Keystone Technology's T8 Instant Start electronic ballast is designed to operate 2 T8 lamps. Featuring 120-Volt to 277-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- 2014 DOE compliant
- Sound rated: A
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class A) non-consumer limits
- Meets ANSI standard C82.11 and C62.41
- Maximum output voltage: 600-Volt
- Maximum voltage to ground: 600-Volt
- UL, cUL Listed class P, type 1 outdoor
- Anti-striation circuitry
- Type HL
Keystone Technology's T8 Instant Start electronic ballast is designed to operate 4 T8 lamps. Featuring 120-Volt to 277-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- 2014 DOE compliant
- Sound rated: A
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class A) non-consumer limits
- Meets ANSI standard C82.11-2002 and C62.41-2002
- UL, cUL Listed, class P, type 1 outdoor
- OCV: 600-Volt
- Anti-striation circuitry
- Type HL
Keystone Technologys T12 instant start electronic ballast is designed to operate 2 F40T12 fluorescent lamps. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- OCV: 600-Volt
- UL, cUL 935 listed
Keystone Technology's T12 rapid start electronic ballast is designed to operate 2 T12 lamps. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Maximum case temperature: 194 degree F, 90 degree C
- Meets FCC part 18 (class B) consumer limits
- Meets ANSI standard C82.11-2005 and C62.41-2001
- OCV: 300-Volt
- UL, cUL Listed (class P, type 1-outdoor)
Keystone Technologys CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamps. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, minus 18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
- Non-dimmable
Keystone Technologys CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamp. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 75 degree C, 167 degree F
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
Keystone Technology's CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamp. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 75 degree C, 167 degree F
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz to 33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
Keystone Technologies T9 Rapid Start electronic ballast is designed to operate 2 Circleline lamps. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Watt ages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- UL listed (class P, type 1-outdoor)
- Remote mounting: 18 ft. maximum lead length
- Type HL
Keystone Technologys T9 rapid start electronic ballast is designed to operate 1 T9 lamp. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz, 40KHz-50KHz
- Lamp end-of-life protected
Philips Advance® Centium® Electronic Multivolt Ballast, Model #ICN2P32N. 120/277 Volt. 32w. For Operating Two F17t8, F25t8, F32t8, Fb31t8 Or Fb32t8 Bulbs Or One F40t8 Bulb. 87% Ballast Factor. Thermally Protected. 5 Wires: Blk, W, Bl, Bl, R. Instant Start. Parallel Wired. Less Than 20% Total Harmonic Distortion. Nema Qualified. Model #icn2p32n. Mfg #913710842701
- 120/277 Volt
- 32w
- For Operating Two F17t8, F25t8, F32t8, Fb31t8 Or Fb32t8 Bulbs Or One F40t8 Bulb
- 87% Ballast Factor
Philips Advance® Electronic Ballast. 120 Volt. 40w. For Operating One Or Two F30t12, F30t12es, F40t12es Or F40t12 Bulbs. 85% Ballast Factor. Thermally Protected. 8 Wires: Y, Y, Bl, Bl, R, R, W, Blk. Rapid Start. Replaces R-2s40-N. Residential Grade. Mfg #913701218101
- 120 Volt
- 40w
- For Operating One Or Two F30t12, F30t12es, F40t12es Or F40t12 Bulbs
- 85% Ballast Factor
Our Keystone T12 Electric Fluorescent ballast for a 1-lamp to 2-lamp F96T12 or F96T12ES lamp. This is our 9 in. case option. This ballast has an instant start starting method with a parallel lamp connection. Ballast frequency for all listed lamps: 20 KHz to 33 KHz Specifications Power Factor: High.
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Starting method: instant start
- Input voltage: 120-277 VAC plus/minus 10%
Circline 2-Bulb Fluorescent Electronic Ballast. 120 Volt. 22w And 32w. For Operating One Fc8t9 And Fc12t9. Normal Power Factor. Thermally Protected. Rapid Start. Mfg #IG230ELSX/T9
- 120 Volt
- 22w And 32w
- For Operating One Fc8t9 And Fc12t9
- Normal Power Factor
2 lite 22W and 32W or 32W and 40W, circline ballast with sockets.
- Halco Electronic Fluorescent Ballast T8, 2 Lamp, Instant Start, 120-277V
- Come In 2, 3, And 4 Lamp Configurations
- Feature Micro Case Design
- High Efficiency T8 Ballast Are Nema Premium And Cee Listed
- Ballast Are Mult-Volt To Accommodate 120v-277v Applications
- MFG# 50123
The Sylvania FS-2 is a fluorescent starter for use with F14, F15 and F20 preheat fluorescent lamps. They are also have UL and CSA classification. The starters come 100 per case and 10 per SKU.
- Fluorescent starter
- F14
- F15
- F20
- UL
- CSA
- Halco Electronic Fluorescent Ballast T8, 3 Lamp, Instant Start, 120-277V
- Come In 2, 3, And 4 Lamp Configurations
- Feature Micro Case Design
- High Efficiency T8 Ballast Are Nema Premium And Cee Listed
- Ballast Are Mult-Volt To Accommodate 120v-277v Applications
- MFG# 50170
Keystone Technology's T9 Rapid Start electronic ballast is designed to operate 1 Circleline lamp. Featuring 120-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, minus 18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Lamp end-of-life protected
- Halco Electronic Fluorescent Ballast T5, 2 Lamp, Programmed Start, 120-277V
- Commercial, Industrial
- Programmed Start
- F54t5/Ho
- Fluorescent
- 49-55w
- MFG# 50144
- Very small plastic casing
- Will power many type of lamps
- Input: 277 VAC
- Rapid start (277 and 347V)
- High power factor greater than .9
- UL (Class P) outdoor Type 1
- End of lamp life (EOL) protection for 277V and 347V models only
- Side wire feed
Keystone Technologys T12 Instant Start electronic ballast is designed to operate 1 or 2 T12 lamps. Featuring 120-Volt-277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEEC62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz
QUICKTRONIC PROStart DL40 ballasts operate DULUX L 40 lamps with maximum efficacy and high lumen output. PROStart DL40 ballasts provide over 20% more lumen output than 34T12 systems. Also, the small lamp diameter and sleek profile provide new design options and improved fixture optics.
- PROStart programmed Rapid start ballast
- QUICKSENSE ballast technology (end-of-lamp-life sensing)
- High luminous efficacy
- Virtually eliminates lamp flicker
- Quiet operation
The Sylvania Quicktroinc High Efficiency instant start DULUX L 40-Watt ballasts save up to 6 to 9% over standard electronic ballasts. They do not compromise light output or lamp life. They have universal voltage operation, 120-277-Volt.
- Instant start
- 3 lamp
- 40-Watt
- Electronic
- UL
- CSA
- 121 Total Maximum Wattage
- 2 or 1 lamp
- Programmed Rapid Start
- 0.945" Height
- 16.693" Length
- 1.157" Width
- QHE 2X54T5HO-347-480 PSN-HT