Ignition Boards & Modules
Direct Replacement 2-in-1 Air Handler control for Carrier Single Stage Air Handler with PSC Blowers. Replaces Carrier HK61EA002 and HK61EA006. Direct Replacement Makes Install Quick and Easy.
- Fast drop-in OEM mounting and wiring
- Factory wiring for inline connector or spade terminals
- Dipswitch selectable blower off delay
- Replaces carrier HK61EA002 and HK61EA006
York Direct Replacement Integrated Furnace Control Single Stage Hot Surface Ignition. For 120V Ignitors. Replaces York , 265901, 265902, 539617, S1-03100662000, S1-03101250000, S1-03101266000, S1-03101267000, S1-03101267001, S1-03101284000, S1-03101933000,S1-03101972000, S1-03101973000, S1-03109167000, S1-33102956000, S1-33103010000, White-Rodgers 50A56-242, 50A56-243.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Goodman Direct Replacement Integrated Furnace Control Single Stage Hot Surface Ignition for 120V Ignitors. Replaces Goodman 0130F00005, 0130F00005S, B1809926, B1809926S, PCBBF110, PCBBF110S, PCBBF112, PCBBF112S, PCBBF123, PCBBF123S, White-Rodgers 50T55-289, 50A55-289. Diagnostic LED indicators streamline installation.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Trane Direct Replacement Integrated Ignition Control. Two Stage Direct Spark Ignition with 45 or 0 Second Cool Fan Off Delay. Used In Commercial Rooftop and Package Units. Also See F50N02-820 Adaptor Board.
- Replaces standard and adaptor board style controls
- For direct spark systems
- Integrated model controls fan functions and provides burner supervision
- 2-stage
Trane Direct Replacement Non-Integrated Ignition Module Single Stage Hot Surface Ignition for 120-Volt Ignitors Used in Commercial Rooftop and Package Unit. Also Replaces Trane Kit 17852. Applications for Hot Surface Ignition Systems.
- Replaces standard and adaptor board style controls
- For hot surface ignition systems
- Non-integrated model provides burner supervision
- 1-stage
- 120 Vac hot surface ignition
Lennox Direct Replacement Proven Pilot Spark Ignition Module for Single Stage Applications. Features LED for System Diagnostics, Order 50D50-843 for Module Only. Replaces Lennox 30W33 Kit.
- Plug in program keys for quick selection of factory timings
- Microprocessor-based ignition control
- Works with single rod or dual rod remote sensor
- Provides ignition, proof of ignition and precise timings
- LED diagnostic indicator
- For use in natural and LP gas applications
Trane Direct Replacement Integrated Ignition Control. Two Stage Direct Spark Ignition with 80 or 0 Second Cool Fan Off Delay, Used In Commercial Rooftop and Package Units. Also See F50N02-820 Adaptor Board.
- Replaces standard and adaptor board style controls
- For direct spark systems
- Integrated model controls fan functions and provides burner supervision
- 2-stage spark ignition
Goodman Direct Replacement 2-Stage AC or Heat Pump Unitary Control for PSC or ECM Outdoor Fan Motors and Single-Phase Compressors Up to 5-tons. Works With HVAC Legacy 24V or 4 Wire Communicating Systems. Replaces PCBGR102(S) and 03(S), PCBHR102(S), 103(S), 104(S).
- Direct OEM replacement
- Works with HVA/C legacy 24-Volt or 4 wire communicating systems
- 2-stage
- A/C or heat pump control
Goodman Direct Replacement Two Stage Air Handler Control for2-Stage Variable Speed Blowers for HVAC Legacy 24-Volt or 4 Wire Communicating Systems. Replaces PCBJA101(S), 102(S), 103(S), 104(S). This control is designed for variable speed inducers and blowers on communicating or legacy systems.
- 48C Goodman style two stage control designed for variable speed inducers and blowers on communicating or legacy systems
- Direct replacement OEM style control
- 2-stage
- Input 24 Vac, 60 Hz
- For use with variable speed motors
Lennox Direct Replacement Integrated Furnace Control Hot Surface Ignition for 80V Ignitors. Replaces Lennox 100925-01, 100925-02, 100925-03, 17W92, 17W9201, 23W51, 23W5101, 30W25, 30W2501, 69M08, 69M0801, 69M15, 69M1501, White-Rodgers 50A66-122, 50A66-123. Features diagnostic LED indicators streamline installation.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Universal Electronic Fan Timer for non-integrated single stage furnaces. Replaces Honeywell ST9120U1011, Isq.cm70, and Robertshaw 695-003.
- Universal control that works with SmartValve systems
- Simple pushbutton fault recall with tri-color LED indicators streamline installation and system troubleshooting
- 6-hole mounting design works with 2 or 5 screw configurations
- OEM transformer connections offer 1/4 in. and 3/16 in. terminals
- Direct replacement terminal and harness identifiers provide intuitive installation
Trane Direct Replacement 2-Stage Furnace Control Kit For 80-Volt and 120-Volt Hot Surface Ignition and Variable Speed Blower Motors and Inducers. Supersedes 50V64-743 and Includes OEM Style IGN00152 120-Volt Nitride Ignitor, Bracket, and Wire Harness. Replaces Trane KIT-15816 for XV95 Type Furnaces.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
- 2-stage 120-Volt hot surface ignition
Goodman Direct Replacement Integrated Furnace Control Hot Surface Ignition. 2-Stage for 120-Volt Ignitors and Variable Speed Motors. Works with HVAC Legacy 24-Volt or 4 Wire Communicating Systems. Replaces PCBKF101(S), 102(S), 103(S), 104(S).
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- 2-stages
- 120 Vac hot surface ignition
- For variable speed motors
Carrier / ICP Direct Replacement Integrated Furnace Control 2 Stage Hot Surface Ignition for 120V Ignitors and PSC, Variable Speed or ECMx Constant Torque Blowers. Replaces HK42FZ005, 010, 015, 017, 019, 020, 028, 040, 041, 325879-751 Kit, 1172551, 117 2809, 1184408, and Isq.cm807.
- Direct OEM replacement designed for high volume major brand controls
- Diagnostic LED indicators streamline installation and system troubleshooting
- 120-Volt air cleaner output and 120-Volt humidifier output up to 1 Amp maximum
- Factory standard safety timings and adjustable fan delay options
- Replaceable automotive style fuse
Trane Style Adaptor Board for Installing 50N02A-820 or 50N02B-820 On Commercial Rooftop and Package Units. This control is for Direct Spark systems. Ambient operating temperature is -40 degree to 175 degree F (-40 degree to 79 degree C).
- For direct spark systems
- Operating Voltage 18 to 30 VAC
- Ambient operating temperature -40 degree to 175 degree F (-40 degree to 79 degree C)
- Operating humidity 0 to 95% relative humidity (non-condensing)