Circuit Breakers
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- 3/4 in. single pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- 3/4 in. single pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
The Eaton Cutler-Hammer 20 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use with dishwashers, waste disposals, refrigerators, freezers, washing machines, televisions and window air conditioners. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 12/2
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
The Eaton Cutler-Hammer 15 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use lighting fixtures. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/2
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
The Eaton Cutler-Hammer 30 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with built-in oven, range top, clothes dryer and water heater. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 10/3
The Eaton Cutler-Hammer 20 Amp 2 in. Double-Pole Type BR Replacement Circuit Breaker is UL-listed and compatible with Westinghouse, Challenger and Bryant load centers. The circuit breaker is designed for overload and short-circuit protection of your home electrical system. The breaker trips to the center position and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 12/3
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 50 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- #10-1/0 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 35 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 40 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 40 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 40 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- #10-1/0 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 25 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 100 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 100 Amp
- Double pole breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #4-2/0 AWG Cu/Al at 60 degree C or 75 degree C
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 60 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with spas and hot tubs. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 60 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #8-1/0 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 6/3
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 15 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with Eaton's line of whole house surge devices. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/4
Eaton's BR Ground Fault Current Interrupters (GFCIs) are 1 in. wide and provide superior safety over a standard electrical outlet in areas where electricity may meet water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution. This circuit breaker periodically runs a self-test diagnostic and complies UL 943, Fourth Edition.
- Amperage rating: 20 Amp
- Self-test GFCI
- For use in type BR load centers
- Interrupt rating-10 kAIC
The Eaton Cutler-Hammer 20 Amp 3/4 in. Duplex Double-Pole Type CHT Current-Limiting Circuit Breaker is designed to protect your home's wiring from overheating or short-circuiting. The UL listed breaker has a maximum load of 240-Volt and trips to the off position. This breaker is compatible with load centers marked CHT.
- Breakers are plug-on
- Requires one 3/4 in. space
- Switching duty rated
- Heating, air conditioning and refrigeration (HACR) rated
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 25 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 25 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
Eaton's CH ground fault current interrupters (GFCIs) are 3/4 in. W and provide superior safety over a standard electrical outlet in areas where electricity may come into contact with water. GFCIs are required in any application near water such as kitchen countertops, bathrooms, swimming pools, hot tubs and outdoor receptacles. They immediately break the circuit when electrical current leakage is detected, reducing the risk of shock and electrocution. This circuit breaker periodically runs a self-test diagnostic and complies UL 943, Fourth Edition.
- Amperage-20 Amp
- Self-test GFCI with trip flag
- For use in type CH load centers
- Interrupt rating-10 kaic
- Voltage rating is 120-Volt/240-Volt
- Trip indication via mechanical flag
- Flag visually confirms "Tripped" status, making it easy for the homeowner to identify
- 5 mA ground fault protection
- Periodic self-test diagnostic ensures ground fault detection and protection is functional