Circuit Breakers
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- 3/4 in. single pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- 3/4 in. single pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
The Eaton Cutler-Hammer 20 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use with dishwashers, waste disposals, refrigerators, freezers, washing machines, televisions and window air conditioners. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 12/2
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 60 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with spas and hot tubs. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 60 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #8-1/0 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 6/3
The Eaton Cutler-Hammer 30 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with built-in oven, range top, clothes dryer and water heater. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 10/3
The Eaton Cutler-Hammer 20 Amp 2 in. Double-Pole Type BR Replacement Circuit Breaker is UL-listed and compatible with Westinghouse, Challenger and Bryant load centers. The circuit breaker is designed for overload and short-circuit protection of your home electrical system. The breaker trips to the center position and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 12/3
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
The Eaton Cutler-Hammer 15 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use lighting fixtures. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/2
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 50 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- #10-1/0 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
The Eaton Cutler-Hammer 50 Amp 2 in. Double-Pole Type BR Replacement Circuit Breaker trips to the center position and has a maximum load of 240-Volt. The UL-listed circuit breaker is compatible with Westinghouse, Challenger and Bryant load centers. The breaker is designed for overload and short-circuit protection of your home electrical system.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 50 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 6/3
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 100 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 100 Amp
- Double pole breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #4-2/0 AWG Cu/Al at 60 degree C or 75 degree C
Eaton's residential BR circuit breakers are used in load centers, panel boards, or similar devices. Type BR Circuit Breakers are designed to protect house wires from overheating or causing a short-circuit. Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits and the effects of persistent arcing faults that may pose a risk of fire under certain conditions.
- Combination type includes all the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- FIRE-GUARD model AFCI recognizes the unique current and/or voltage signatures associated with arcing faults and efficiently interrupts the circuit to reduce fire hazards
- Branch feeder mitigates parallel arcing faults, which produce the most energy of all arcing faults, in the complete circuit including connected cords for enhanced safety
- For use in type BR load centers
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 40 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- #10-1/0 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 25 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 25 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 40 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 40 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 25 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 35 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits, including connected cords. They meet the requirements of the UL Standard for Safety, UL 1699 for devices that reduce the effects of persistent arcing faults that may pose a risk of fire under certain conditions. Arcing creates high intensity heating at the point of the arc resulting in burning particles that may over time ignite surrounding material, such as wood framing or insulation. The CHFCAF120 is a 20 Amp combination type breaker that includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets.
- Combination type includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- Branch feeder mitigates parallel arcing faults, which produce the most energy of all arcing faults, in the complete circuit including connected cords for enhanced safety
- For use in type CH load centers
- Amp: 20 Amp
- Interrupt rating-10 kAIC
- Voltage rating is 120-Volt/240-Volt
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- Standard LED indicates 1 of 7 trip codes to simplify circuit diagnostics
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer 20/20 Amp 1 in. Duplex Type BR Circuit Breaker is also known as tandem breaker. Tandem breakers are convenient for adding circuits to a full load center and are sometimes used to reduce the physical size of the load center. This a non-circuit limiting breaker. The BR tandem line of breakers is intended for replacement purposes on load centers made prior to 1968.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 20 Amp
- 1 in. plug-on circuit breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- BR duplex circuit breakers are a replacement breaker for enclosures manufactured prior to 1968 with un-notched stabs
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton CH 60 Amp 120-Volt/240-Volt 2-Pole Circuit Breaker With Trip Flag. Primary Function Of A Circuit Breaker Is To Protect The Wire From Overheating (Overload) And Fault Currents (Short Circuit). Amperage rating: 60 amp. 2-pole breaker. Trips to off position. For use in type CH load centers only. Interrupt rating - 10 kAIC. Voltage rating is 120/240-Volt. #14-2 AWG Cu/Al 60degree C or 75degree C. HACR rated. Requires two 3/4 in. spaces. Mfg #CHF260
- Primary Function Of A Circuit Breaker Is To Protect The Wire From Overheating (Overload) And Fault Currents (Short Circuit)
- Amperage rating: 60 amp
- 2-pole breaker
- Trips to off position
The Eaton Cutler-Hammer 20 Amp 3/4 in. Duplex Double-Pole Type CHT Current-Limiting Circuit Breaker is designed to protect your home's wiring from overheating or short-circuiting. The UL listed breaker has a maximum load of 240-Volt and trips to the off position. This breaker is compatible with load centers marked CHT.
- Breakers are plug-on
- Requires one 3/4 in. space
- Switching duty rated
- Heating, air conditioning and refrigeration (HACR) rated
The Eaton Cutler-Hammer 15 Amp 3/4 in. Duplex Double-Pole Type CHT Current-Limiting Circuit Breaker is designed to protect your home's wiring from overheating or short-circuiting. The UL listed breaker has a maximum load of 240-Volt and trips to the off position. This breaker is compatible with load centers marked CHT.
- Use for overload and short-circuit protection of your home electrical system
- 2 pole in the space of 1
- Current limiting
- 120/240 VAC
- Compatible with load centers marked for use with CHT breakers
- ANSI certified and CSA and UL listed
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 15 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with Eaton's line of whole house surge devices. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/4
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer 15/15 Amp 1 in. Duplex Type BR Circuit Breaker is also known as tandem breaker. Tandem breakers are convenient for adding circuits to a full load center and are sometimes used to reduce the physical size of the load center. This a non-circuit limiting breaker. The BR tandem line of breakers is intended for replacement purposes on load centers made prior to 1968.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 15 Amp
- 1 in. plug-on circuit breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- BR duplex circuit breakers are a replacement breaker for enclosures manufactured prior to 1968 with un-notched stabs
Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits, including connected cords. They meet the requirements of the UL Standard for Safety, UL 1699 for devices that reduce the effects of persistent arcing faults that may pose a risk of fire under certain conditions. Arcing creates high intensity heating at the point of the arc resulting in burning particles that may over time ignite surrounding material, such as wood framing or insulation. The CHFCAF115 is a 15 Amp combination type breaker that includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets.
- Combination type includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- Branch feeder mitigates parallel arcing faults, which produce the most energy of all arcing faults, in the complete circuit including connected cords for enhanced safety
- For use in type CH load centers
- Amp: 15 Amp
- Interrupt rating-10 kAIC
- Voltage rating is 120-Volt/240-Volt
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- Standard LED indicates 1 of 7 trip codes to simplify circuit diagnostics
The Eaton Cutler-Hammer 30 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use lighting fixtures. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Single pole 1 in. wide breaker
Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits, including connected cords. They meet the requirements of the UL Standard for Safety, UL 1699 for devices that reduce the effects of persistent arcing faults that may pose a risk of fire under certain conditions. Arcing creates high intensity heating at the point of the arc resulting in burning particles that may over time ignite surrounding material, such as wood framing or insulation. The BRN120AF is a 20 Amp combination type breaker that includes all the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets.
- Fire-guard model AFCI recognizes the unique current and/or voltage signatures associated with arcing faults and efficiently interrupts the circuit to reduce fire hazards
- Branch feeder mitigates parallel arcing faults which produce the most energy of all arcing faults in the complete circuit including connected cords for enhanced safety
- Combination type includes all the protection of the branch feeder plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- For use in type BR load centers
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturers circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position
Eaton's Classified Circuit Breakers deliver on safe installation and reliable operation. Eaton Classified replacement Circuit Breakers are available in both 3/4-inch Type CHQ and 1-inch Type CL, single- and two-pole configurations. These breakers are UL-listed and designed to be used in loadcenters made by other manufacturers.
- Eaton Classified Breakers meet or exceed relevant codes and standards and are rigorously tested and listed by UL
- Compatible with loadcenters produced by General Electric, Siemens, Murray, Square D and other manufacturers
- It is important to know that Classified Circuit Breakers are for use with panelboards rated 225 amperes, are limited to 120/40 volt applications and the available short circuit rating cannot exceed 10 kilo-amperes
- Eaton Classified Circuit Breakers are UL listed, so the original manufacturer's warranty would still be effective when you apply our technology within applicable loadcenters
Use the Eaton 100 Amp Double-Pole CH type Circuit Breaker in two 3/4 in. load center spaces. This circuit breaker trips to the off position and accommodates solid and stranded wires to be used together for installation ease and convenience. For safety, this breaker meets UL489, CSA and NEMA requirements.
- Fits into two 3/4-in. spaces for CH type load centers
- Safely trips to the off position
- Allows solid and stranded wire to be used together
- Meets UL489, CSA and NEMA standards
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton 60 Amp Double-Pole Type CH Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Eaton offers CH 3/4 in. circuit breakers with a thermal-magnetic trip curve that avoids nuisance tripping on mild overloads while reacting almost instantaneously to severe short-circuit conditions.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 60 Amp
- Double pole breaker
- Trips to off position
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- #14-2 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
- Requires two 3/4 in. spaces
Eaton's Classified Circuit Breakers deliver on safe installation and reliable operation. Eaton Classified replacement Circuit Breakers are available in both 3/4-inch Type CHQ and 1-inch Type CL, single- and two-pole configurations. These breakers are UL-listed and designed to be used in loadcenters made by other manufacturers.Eatons CL GFCI circuit breakers provide protection for people from hazards of electrical shock in areas where electricity may meet water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs, outdoor receptacles, etc.
- Eaton Classified Breakers meet or exceed relevant codes and standards and are rigorously tested and listed by UL
- Compatible with loadcenters produced by General Electric, Siemens, Murray, Square D and other manufacturers
- It is important to know that Classified Circuit Breakers are for use with panelboards rated 225 amperes, are limited to 120/40 volt applications and the available short circuit rating cannot exceed 10 kilo-amperes
- Eaton Classified Circuit Breakers are UL listed, so the original manufacturer's warranty would still be effective when you apply our technology within applicable loadcenters
Eaton's Classified Circuit Breakers deliver on safe installation and reliable operation. Eaton Classified replacement Circuit Breakers are available in both 3/4-inch Type CHQ and 1-inch Type CL, single- and two-pole configurations. These breakers are UL-listed and designed to be used in loadcenters made by other manufacturers.Eatons CL GFCI circuit breakers provide protection for people from hazards of electrical shock in areas where electricity may meet water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs, outdoor receptacles, etc.
- Eaton Classified Breakers meet or exceed relevant codes and standards and are rigorously tested and listed by UL
- Compatible with loadcenters produced by General Electric, Siemens, Murray, Square D and other manufacturers
- It is important to know that Classified Circuit Breakers are for use with panelboards rated 225 amperes, are limited to 120/40 volt applications and the available short circuit rating cannot exceed 10 kilo-amperes
- Eaton Classified Circuit Breakers are UL listed, so the original manufacturer's warranty would still be effective when you apply our technology within applicable loadcenters
Eaton's BR Ground Fault Current Interrupters (GFCIs) are 1 in. wide and provide superior safety over a standard electrical outlet in areas where electricity may meet water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution. This circuit breaker periodically runs a self-test diagnostic and complies UL 943, Fourth Edition.
- Amperage rating: 20 Amp
- Self-test GFCI
- For use in type BR load centers
- Interrupt rating-10 kAIC
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer 20/20 Amp 1 in. Duplex Type BD Circuit Breaker is also known as tandem or circuit limiting breaker. This style of breaker will only fit into load center bus stabs that are notched to accommodate the rejection clip built into the bus bar contact on the breaker. This is a code requirement that limits the number of breakers that can be installed into a load center.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 20 Amp
- Duplex 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Eaton's CH ground fault current interrupters (GFCIs) are 3/4 in. W and provide superior safety over a standard electrical outlet in areas where electricity may come into contact with water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution. This circuit breaker periodically runs a self-test diagnostic and complies UL 943, Fourth Edition.
- Amperage-20 Amp
- Self-test GFCI with trip flag
- For use in type CH load centers
- Interrupt rating-10 kaic
- Voltage rating is 120-Volt/240-Volt
- Trip indication via mechanical flag
- Flag visually confirms "Tripped" status, making it easy for the homeowner to identify
- 5 mA ground fault protection
- Periodic self-test diagnostic ensures ground fault detection and protection is functional
Eatons CL Type Combination Arc Fault Circuit Interrupter is a device that includes all the protection offered by the Branch/Feeder AFCI. Combination AFCIs can therefore mitigate the effect of low current arcs not only in the installed wiring but also in the two wire cord sets and power-supply cords connected to the outlets. CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers panel board. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. AFCIs are required in all 120-Volt, single-phase, 15 Amp and 20 Amp branch circuits supplying outlets installed in dwelling unit family rooms, dining rooms, parlors, living rooms, libraries, dens, bedrooms, sun rooms, closets, recreation rooms, hallways or similar rooms or areas shall be protected by a listed arc fault circuit interrupter, combination-type, installed to provide protection of the branch circuit.
- Used to help provide protection from fires caused by arcing faults
- Low-level arc detection through connected cords
- Breaker detects both parallel and series arcing
- Trips to the off position and can be reset safely and easily
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position