Electrical
An air conditioning disconnect (ACD) is a disconnect located between a loadcenter (distribution panel) and air conditioner. Eaton's ACD product line provides an installer or repair personnel with a visible disconnecting means when performing maintenance. ACDs are also known as disconnects, pullouts or air conditioning switches.The most widely used application for ACDs is for residential and light commercial air conditioning units. An ACD is installed outdoors, in visible proximity to the air conditioner condensing unit. Metallic enclosures are galvanized steel and are installed in various locations. Nonmetallic enclosures are a plastic (polycarbonate) enclosure commonly used in coastal or salt-water areas.
- ON/OFF control provided by a pullout handle
- Pullout handle can be conveniently stored in the compartment in the OFF position, helping to prevent the handle from being misplaced
- Protective shield cannot be removed until the pullout handle is removed, disconnecting the power
- Enclosure is rated NEMA 3R for outdoor use and material is galvanized steel
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- 3/4 in. single pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
The Eaton Cutler-Hammer 20 Amp 2 in. Double-Pole Type BR Replacement Circuit Breaker is UL-listed and compatible with Westinghouse, Challenger and Bryant load centers. The circuit breaker is designed for overload and short-circuit protection of your home electrical system. The breaker trips to the center position and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 12/3
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- 3/4 in. single pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
The Eaton Cutler-Hammer 20 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use with dishwashers, waste disposals, refrigerators, freezers, washing machines, televisions and window air conditioners. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 12/2
The Eaton Cutler-Hammer 15 Amp 1 in. Single-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Single pole breaker applications include use lighting fixtures. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Single pole 1 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/2
Our homes are filled with sensitive electronics. These devices are easily damaged by common power surges in your electrical, telephone and cable lines. It only takes a lightning storm near your home to create a high-energy electrical surge that can enter your house and destroy your appliances, TVs, stereo equipment and almost all other modern electrical products. The Eaton surge products are designed to provide protection at the point of entrance to the home. Protection at this location can reduce surges entering the home to an acceptable level for your home electronics and appliances.
- Does not protect against direct lighting strikes
- Externally mounted making it universal - compatible with any manufacturer's load center
- Product should be connected on the load side of the load center main service disconnect through a dedicated circuit breaker
- Product is recommended to use a 2-pole 50 Amp circuit breaker, sold separately
- Eaton's complete home surge protection type 2 devices (CHSPT2 Series) protect your home electronics from the damaging effects of electrical surges
- Provide premium surge protection for AC power and cable at the point of entrance to the home
- CHSPT2 family of products require a dedicated 2-pole 50 Amp thermal magnetic breaker
- Externally mounted making it universal - compatible with any manufacturer's load center or breaker box
The Eaton Cutler-Hammer Type-BR Circuit Breaker Filler Plates allows you to cover unused spaces in a load center. This ensures that the live space is closed off. It is UL safety listed.
- Covers unused spaces in a load center
- For use with cutler-hammer type-BR load centers
- 1 in. plate for branch breaker slots
- UL listings
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
An air conditioning disconnect (ACD) is a disconnect located between a loadcenter (distribution panel) and air conditioner. Eaton’s ACD product line provides an installer or repair personnel with a visible disconnecting means when performing maintenance. ACDs are also known as disconnects, pullouts or air conditioning switches. The most widely used application for ACDs is for residential and light commercial air conditioning units. An ACD is installed outdoors, in visible proximity to the air conditioner condensing unit. Metallic enclosures are galvanized steel and are installed in various locations. Nonmetallic enclosures are a plastic (polycarbonate) enclosure commonly used in coastal or salt-water areas.
- ON/OFF control provided by a pullout handle
- Pullout handle can be conveniently stored in the compartment in the OFF position, helping to prevent the handle from being misplaced
- Protective shield cannot be removed until the pullout handle is removed, disconnecting the power
- Enclosure is rated NEMA 3R for outdoor use and material is galvanized steel
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton's residential BR circuit breakers are used in load centers, panel boards, or similar devices. Type BR Circuit Breakers are designed to protect house wires from overheating or causing a short-circuit. Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits and the effects of persistent arcing faults that may pose a risk of fire under certain conditions.
- Combination type includes all the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- FIRE-GUARD model AFCI recognizes the unique current and/or voltage signatures associated with arcing faults and efficiently interrupts the circuit to reduce fire hazards
- Branch feeder mitigates parallel arcing faults, which produce the most energy of all arcing faults, in the complete circuit including connected cords for enhanced safety
- For use in type BR load centers
The Eaton Cutler-Hammer 60 Amp 120/240-Volt 14,400-Watt Fused Air Conditioning Disconnect is ANSI certified and CSA and UL listed. The unit has a metallic enclosure and is rated for outdoor use. The fused disconnect is compatible with class H fuses and is intended to disconnect power from an air-conditioning unit.
- Use to disconnect power from an air-conditioning unit
- NEMA 3R
- Single phase
- ON/OFF control provided by a pullout handle
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 100 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 100 Amp
- Double pole breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #4-2/0 AWG Cu/Al at 60 degree C or 75 degree C
The Eaton Cutler-Hammer 30 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with built-in oven, range top, clothes dryer and water heater. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 30 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 10/3
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 50 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- #10-1/0 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits, including connected cords. They meet the requirements of the UL Standard for Safety, UL 1699 for devices that reduce the effects of persistent arcing faults that may pose a risk of fire under certain conditions. Arcing creates high intensity heating at the point of the arc resulting in burning particles that may over time ignite surrounding material, such as wood framing or insulation. The BRN120AF is a 20 Amp combination type breaker that includes all the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets.
- Fire-guard model AFCI recognizes the unique current and/or voltage signatures associated with arcing faults and efficiently interrupts the circuit to reduce fire hazards
- Branch feeder mitigates parallel arcing faults which produce the most energy of all arcing faults in the complete circuit including connected cords for enhanced safety
- Combination type includes all the protection of the branch feeder plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- For use in type BR load centers
An Air Conditioning (AC) Disconnect provides an installer or repair personnel with a visible disconnecting means while performing maintenance on an air conditioning unit. The Eaton 30 Amp 120/240-Volt AC Disconnect is ANSI certified and UL listed. The unit is approved for outdoor use and features a metallic enclosure. This safety switch is designed to disconnect power from an air-conditioning unit and is rated for up to 240-Volt.
- Type: fused pullout
- Amperage rating: 30 Amp
- Color: ANSI 61 gray
- Enclosure: NEMA 3R
- Enclosure material: galvanized steel
- Horsepower: 2 HP at 120-Volt, 3 HP at 240-Volt
- Interrupt rating: 10 kAIC
- Wire size: #14-3 AWG Cu/Al
- Fuses are sold separately
The Eaton Cutler-Hammer 20 Amp 3/4 in. Duplex Double-Pole Type CHT Current-Limiting Circuit Breaker is designed to protect your home's wiring from overheating or short-circuiting. The UL listed breaker has a maximum load of 240-Volt and trips to the off position. This breaker is compatible with load centers marked CHT.
- Breakers are plug-on
- Requires one 3/4 in. space
- Switching duty rated
- Heating, air conditioning and refrigeration (HACR) rated
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 60 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with spas and hot tubs. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 60 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #8-1/0 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 6/3
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 20 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
The Eaton 10-Terminal Grounding Bar Kit is suitable for use with type BR load centers or type CH load centers. Ground bars are required in all panels (main service panels include ground and neutral). To be sure you are selecting the correct ground bar, divide the number of circuits in the panel by 2 and pick the closest numbered ground bar. For example, a 20 circuit panel would require a GBK10P. The kit includes a 10-terminal ground bar and one 2/0 lug.
- For use as a grounding bar in a load center
- Suitable for use with type BR load centers or type CH load centers
- 10 terminals
- One 2/0 lug
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 25 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 25 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 25 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer 15/15 Amp 1 in. Duplex Type BR Circuit Breaker is also known as tandem breaker. Tandem breakers are convenient for adding circuits to a full load center and are sometimes used to reduce the physical size of the load center. This a non-circuit limiting breaker. The BR tandem line of breakers is intended for replacement purposes on load centers made prior to 1968.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 15 Amp
- 1 in. plug-on circuit breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- BR duplex circuit breakers are a replacement breaker for enclosures manufactured prior to 1968 with un-notched stabs
The Eaton Cutler-Hammer 15 Amp 3/4 in. Duplex Double-Pole Type CHT Current-Limiting Circuit Breaker is designed to protect your home's wiring from overheating or short-circuiting. The UL listed breaker has a maximum load of 240-Volt and trips to the off position. This breaker is compatible with load centers marked CHT.
- Use for overload and short-circuit protection of your home electrical system
- 2 pole in the space of 1
- Current limiting
- 120/240 VAC
- Compatible with load centers marked for use with CHT breakers
- ANSI certified and CSA and UL listed
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Eaton's Arc Fault Circuit Interrupters (AFCIs) use advanced electronic technology to reduce fire hazards in electrical circuits, including connected cords. They meet the requirements of the UL Standard for Safety, UL 1699 for devices that reduce the effects of persistent arcing faults that may pose a risk of fire under certain conditions. Arcing creates high intensity heating at the point of the arc resulting in burning particles that may over time ignite surrounding material, such as wood framing or insulation. The CHFCAF115 is a 15 Amp combination type breaker that includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets.
- Combination type includes all of the protection of the branch feeder, plus it directly detects persistent low current arcing faults down to 5 Amp to efficiently protect against fire hazards in the cords connected to outlets
- Branch feeder mitigates parallel arcing faults, which produce the most energy of all arcing faults, in the complete circuit including connected cords for enhanced safety
- For use in type CH load centers
- Amp: 15 Amp
- Interrupt rating-10 kAIC
- Voltage rating is 120-Volt/240-Volt
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- Standard LED indicates 1 of 7 trip codes to simplify circuit diagnostics
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 40 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- #10-1/0 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturers circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Our homes are filled with sensitive electronics. These devices are easily damaged by common power surges in your electrical, telephone and cable lines. It only takes a lightning storm near your home to create a high-energy electrical surge that can enter your house and destroy your appliances, TVs, stereo equipment and almost all other modern electrical products. The Eaton surge products are designed to provide protection at the point of entrance to the home. Protection at this location can reduce surges entering the home to an acceptable level for your home electronics and appliances.
- Does not protect against direct lighting strikes
- Externally mounted making it universal - compatible with any manufacturer's load center
- Product should be connected on the load side of the load center main service disconnect through a dedicated circuit breaker
- NEMA 4 enclosure for either indoor or outdoor use
- Eaton's complete home surge protection type 2 devices (CHSPT2 Series) protect your home electronics from the damaging effects of electrical surges, they provide premium surge protection for AC power and cable at the point of entrance to the home, protection at this location can reduce surges entering the home to an acceptable level for your home electronics and appliances
- Recommended to use a 2-pole 15 Amp circuit breaker, sold separately
Eaton CH 60 Amp 120-Volt/240-Volt 2-Pole Circuit Breaker With Trip Flag. Primary Function Of A Circuit Breaker Is To Protect The Wire From Overheating (Overload) And Fault Currents (Short Circuit). Amperage rating: 60 amp. 2-pole breaker. Trips to off position. For use in type CH load centers only. Interrupt rating - 10 kAIC. Voltage rating is 120/240-Volt. #14-2 AWG Cu/Al 60degree C or 75degree C. HACR rated. Requires two 3/4 in. spaces. Mfg #CHF260
- Primary Function Of A Circuit Breaker Is To Protect The Wire From Overheating (Overload) And Fault Currents (Short Circuit)
- Amperage rating: 60 amp
- 2-pole breaker
- Trips to off position
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 15 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. Double pole breaker applications include use with Eaton's line of whole house surge devices. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 15 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 14/4
The Eaton Cutler-Hammer 50 Amp 2 in. Double-Pole Type BR Replacement Circuit Breaker trips to the center position and has a maximum load of 240-Volt. The UL-listed circuit breaker is compatible with Westinghouse, Challenger and Bryant load centers. The breaker is designed for overload and short-circuit protection of your home electrical system.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 50 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- Gauge/number of wires with ground - 6/3
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer 20/20 Amp 1 in. Duplex Type BR Circuit Breaker is also known as tandem breaker. Tandem breakers are convenient for adding circuits to a full load center and are sometimes used to reduce the physical size of the load center. This a non-circuit limiting breaker. The BR tandem line of breakers is intended for replacement purposes on load centers made prior to 1968.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (2) 20 Amp
- 1 in. plug-on circuit breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
- BR duplex circuit breakers are a replacement breaker for enclosures manufactured prior to 1968 with un-notched stabs
Eaton has enhanced its premium Type CH residential circuit breakers, making the best even better. In addition to the industry exclusive "Trip to OFF" and simple 1-Step Reset feature, Eaton has added a trip flag to visibly indicate breaker status. Along with Tri-Drive screws and new markings that highlight ratings and the Eaton brand.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 35 Amp
- Double pole breaker
- Flag visually confirms tripped status, making it easy for the homeowner to identify
- For use in type CH load centers only
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- (1) #14-8, (2) #14-10 AWG Cu/Al 60 degree C or 75 degree C
- HACR rated
Eaton's Type CL circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CL Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers load center. These breakers have been tested extensively in numerous GE, Square D and Siemens, Murray Thomas and Betts and Crouse-Hinds panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying one manufacturer's circuit breaker versus multiple manufacturers
- CL breakers are available in 1 and 2-pole configurations
- 1-pole requires 1 in. space, 2-pole requires 2 in. space
- Trips to the off position
- Solid and stranded wire can be used together
- Classified arc fault and ground fault breakers are also available
- 15-year warranty
Ground bars are required in all panels (main service panels include ground and neutral). To be sure you are selecting the correct ground bar, divide the number of circuits in the panel by 2 and pick the closest numbered ground bar. For example, a 20-circuit panel would require a GBK10P. Eaton is a trusted name in electrical products for over 175-years.
- Distance between mounting holes is 1-3/4 in.
- Number of terminals: 21
- Size: 3/4 in.
- Used with: CH and BR loadcenters
- Includes: 1-2/0 lug
Specially designed for easy installation, Eaton's BR load centers house the branch circuit breakers and the wiring required to distribute power to individual circuits. This panel is a main lug panel which is used as sub-panel to add circuits to an existing main breaker panel. Sub panels are often used in a garage, home addition, barn or storage shed and/or workshop. The branch breakers protect the wires leading to individual electrical loads such as fixtures and outlets. The BR816L125RP is a 125 Amp outdoor main lug with 8-spaces and 16-circuits.
- Amperage rating: 125 Amp
- Bus material: aluminum
- Rated NEMA 3R for outdoor use
- Interrupt rating: 10 kAIC
- Mounting: combination
- Number of circuits: 16
- Number of spaces: 8
- Phase: single-phase
- Voltage rating: 120/240-Volt
- Wire size: #14-1/0 AWG Cu/Al at 60 degree C or 75 degree C
- Tangential center knockout easier installation for conduit applications
- Steel back pan provides solid and reliable breaker mounting single piece design for stability and durability
- Single keyhole mounting - one keyhole at the top provides easier mounting and leveling
- Drywall marking on enclosure - indicates proper mounting depth for flush applications
- Used with: type BR breakers
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position
Eaton's Cutler-Hammer Type CH Load centers (also known as a breaker box) include a 1-piece copper bus. This absence of bolted connections virtually eliminates the chance of hot spots or faults, ensuring a longer product life. Our standard 14-3/8 in. W enclosures fit snugly between wall studs. A variety of knockouts allows for more wiring configurations, while predrilled mounting holes provide easy installation of additional ground bars, if desired. Type CH Load centers have a lifetime warranty and accept Cutler-Hammer Type CH (3/4 in.) breakers.
- 42-space
- 200 Amp
- Cover included
- Lifetime warranty
Eaton provides product and service solutions for new residential construction for single-family and multi-family homes, as well as upgrades and replacements for existing homes. The Eaton Cutler-Hammer 40 Amp Double-Pole Type BR Replacement Circuit Breaker is designed to protect house wires from overheating or causing a short-circuit. The UL-listed breaker is compatible with Westinghouse, Challenger and Bryant load centers and has a maximum load of 240-Volt.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage rating: 40 Amp
- Double pole 2 in. wide breaker
- Trips to center position - must turn off then turn back on
- For use in type BR load centers
- Type BR breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger and Bryant
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240-Volt
- Wire size - #14-4 AWG Cu/Al at 60 degree C or 75 degree C
Circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). The Eaton Cutler-Hammer Quadplex or Quad type Circuit Breaker is designed to create (4) circuits in (2) spaces. This allows for 240-Volt circuits. The BQ style breaker has an independent trip as well as a rejection tab feature. These breakers are designed for use in BR type load centers and should be installed only in panel positions that have notched bus stabs that accommodate the rejection clip. Also, BQ circuit breakers are UL approved genuine replacement breakers for load centers made by Westinghouse, Challenger, and Bryant.
- Primary function of a circuit breaker is to protect the wire from overheating (overload) and fault currents (short circuit)
- Amperage - (1) 2 pole 20 Amp and (1) 2 pole 30 Amp
- Number of poles - 4
- Trip type - independent
- For use in type BR load centers
- Interrupt rating - 10 kAIC
- Voltage rating is 120/240V
- Wire size - #14-4 AWG Cu/Al at 60C or 75C
- Carry listing for HACR applications
- Breaker has a rejection tab feature
Eatons Type CHQ circuit breakers protect the wires in your home from overheating (referred to as an overload) and fault currents (referred to as short circuits). CHQ Breakers are classified replacement circuit breakers considered suitable, by underwriters laboratories, for use in another manufacturers" load center. These breakers have been tested extensively in QO panels. This level of testing assures that the breakers meet identified standards and have been found suitable by UL for the specified purpose.
- Contractors can streamline inventory by carrying 1 manufacturer's circuit breaker versus multiple manufacturer's
- CHQ breakers are available in 1 and 2 pole configurations
- 1 pole requires 3/4 in. space, 2 pole requires 1-1/2 in. space
- Trips to the off position