Fluorescent Ballast
Keystone Technology's T8 Instant Start electronic ballast is designed to operate 2 T8 lamps. Featuring 120-Volt to 277-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- 2014 DOE compliant
- Sound rated: A
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class A) non-consumer limits
- Meets ANSI standard C82.11 and C62.41
- Maximum output voltage: 600-Volt
- Maximum voltage to ground: 600-Volt
- UL, cUL Listed class P, type 1 outdoor
- Anti-striation circuitry
- Type HL
Keystone Technology's T8 Instant Start electronic ballast is designed to operate 4 T8 lamps. Featuring 120-Volt to 277-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- 2014 DOE compliant
- Sound rated: A
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class A) non-consumer limits
- Meets ANSI standard C82.11-2002 and C62.41-2002
- UL, cUL Listed, class P, type 1 outdoor
- OCV: 600-Volt
- Anti-striation circuitry
- Type HL
Keystone Technologys T12 instant start electronic ballast is designed to operate 2 F40T12 fluorescent lamps. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- OCV: 600-Volt
- UL, cUL 935 listed
Keystone Technology's T8 Instant Start electronic ballast is designed to operate 2 or 3 T8 lamps. Featuring 120-Volt-277-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- 2014 DOE compliant
- Sound rated: A
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class A) non-consumer limits
- Meets ANSI standard C82.11 and C62.41
- Maximum output voltage: 600-Volt
- Maximum voltage to ground: 600-Volt
- UL, cUL Listed class P, type 1 outdoor
- Anti-striation circuitry
- Type HL
Keystone Technologys CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamps. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, minus 18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
- Non-dimmable
Keystone Technology's CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamp. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 75 degree C, 167 degree F
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz to 33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
Keystone Technologys CFL rapid start electronic ballast is designed to operate 1 or 2 CFL lamp. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 75 degree C, 167 degree F
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz
- Lamp end-of-life protected
- Class P, type 1-outdoor
Keystone Technology's T12 rapid start electronic ballast is designed to operate 2 T12 lamps. Featuring 120-Volt to 277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Maximum case temperature: 194 degree F, 90 degree C
- Meets FCC part 18 (class B) consumer limits
- Meets ANSI standard C82.11-2005 and C62.41-2001
- OCV: 300-Volt
- UL, cUL Listed (class P, type 1-outdoor)
Keystone Technologies T9 Rapid Start electronic ballast is designed to operate 2 Circleline lamps. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Watt ages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- UL listed (class P, type 1-outdoor)
- Remote mounting: 18 ft. maximum lead length
- Type HL
Keystone Technologys T9 Preheat electromagnetic ballast is designed to operate 1 Circle line lamp. Featuring 120-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 32 degree F, 0 degree C
- Maximum case temperature: 194 degree F, 90 degree C
- UL, cUL 935 Listed (class P, outdoor, type 1)
- Thermal protection
Keystone Technologys T9 rapid start electronic ballast is designed to operate 1 T9 lamp. Featuring 120-Volt input and high power factor design. See the document below for complete specifications including additional lamp-Wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz, 40KHz-50KHz
- Lamp end-of-life protected
2 lite 22W and 32W or 32W and 40W, circline ballast with sockets.
This Keystone F20T12 normal power factor electronic ballast operates 1 lamp, program start applications. It operates on 120-Volt. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
Our Keystone T12 Electric Fluorescent ballast for a 1-lamp to 2-lamp F96T12 or F96T12ES lamp. This is our 9 in. case option. This ballast has an instant start starting method with a parallel lamp connection. Ballast frequency for all listed lamps: 20 KHz to 33 KHz Specifications Power Factor: High.
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Starting method: instant start
- Input voltage: 120-277 VAC plus/minus 10%
Philips Advance® Electronic Ballast. 120 Volt. 40w. For Operating One Or Two F30t12, F30t12es, F40t12es Or F40t12 Bulbs. 85% Ballast Factor. Thermally Protected. 8 Wires: Y, Y, Bl, Bl, R, R, W, Blk. Rapid Start. Replaces R-2s40-N. Residential Grade. Mfg #913701218101
- 120 Volt
- 40w
- For Operating One Or Two F30t12, F30t12es, F40t12es Or F40t12 Bulbs
- 85% Ballast Factor
Circline 2-Bulb Fluorescent Electronic Ballast. 120 Volt. 22w And 32w. For Operating One Fc8t9 And Fc12t9. Normal Power Factor. Thermally Protected. Rapid Start. Mfg #IG230ELSX/T9
- 120 Volt
- 22w And 32w
- For Operating One Fc8t9 And Fc12t9
- Normal Power Factor
Philips Advance® Centium® Electronic Multivolt Ballast, Model #ICN2P32N. 120/277 Volt. 32w. For Operating Two F17t8, F25t8, F32t8, Fb31t8 Or Fb32t8 Bulbs Or One F40t8 Bulb. 87% Ballast Factor. Thermally Protected. 5 Wires: Blk, W, Bl, Bl, R. Instant Start. Parallel Wired. Less Than 20% Total Harmonic Distortion. Nema Qualified. Model #icn2p32n. Mfg #913710842701
- 120/277 Volt
- 32w
- For Operating Two F17t8, F25t8, F32t8, Fb31t8 Or Fb32t8 Bulbs Or One F40t8 Bulb
- 87% Ballast Factor
The Sylvania Quicktronic High Efficiency 2-lamp, 32-Watt T8, instant Start electronic ballast operates at 120-277-Volt. The ballast has a normal ballast factor. The ballast also carries a type CC rating.
- Instant start
- 2 lamp
- 32-Watt
- Electronic
- CC rated
- Normal BF
Keystone Technologys T12 Instant Start electronic ballast is designed to operate 1 or 2 T12 lamps. Featuring 120-Volt-277-Volt input and high power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, -18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEEC62.41 Cat. A
- Ballast frequency for all listed lamps: 20KHz-33KHz
- Very small plastic casing
- Will power many type of lamps
- Input: 277 VAC
- Rapid start (277 and 347V)
- High power factor greater than .9
- UL (Class P) outdoor Type 1
- End of lamp life (EOL) protection for 277V and 347V models only
- Side wire feed
High Efficiency Instant Start Electronic Ballast For Four 32 Watt T8 Lamps 347 Volt Qhe4X32T8347Islsc 347V
Sylvania QUICKTRONIC 59ISN operates OCTRON FO96 T8 lamps with maximum efficacy and provides 30% energy savings when compared to F96T12 magnetic systems. New small can enclosure on select models allows for low profile fixture design and application. New size also provides transportation, inventory and ergonomic benefits. Parallel circuitry is utilized to keep the remaining lamps lit if 1 or more should go out.
- 30% to 40% energy savings
- Virtually eliminates lamp flicker
- CSA approved
- Ideal for commercial, retail, hospitality
Keystone Technology's T9 Rapid Start electronic ballast is designed to operate 1 Circleline lamp. Featuring 120-Volt input and high-power factor design. See the document below for complete specifications including additional lamp wattages compatible with this ballast.
- Sound rated: A
- Minimum starting temperature: 0 degree F, minus 18 degree C
- Maximum case temperature: 167 degree F, 75 degree C
- Meets FCC part 18 (class B) consumer limits
- Transient protection meets ANSI/IEEE C62.41 Cat. A
- Lamp end-of-life protected
High Efficiency Instant Start Electronic Ballast For Three 32 Watt T8 Lamps 347 Volt Qhe3X32T8347Isnsc 347V