Distribution & Breakers
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- 3/4 in. single pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- 3/4 in. single pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position
With a focus on improved safety, revolutionary design and ease of installation, Leviton takes the load center into the 21st century. Leviton offers a full line of accessories to meet every need when installing the Leviton Load Center. Locking devices, lugs, ground and neutral bar kits, conduit hubs, sealing rings and more are all available to ensure an accurate and quick installation.
- Designed for use with Leviton load center panels
- Cover empty branch breaker positions
- Sleek and appealing design covers removed dead front twist-outs
- 10-year limited warranty
- Compatible with Leviton brand load center electrical panels
The Bussmann series BP-FRN-R-30 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 8 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 30 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
- Separate overload and short-circuit elements provide time delay for sizing as close as 125% of motor FLA while delivering excellent short-circuit protection
Bussmann 3 Amp Fast Acting Blade Fuse. Bussmann Atc Blade-Type Fuse. 32 Volt. 3 Amp. Fast Acting. For HVAC Control Boards, Automotive And Small Appliance Circuits. Package Of 5. Mfg #BP/ATC-3-RP. Mfg #BP/ATC-3-RP
- Bussmann Atc Blade-Type Fuse
- 32 Volt
- 3 Amp
- Fast Acting
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
The Bussmann series BP-FRN-R-20 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 8 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 20 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Leviton Circuit Breakers provide overload and short-circuit protection and feature an all plug-on design. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired without circuit breakers installed. Branch circuit breakers can be easily plugged on at final installation. They also feature color indicators in the handle to easily see operational status at-a-glance. For applications up to 60 Amp when using copper wire or 50 Amp when using aluminum wire.
- Simple - features an all plug-on design - no wiring to the circuit breaker
- Intuitive - color indicators in the handle to easily see operational status at-a-glance
- Approachable - contemporary aesthetic and rocker style handle are more user friendly
- 10 kA short-circuit rating
- Compatible with Leviton brand load center electrical panels
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- Single pole, 15 Amp 120-Volt type QP interchangeable circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
The Bussmann series BP-FRN-R-40 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 40 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series BP-FRN-R-35 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 35 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream FUSETRON fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Leviton Circuit Breakers provide overload and short-circuit protection and feature an all plug-on design. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired without circuit breakers installed. Branch circuit breakers can be easily plugged on at final installation. They also feature color indicators in the handle to easily see operational status at-a-glance. For applications up to 60 Amp when using copper wire or 50 Amp when using aluminum wire.
- Simple - features an all plug-on design - no wiring to the circuit breaker
- Intuitive - color indicators in the handle to easily see operational status at-a-glance
- Approachable - contemporary aesthetic and rocker style handle are more user friendly
- 10 kA short-circuit rating
- Compatible with Leviton brand load center electrical panels
Bussmann 5 Amp Fast Acting Blade Fuse. Bussmann Atc Blade-Type Fuse. 32 Volt. 5 Amp. Fast Acting. For HVAC Control Boards, Automotive And Small Appliance Circuits. Pkg Of 5. Mfg #BP/ATC-5-RP. Mfg #BP/ATC-5-RP
- Bussmann Atc Blade-Type Fuse
- 32 Volt
- 5 Amp
- Fast Acting
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- Single pole, 20 Amp 120-Volt type QP interchangeable circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
The Bussmann series BP-FRN-R-60 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 60 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series BP-FRN-R-15 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 8 seconds (minimum) at 500% of rated current. For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 15 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream FUSETRON fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series BP-FRN-R-50 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 50 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream Fusetron fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
The Bussmann series BP-FRN-R-25 is an energy-efficient, dual-element, current limiting, time-delay Class RK5 fuse pack (2-pack) from the FUSETRON line. Its design offers optimal time-delay protection for equipment like power panelboards, motor control centers, and safety switches. Dual-element fuses separate overload and short-circuit protection, allowing inrush currents without blowing. This time-delay feature supports temporary overloads common during motor or transformer startups, reducing unnecessary fuse replacements. Time-delay - 10 seconds (minimum) at 500% of rated current.For enhanced protection, consider upgrading to Bussmann Low-Peak LPN-RK fuses. These fuse cartridges are UL- and CSA Listed for safety.
- Used in power panel boards, motor control centers, combination starters and machinery disconnects
- Operating maximum of 25 Amps and 250 Volts
- UL- and CSA Listed
- Closer sizing allows for smaller fuses and less costly switches
- Helps protect motors against burnout from overloads and single-phasing on three-phase systems
- Simplifies and improves blackout prevention (selective coordination)
- 2:1 selective coordination amp ratio (within the Bussmann series RK5 fuse family) prevents overcurrent events from opening upstream FUSETRON fuses
- Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance short-circuit and overload protection
- The overload element provides protection against low level overcurrent of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Leviton Circuit Breakers provide overload and short-circuit protection and feature an all plug-on design. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired without circuit breakers installed. Branch circuit breakers can be easily plugged on at final installation. They also feature color indicators in the handle to easily see operational status at-a-glance. For applications up to 60 Amp when using copper wire or 50 Amp when using aluminum wire.
- Simple - features an all plug-on design - no wiring to the circuit breaker
- Intuitive - color indicators in the handle to easily see operational status at-a-glance
- Approachable - contemporary aesthetic and rocker style handle are more user friendly
- 10 kA short-circuit rating
- Compatible with Leviton brand load center electrical panels
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position
Siemens replacement QO breakers are UL listed for use in Square D QO brand load centers and are ideal for replacement of existing breakers or if expansion circuits are required. These 3/4 in. breakers snap on to the QO type bussing. All QD breakers are supplied with load side connectors suitable for 60/75C wire and are calibrated for 40C maximum ambient applications. Siemens QD circuit breakers are available in 15 to 60 Amp, single and double pole configurations and are rated at 120/240-Volt AC.
- Square D QO compatible - 3/4 in. plug-in format
- UL classified for use in place of Square D type QO circuit breakers in Square D load centers
- Economical alternative for replacement or in new construction
- HACR and SWD rated
- Developed and tested to UL 489; assuring performance equal to or exceeding UL requirements
- Designed for residential/commercial applications
Leviton is proud to bring the Load Center into the 21st century with a focus on improved safety and ease of installation. Thanks to its revolutionary design, all hot and neutral wires terminate at custom lugs in the panel, rather than at the circuit breaker*, which allows the entire panel to be wired at rough-in. Branch circuit breakers are simply plugged-in at final installation, increasing jobsite efficiency. Leviton Dual Function branch circuit breakers feature an intuitive color indicator in the handle, which designates operational status at-a-glance, as well as a line-side powered LED to indicate when a fault has occured, and what type of fault - arc, or ground.
- EASY - The Load Center can be wired without any breakers present
- SAFE - Reset lockout technology prevents use of compromised unit
- INTUITIVE - LEDs communicate trip condition and type of fault
- COMFORTABLE - Rocker-style switches require less force to operate
- Compatible with Leviton brand load center electrical panels
Leviton Circuit Breakers provide overload and short-circuit protection and feature an all plug-on design. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired without circuit breakers installed. Branch circuit breakers can be easily plugged on at final installation. They also feature color indicators in the handle to easily see operational status at-a-glance. For applications up to 60 Amp when using copper wire or 50 Amp when using aluminum wire.
- Simple - features an all plug-on design - no wiring to the circuit breaker
- Intuitive - color indicators in the handle to easily see operational status at-a-glance
- Approachable - contemporary aesthetic and rocker style handle are more user friendly
- 10 kA short-circuit rating
- Compatible with Leviton brand load center electrical panels
The Square D by Schneider Electric Homeline 30 Amp One-Pole Circuit Breaker is used for overload and short-circuit protection of your electrical system. This breaker is compatible with Homeline load centers and CSED devices. The ANSI-certified and UL-Listed unit is rated for 120/240 VAC and 10,000 AIR. Homeline circuit breakers are built with the same Square D brand quality you have come to expect at a price that makes them the best value in their class. Homeline circuit breakers are the best in class. Designed exclusively for the residential market, Homeline products offer everything you need to distribute electricity throughout your home.
- Square D Homeline 30 Amp one-pole circuit breaker
- Plug-on design, easy to install
- Compatible with Square D Homeline breaker boxes and CSED devices
- This breaker needs 1 space in a breaker box for installation
- 120/240-Volt AC
- 10,000 AIR
- Limited lifetime warranty
The Square D by Schneider Electric QO 15 Amp One-Pole Circuit Breaker is intended for overload and short-circuit protection of your electrical system. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. All QO circuit breakers are equipped with the exclusive Visi-Trip indicator. When a QO Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between in. OFF in. and in. ON in. and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 42 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection.
- Square D QO 15 Amp one-pole circuit breaker
- Plug-on design, easy to install
- Compatible with Square D QO breaker boxes, CSED's and NQOD panel boards
- This breaker needs 1 space in a breaker box for installation
- 120/240-Volt AC
- 10,000 AIR
- ANSI certified and UL Listed
- Limited lifetime warranty
Leviton is proud to bring the Load Center into the 21st century with a focus on improved safety and ease of installation. Thanks to its revolutionary design, all hot and neutral wires terminate at custom lugs in the panel, rather than at the circuit breaker*, which allows the entire panel to be wired at rough-in. Branch circuit breakers are simply plugged-in at final installation, increasing jobsite efficiency. Leviton Hydraulic Magnetic standard branch circuit breakers are designed to perform effectively even in the harshest environments, and feature an intuitive color indicator in the handle, which designates operational status at-a-glance.
- EASY - The Load Center can be wired without any breakers present
- HYDRAULIC MAGNETIC - Operates as intended from -40°F to 185°F
- COMFORTABLE - Rocker-style switches require less force to operate
- Compatible with Leviton brand load center electrical panels
Siemens PN Series Load Centers - a high quality and feature-rich line of load center products designed to meet applications for virtually every need. The PN Series load center provides maximum flexibility in combination with labor saving features to aid the contractor while installing the product. PN Series load centers accept the plug-on neutral breakers, patented insta-wire neutral/ground system, convertibility, copper bussing and mounting tabs on the trim - these features were specifically engineered to decrease installation time and increase flexibility.
- Features siemens plug-on neutral, for simple quick installation, that is spacious with over 4 in. of wire bending space, and a secure reliable installation method
- PN Series plug-on neutral load center includes 2 factory installed ground bars
- Single phase load center
- Tin plated copper bus
- NEMA Type 1 enclosure
- Grey trim
- Interrupt rating: 22000 AIC
- UL Listed
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- 2-pole, 30 Amp, 120-Volt/240-Volt type QP interchangeable circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
Reliable product from the technology leader. Technology enabling reliability. When it comes to ready availability, easy installation and fewer callbacks, you need a manufacturer you can trust. Our products and systems are engineered to take on the most demanding conditions, always service and maintenance network, complete support is always there.
- 1-1/2 in. type RX conduit hub is intended for use with an electric center and conduit, the hub is ANSI certified and CSA and UL listed for use with Siemens products
- Product is type RX hubs that is 1 in. and 1/2 in.
- Product is compatible with Siemens products
- Product is ANSI certified and CSA and UL listed
The Square D by Schneider Electric QO 20 Amp Two-Pole Circuit Breaker is intended for overload and short-circuit protection of your electrical system. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. All QO circuit breakers are equipped with the exclusive Visi-Trip indicator. When a QO Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between in OFF and in ON and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 42 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection.
- Square D QO 20 Amp two-pole circuit breaker
- Plug-on design, easy to install
- Compatible with Square D QO breaker boxes, CSED's and NQOD panel boards
- This breaker needs 2 spaces in a breaker box for installation
- 120/240-Volt AC
- 10,000 AIR
- Limited lifetime warranty
The Square D by Schneider Electric QO 200 Amp Outdoor Circuit Breaker Enclosure includes a two-pole QOM2 frame sizes circuit breakers 100-225 amp capacity for use as an exterior disconnect. This breaker box is suitable for use as service entrance equipment for compliance up to 2017 NEC code, and is rated Type-3R for outdoor use. This enclosure accepts a B-Hub for top feed applications (sold separately). For non-service entrance equipment applications, ground bar PKOGTA-2 is included.
- Square D QOM2 200 Amp outdoor circuit breaker enclosure with QOM2200VH circuit breaker included
- Includes a PKOGTA-2 ground bar kit, B-hubs not included
- Not for use with single-pole QO breakers
- Includes (1) Square D QOM2200VH 200 Amp circuit breaker, 22 kA interruption rating
- Type-3R enclosure for outdoor use
- 1-phase, 200 Amp, 120/240-Volt AC rated
- 2-1/2 in. maximum B-type hub on the top and a 2 in. maximum knockout on the bottom
- Surface mountable for easy installation
- ANSI certified and UL Listed
- For installation as entrance device to comply with code up to 2017 NEC Code
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 50 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- #10-1/0 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQC style breaker has a common trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQC circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 2-pole 30 Amp
- Number of poles - 4
- Trip type - common
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
This is a main lug kit for Type CH loadcenters. It is for a 125 Amp panel. Eaton is a trusted name in electrical products for over 175-years.
- Used in Type CH convertible type loadcenters
- Maximum amperage rating for Type CH convertible panels is 125 Amp
- Can be used with the CH22N125C and CH22N125R panels
- Wire size is #101/0
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Littelfuse FLNR series fuses have been the superior UL Class RK5 dual-element time-delay fuses and are the most widely used class of fuses. FLNR series fuses provide excellent protection for all types of circuits especially those containing motors. However, users and specifiers should consider the significant benefits offered by Indicator fuses.
- 200,000 A.I.R. - reliable interruption of all over currents up to 200,000 Amp
- Faster acting short circuit protection than any non-current limiting mechanical protective device
- Accurate and reliable - automated, precision manufactured and assembled parts ensure accurate, consistent response to overloads and short circuits
- Sold in packs of 10
The Square D by Schneider Electric QO 20 Amp One-Pole Circuit Breaker is intended for overload and short-circuit protection of your electrical system. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. All QO circuit breakers are equipped with the exclusive Visi-Trip indicator. When a QO Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between in. OFF in. and in. ON in. and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 42 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection.
- QO 20 Amp one-pole circuit breaker
- QO 20 Amp one-pole circuit breaker is designed for overload and over-current protection of your electrical system through its thermal-magnetic tripping mechanism
- Breaker offers a visi-trip indicator to let you easily identify which circuit is out in the load center
- Use for overload and over-current protection of your electrical system
- Thermal-magnetic tripping mechanism
- Compatible with QO load centers, CSED devices and NQOD panel boards
- 10,000 AIR
- 120/240 VAC
- ANSI certified and UL Listed
Leviton Circuit Breakers provide overload and short-circuit protection and feature an all plug-on design. All hot and neutral wires terminate at custom lugs in the panel, not at the circuit breaker, so the entire panel can be wired without circuit breakers installed. Branch circuit breakers can be easily plugged on at final installation. They also feature color indicators in the handle to easily see operational status at-a-glance. For applications up to 60 Amp when using copper wire or 50 Amp when using aluminum wire.
- Simple - features an all plug-on design - no wiring to the circuit breaker
- Intuitive - color indicators in the handle to easily see operational status at-a-glance
- Approachable - contemporary aesthetic and rocker style handle are more user friendly
- 10 kA short-circuit rating
- Compatible with Leviton brand load center electrical panels
Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits, including connected cords. They meet the requirements of the UL Standard for Safety, UL 1699 for devices that reduce the effects of persistent arcing faults that may pose a risk of fire under certain conditions. Arcing creates high intensity heating at the point of the arc resulting in burning particles that may over time ignite surrounding material, such as wood framing or insulation. The CHFCAF115 is a 15 Amp combination type breaker that includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets.
- Combination type includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- Branch feeder mitigates parallel arcing faults, which produce the most energy of all arcing faults, in the complete circuit including connected cords for enhanced safety
- For use in type CH load centers
- Amp: 15 Amp
- Interrupt rating-10 kAIC
- Voltage rating is 120-Volt/240-Volt
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- Standard LED indicates 1 of 7 trip codes to simplify circuit diagnostics
Leviton is proud to bring the Load Center into the 21st century with a focus on improved safety and ease of installation. Thanks to its revolutionary design, all hot and neutral wires terminate at custom lugs in the panel, rather than at the circuit breaker*, which allows the entire panel to be wired at rough-in. Branch circuit breakers are simply plugged-in at final installation, increasing jobsite efficiency. Leviton AFCI branch circuit breakers feature an intuitive color indicator in the handle, which designates operational status at-a-glance, as well as a line-side powered LED to indicate when a fault has occured.
- EASY - The Load Center can be wired without any breakers present
- SAFE - Reset lockout technology prevents use of compromised unit
- INTUITIVE - LEDs communicate trip condition and type of fault
- COMFORTABLE - Rocker-style switches require less force to operate
- Compatible with Leviton brand load center electrical panels
This is a 30 Amp to 60 Amp Class R Fuse reducer. This reducers allows for fitting a 30 Amp fuse in a 60 Amp block or disconnect switch. Fuse reducers install on fuse ferrules or blades.
- Reducers fit into most panels and switches, including dead-front type
- Strong contact is maintained both mechanically and electrically
- RoHS compliant
- 250-Volt
The off-center conduit threaded opening of the Square D by Schneider Electric 2 in. Bolt-On Hub, along with its elongated mounting holes, reduces the need for costly conduit offsets and bends while allowing for easy and quick adjustments. The Square D by Schneider Electric 2 in. Hub is for use in Square D load centers, CSED devices and safety switches. This hub is a Type B size and is UL and CSA safety listed.
- For use in Square D load centers, CSED devices and safety switches
- Can be used for outdoor load centers and safety switches
- UL and CSA listed
- Type B size
- ANSI certified
The Square D by Schneider Electric QO 25 Amp Two-Pole Circuit Breaker is intended for overload and short-circuit protection of your electrical system and is compatible with Square D QO load centers, CSED devices, and NQOD. The ANSI-certified and UL-listed unit is rated for 120/240 VAC and 10,000 AIR. All QO circuit breakers are equipped with the exclusive Visi-Trip indicator. When a QO Visi-Trip circuit breaker trips, the handle snaps to a midpoint position between "OFF" and "ON" and a highly visible, red indicator easily identifies the tripped breaker. This enables you to easily distinguish which breaker has tripped in a load center that may contain up to 42 different circuit breakers. QO circuit breakers have features no other manufacturer can offer. They come in many different sizes and can meet the needs of virtually every function in your home or business. These types of quality, industry exclusive products keep the Square D brand ahead of the competition and are builders' and electrical contractors' first choice in electrical protection.
- Square D QO 25 Amp two-pole circuit breaker
- Plug-on design, easy to install
- Compatible with Square D QO breaker boxes, CSED's and NQOD panel boards with 2 spaces
- For installation in 120/240-Volt AC systems
- 10,000 AIR
- Limited lifetime warranty
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your home's electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- 2-pole, 50 Amp, 240-Volt type QP circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic
The Eaton Cutler-Hammer 20 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use with dishwashers, waste disposals, refrigerators, freezers, washing machines, televisions and window air conditioners. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 12/2
Siemens offers a wide array of thermal-magnetic circuit breakers that are the key element for overload and short-circuit protection of your homes electrical system. To provide additional protection Siemens offers circuit breakers to protect against severe electrical shock or electrocution, mitigate the risk of electrical fires and protect against damaging surges and Voltage spikes. Circuit breakers are intended for switching and protection of your home's wiring from high temperatures caused by excess current higher than the rating of the wire. While thermal-magnetic circuit breakers are the key element for overload and short-circuit protection of your electrical system, there are potentially dangerous conditions that do not involve over current.
- 2-pole, 25 Amp, 240-Volt type QP circuit breaker
- 10,000 AIC interrupting rating
- Siemens type QP circuit breakers provide easy plug-in connections in Siemens enclosures and the time saving insta-wire feature
- Compatible with Siemens PL and ES series load centers
- Use for overload and short-circuit protection of your electrical system
- Thermal-magnetic