduce cost and eliminate the hassle of using 2 separate devices to provide this essential protection. It's a win for contractors and homeowners alike. Like all Square D CAFI circuit breakers, it is integrated with time saver diagnostics, a unique feature that provides additional circuit information and minimizes troubleshooting at the touch of a button.
- Square D Homeline 15 Amp Single-Pole Dual Function (CAFCI and GFCI) Circuit Breaker
- Compatible with all Square D Homeline breaker boxes with 1 space
- NEC 2020/2023/2026 Compliant
- 10000 AIR
- ANSI certified and UL Listed
- Limited lifetime warranty
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 25 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 25 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
The QO 60 Amp 1-1/2 in. Double-Pole Circuit Breaker has a common trip with a maximum load of 240-Volt. The breaker features Qwik-Open and a Visi-Trip indicator to easily identify a tripped circuit in the load center. This circuit breaker uses a thermal-magnetic tripping mechanism and has a 10,000 AIR. This QO breaker is compatible with Square D's QO breaker boxes and CSEDs with 2 spaces.
- Square D QO 60 Amp two-pole circuit breaker
- QO 60 Amp two-pole circuit breaker contains a thermal-magnetic tripping mechanism and has a two-pole common trip and the breaker features a visi-trip indicator to easily identify the tripped circuit in the load center
- Breaker features a visi-trip indicator to easily identify a tripped circuit in the load center this circuit breaker has a maximum load of 240-Volt with a 10,000 AIR and uses a thermal-magnetic tripping mechanism
- Install for overload and short-circuit protection of your electrical system
- 2-pole with a common trip
- Compatible with Square D QO breaker boxes and CSED devices with 2 spaces
- 10,000 AIR
- 120/240 VAC
- ANSI certified and UL Listed
The Square D by Schneider Electric QO 15 Amp Single-Pole Combination Arc-Fault Circuit Interrupting (CAFCI) Circuit Breaker is for use to help protect your wires from arcing faults and is intended for overload and short-circuits protection of your electrical system. Now standard in all Square D brand CAFCI circuit breakers, Time-Saver Diagnostics provide advanced trip indication technology, helping identify the type of fault that has occurred faster. Time-Saver Diagnostics helps take away the guess work and provides diagnostic assistance by identifying the type of fault that last occurred. It saves money by reducing troubleshooting time, simple to use, accurate and reliable. On top of that, all QO circuit breakers are equipped with the exclusive Visit-Trip indicator. When a QO Visit-Trip circuit breaker trips, the handle snaps to a midpoint position between OFF/ON and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 42 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection.
- Square D QO 15 Amp single-pole combination AFCI circuit breaker
- Compatible with Square D QO breaker boxes, CSED's and NQOD panel boards
- This breaker needs 1 space in a breaker box for installation.
- 120-Volt AC
- 10,000 AIR
- Limited lifetime warranty
General Electric Circuit Breaker
- 120/240 Vac
- 50A
- HACR Rated
- Requires One 1" Space
- Double Pole Thin Breaker
- Mfg #THQP250
- 120/240 Vac
- 50A
- HACR Rated
- Requires One 1" Space
Eatons Cutler-Hammer Type CH circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). Our CH breakers are 3/4 in. wide and trip to the off position. They are available in 1, 2 or 3 poles from 10 to 150 Amp. In addition, arc fault and ground fault breakers are available in the Type CH line. All our Type CH breakers come with a lifetime warranty and are made exclusively for Cutler-Hammer Type CH Load centers.
- 2-pole
- 125 Amp
- Quad breaker
- Lifetime warranty
The Eaton Cutler-Hammer 15 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use lighting fixtures. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/2